In general, depending on the phenomenon of equipment problems, the scope of the problem can be roughly confirmed as follows:
1) All button functions fail, and there is a high possibility of power supply or fuse problems.
2) Some buttons are invalid, and some buttons are functioning normally. At this time, the problem is mostly in the common part of this part of the circuit or the power supply part of this part of the circuit.
3) A single button or a single function fails, and the button itself and the lead wire are more likely to cause problems.
4) Most of the problems, if it is equipment that is not used for a long time, it may be the problem of poor contact or leakage, or other problems caused by poor contact and leakage.
5) Soft problems, if there is a certain law with time or external environment, it may be that the circuit is connected with the external environment, and some functions are deteriorated and will be affected. If there is a certain relationship with the working time, the Schneider inverter is greatly affected by the temperature, which may be the deterioration of the function of the component, such as leakage, unstable function or failure caused by dirt. For example, the reversible control of a certain motor presents the problem that it cannot rotate forward, but can only rotate. Based on this feature, it is possible to confirm that the problem is in the forward control circuit, but not in the motor itself and the rotary control circuit. Press the forward button and do not let go, and then press the rotary start button, the motor does not rotate to start, which clarifies that the button interlocking function is useful, and the circuit fault is in the forward rotation control loop.
Then, following a step-by-step approach from back to front, check the forward contactor first. The coil leads are passed over the buttons and other contacts and directly connected to the power supply, and when the power is turned on, the motor rotates forward, indicating that there is no problem with the contactor. Then connect the lead wire to the start button, turn on the power, press the start button, the motor rotates forward, and the forward rotation button is clarified. There is only one dynamic breaking contact of the rotary button and the dynamic breaking contact of the rotary contactor connected in series between the forward button and the forward contactor, and the circuit has a problem, and the fault point is on the dynamic breaking contact of the rotary button and the rotary contactor, and after inspection, it is found that the dynamic breaking contact of the rotary start button can not be closed outstandingly.
|
More on that
|
Schneider inverter series at a glance
1. ATV11 series
The Schneider ATV11 series is primarily used in three-phase asynchronous motor inverters with a power range of 0.18 to 2.2 kW.
2. ATV12 series
ATV12 Schneider inverter for power scale 0.18k...
|
|
Schneider inverter fault repair
Inverter communication failure
· Fault code: SLF
Fault title: Inverter communication problem.
Cause of the failure: Communication abort on the inverter communication bus.
The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...
|
|
Deterioration site and the principle of higher harmonic generation - Schneider
1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.
|
|
Solutions to Schneider drive fault codes
PHF: 1. The power supply of the inverter is not right or the fuse is blown; 2. There is a transient problem in a certain phase. 1. Check the power connection and fuse; 2. Reset.
USF: 1. Power supply voltage undervoltage; 2. Instantaneous voltage drop; 3. The load resistor is damaged. 1 Check the power supply voltage; 2 Substitutions ...
|
|
Causes of Schneider UPS power supply damage
1. Air conditioning: It is generally forbidden to use UPS power supply, because the air conditioning is very large and belongs to the rational load.
Not suitable for belt loads
2. Motor: It is necessary to choose a large-capacity UPS power supply, because it is a rational load, and it is ...
|
|
Precautions for the installation of low-voltage electrical appliances - Schneider
1. Low-voltage electrical appliances should be equipped in a place without violent vibration, and should have an appropriate height from the ground. It is necessary to connect the power cord such as the knife switch and the load switch to the fixed contact, and it is forbidden to hang the power cord on the knife switch.
2. Low-voltage ...
|
|
Motor control mode of Schneider inverter
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Whether an AC circuit breaker can be used in a DC circuit
Schneider circuit breakers are used to open and break communication loops. The arc extinguishing of the communication system is simple, but the arc extinguishing of the DC system is more difficult. Because the system is different and the arc extinguishing principle is different, there is a big difference in structure and performance between the communication circuit breaker and the DC circuit breaker. Compared with the communication circuit breaker, the DC circuit breaker ...
|
|
Schneider Multi9 Series C120L Problem
1. What are the characteristic curves of Schneider Multi9 series C120L?
C/D curves.
2. What is the rated current level of Schneider Multi9 series C120?
63A、80A、100A、125A。
3. What is the weight of Schneider Multi9 series C120?
1P:205 ...
|
|
Inverter power settings, waveform test issues
1. After the inverter is repaired, the power number demand is corrected, don't forget
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Schneider inverter maintenance precautions
Schneider Electric intelligent special effect inverter maintenance, the daily maintenance of the inverter mainly depends on your use environment, such as moisture-proof, dust-proof, anti-foreign body ingress, pay attention to whether there is any abnormal sound when usually protecting.
Attention to the needs of inverter protection ...
|
|
Schneider UPS power supply installation steps
UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...
|
|
Troubleshooting methods in electrical circuit control - Schneider
The troubleshooting method of the electrical control line is not the same as a thousand people, and various methods can be used cooperatively, but do not copy the rigid set. In general, investigative research can help us to find out the problem. The experimental method can not only find out the fault phenomenon, but also find the fault location or fault circuit; Logic...
|
|
MiCOM P5 Series Intelligent Relay Protection Device P5 Series New Product: P5T30
MiCOM P5 Series Intelligent Relay Protection Device P5 Series New Products: P5T30 Schneider Electric Powerlogic P5 Series Transformer Differential Protection New Product P5T30 improves the gap in the differential protection of motor generators in the P5 series, making the P5 series more widely applicable.
In appearance, mechanical ...
|
|
Maintenance and overhaul of frequency converters and soft starters
The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.
|
|
Schneider circuit board maintenance work commonly used instrumentation
Before preparing to do circuit board repair work, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience has shown that prepare some necessary circuit board repair things and appearance, to be able to reach ...
|
|
Diode selection and substitution method - Schneider
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Despite the ...
|
|
Schneider instrumentation winter insulation measures
The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on.
Selection method
Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...
|
|
Schneider PLC control cabinet installation wiring method
(1) When placing signal cables with different properties into the same conduit, they must be isolated
(2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded.
...
|
|
Maintenance of multiple models of Schneider inverters
Schneider inverter our most common problem is that the power is not visible, the series of inverter switching power supply uses a UC2842 chip as a waveform generator, the damage of the chip will lead to the switching power supply can not operate, so that it can not be displayed normally, in addition, the operating power supply of the chip is not ...
|
|