Schneider inverter ATV32 book type performance and advantages
Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; Many...
|
|
Pay attention to the problem of false load connection method in inverter debugging - Schneider
There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...
|
|
How to distinguish the authenticity of Schneider products
One. QR code scanning
Mainly for low-voltage power distribution and industrial control products produced from September 25, 2013
Method: Scan the QR code on the left side of the product anti-counterfeiting label to enter the self-service inquiry channel
Two. The official website ...
|
|
How to choose a Schneider circuit breaker?
First, calculate the value of the current of each branch
(1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...
|
|
Schneider servo drive fault code
1. AL001: overcurrent, the current value of the main 2113 circuit exceeds the motor instantaneous 5261*** high current value 1.5 times when the action is 4102.
2. AL002: overvoltage, the voltage value of the main return 1653 channel is higher than the standard value.
3. AL003: low voltage, the voltage value of the main circuit is lower than the standard.
|
|
The 7 peripherals of the inverter governor - Schneider
1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...
|
|
Inverter terminal block classification - Schneider
Inverter terminal blocks belong to a kind of connector, the variety is divided into single hole, double hole, socket, hook, etc., from the data point, copper silver plating, copper galvanized, copper, aluminum, iron, etc. Their effect is mainly to transmit electrical signals or conductive use, in the project, it is the station front engineering for the station after the project reserved for the connection ...
|
|
Input/output pins P0, P1, P2, P3 functions
P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...
|
|
Pressure reducing valves in Schneider instrumentation
A kind of pressure reducing valve in instrumentation refers to a device used to control the pressure value. Pressure reducing valves are usually used in water-related categories, because from the perspective of the transmission medium, the transmission medium of the equipment is mainly water, but we all know that water is a thing that will ...
|
|
The operation essentials of Schneider disconnectors
Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. The second is that Schneider Barrier Switches are able to work with circuit breakers to reach the point where the operation of the system is changed.
|
|
Schneider instrumentation maintenance precautions
1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...
|
|
There is no indication on the UPS boot panel that UPS is not working - Schneider
Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop:
1. Check whether the mains input wire is incinerated;
2. If the mains input is stable...
|
|
Steps for configuring braking resistors in VFD – Schneider
In the process of controlling the motor, the motor variable-frequency drive (VFD) may still have a certain kinetic energy when the motor rotates intermittently due to factors such as the moment of inertia of the motor, and the braking resistor is required to interrupt the motor.
Here's a ...
|
|
Maintenance of Schneider circuit breakers
In order to keep the main Schneider circuit breaker in excellent operating condition, it is necessary to strengthen the maintenance management.
1. Insist that the air is moist or unclean, and the pipes are not clean, may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of electric arc, which damages the ...
|
|
Maintenance and overhaul of frequency converters and soft starters
The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.
|
|
Circuit breaker breaking capacity selection - Schneider
How to choose the circuit breaker break? Rated voltage and current are the key
For professional electrical operators, the question of how to choose the circuit breaker can be said to be easy and effortless, but it is a bit difficult for novices. Circuit breaker breaking can ...
|
|
The difference between Schneider miniature circuit breaker and leakage switch
1. Definition of miniature circuit breaker
The electrical occupation is referred to as MCB, which is suitable for communicating 50/60Hz additional voltage 230/400V, additional current to 63A line overload and short circuit maintenance, and can also be used as infrequent operation conversion of the line under normal circumstances.
...
|
|
Suppression of higher harmonics of inverter - Schneider
1. About the management of higher harmonics on the output side of the inverter
The magnetic noise skills brought about by the communication harmonic components contained in the output waveform controlled by PWM control have been increasingly used in various inverters, such as the selection of higher frequency switching components, the installation of filter devices at the output end of the inverter, etc.
|
|
Schneider AC inverter usage category
Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including squirrel cage or slip ring motor, resistor, when the switch or break is generated in the motor abort, start or run...
|
|
Schneider electrical circuit control fault range
In general, depending on the phenomenon of equipment problems, the scope of the problem can be roughly confirmed as follows:
1) All button functions fail, and there is a high possibility of power supply or fuse problems.
2) Some buttons are invalid, and some of the buttons are functioning normally ...
|