How to choose a Schneider circuit breaker?

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

First, calculate the value of the current of each branch

                                 How to choose a Schneider circuit breaker?

(1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, for a 20W bulb, the branch current I=20W/220=0.09A electric fan, electric iron, electric blanket, water heater&from=forum9" target="_blank"> electric water heater, electric heater, electric rice cooker, electric wok, vacuum cleaner, air conditioner, etc. are resistive loads.

How to choose a circuit breaker is a professional technical question. Briefly, you can choose from the following 6 points: 1. The first choice is based on the additional voltage, and the additional voltage should be the same. 2. The additional current of the circuit breaker should be greater than or equal to the additional current of the circuit used. 3. The additional breaking current of the circuit breaker should be greater than or equal to the short-circuit current of the circuit used. 4. Select according to environmental conditions, such as altitude, temperature, humidity, and select circuit breakers that meet the requirements. 5. Choose a circuit breaker with high quality and cost performance according to the brand. 6. For special breaking conditions, check the circuit breaker. However, different types of circuit breakers should be used for different loads.

Principles for purchasing Schneider circuit breakers:

1. Confirm the type and maintenance method of the circuit breaker according to the maintenance requirements of the line - confirm the selection of frame type, equipment type or current limiting type, etc.

2. The additional voltage UN of the circuit breaker should be equal to or greater than the additional voltage of the line to be maintained.

3. The additional voltage of the circuit breaker undervoltage tripper should be equal to the additional voltage of the line to be maintained.

4. The additional current of the circuit breaker and the additional current of the overcurrent tripper should be greater than or equal to the calculated current of the line to be maintained.

5. The ultimate breaking capacity of the circuit breaker should be greater than the effective value of the large short-circuit current of the line.

6. The maintenance characteristics of the upper and lower circuit breakers in the distribution line should cooperate harmoniously, and the maintenance characteristics of the lower level should be located below the maintenance characteristics of the upper level and do not intersect.

7. The long-delay tripping current of the circuit breaker should be less than the continuous current promised by the wire.

After reading the above introduction of Schneider E9 and C65, you can know that these two circuit breakers have their own characteristics and advantages, so customers can buy according to their own needs, and must pay attention to the above points when purchasing, recognize the brand, and go to the regular store to buy, in order to ensure the quality of the product, and achieve safe electricity in life.
More on that
Schneider Electric executive support merger software Saas company Schneider Electric executive support merger software Saas company

MergerWare has raised an undisclosed amount of money ahead of its Series A funding round, an executive told TechCircle. The Company provides software solutions to help integrate mergers and acquisitions-related businesses. The funding came from electrical equipment manufacturer Schneider Electric (Schneider ...

Schneider servo motor advantages Schneider servo motor advantages

Schneider servo motor is one of the brands of servo motor, the performance is relatively good, is a brand made in Germany, in China ** degree is relatively high. Servo motor refers to the servo system, (servomechanism) in which the mechanical components are controlled.

The 7 peripherals of the inverter governor - Schneider The 7 peripherals of the inverter governor - Schneider

1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...

Schneider seizes the opportunity of e-commerce Schneider seizes the opportunity of e-commerce

Beijing, China, 24 August 2021 – Looking at the history of the logistics industry, the changes brought about by the development of e-commerce in recent years are rare. According to Digital Commerce 360, in 2020, United States customers spent $861.12 billion online, a year-on-year increase.

Schneider inverter debugging steps and brief description Schneider inverter debugging steps and brief description

Commissioning process of the Schneider 61 series 1. Preparations 1. Measure insulation. Connect the power supply side (R.S.T) and the motor side (U.V.W) of the inverter Disconnect the cable, insulate the cable with a 500 megaohm or 1000 megaohm shake meter, and if it meets the requirements, restore it.

Introduction to the core knowledge and application of instrumentation - Schneider Introduction to the core knowledge and application of instrumentation - Schneider

Although the "measurement and control skills and instruments" category of majors touch the fields of national defense, aerospace, aviation, sailing, railway, machinery, light industry, chemical industry, electronics, electric power, telecommunications, metallurgy, petroleum, mining, geology, surveying and other industrial, agricultural and scientific research categories, the Ministry of Education has a special understanding of "measurement and control skills and instruments".

Schneider UPS power supply installation precautions Schneider UPS power supply installation precautions

The quality of UPS power supply devices directly affects the long-term operation of the UPS system in the future, especially the large and medium-sized UPS power supplies, so the large and medium-sized UPS power supplies should be standard in the process of planning to the device. Generally speaking, UPS power supply ...

Schneider drives copy replication parameters Schneider drives copy replication parameters

1. Copy and copy through the Chinese panel. Older inverters, if they support Chinese panels, such as ATV71, ATV61, etc., support VW3A1101 panels, they can use the proprietary 'open/save as' parameter on the panel to copy and copy, and the newer ATV610, ATV630, ATV930, ...

Schneider introduces the new Lexium28S servo Schneider introduces the new Lexium28S servo

The newly launched Lexium28S Sercos III bus servo with BCH2 servo motor is available as a pre-order product portfolio to meet the needs of motion control and optimize the function of the machine. Lexium28S servo drives, available in 4 sizes, 10 models, power mask 0.05KW to 4 ...

Dual-fan inverter selection - Schneider Dual-fan inverter selection - Schneider

1. Qualified after inspection When selecting a double fan inverter, it must be strictly checked for its quality. The first requirement is that it must have relevant certificates of qualified inspection, and some qualified materials must be taken out. This is the only way to ensure that this change ...

Schneider soft starter fault alarm maintenance method Schneider soft starter fault alarm maintenance method

1. Question-F 05 (frequency error): This problem is caused by a problem with the soft starter processing the internal power signal, which is causing errors in the power supply frequency. This situation needs to be handled by the company's product development software design engineer. Mainly start the power supply circuit design ...

The operation essentials of Schneider disconnectors The operation essentials of Schneider disconnectors

Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it is able to disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. Secondly, the Schneider barrier switch can be used with the circuit breaker to change the operation of the system.

Schneider PLC signal light meaning Schneider PLC signal light meaning

Take the Schneider PLC with model number TWDLCAA40DRF as an example: The first PWR: is the meaning of power supply; The second RUN: is the PLC operation indicator; Long dark: The application is not fulfilling; Shine: The controller is in a stay or a mistake in performance; Solid on: The controller is in operation ...

Schneider medium-voltage inverters focus on energy saving Schneider medium-voltage inverters focus on energy saving

Because the impact of foreign electrical products on domestic electrical equipment is relatively large, now Schneider inverter equipment occupation is facing a big technical promotion, taking inverter as an example, the national connotation of inverter shopping mall domestic brand and foreign brand, regardless of technology, processing and manufacturing, industrial design and other aspects are still ...

Is there still an output after the UPS power is turned off? Is there still an output after the UPS power is turned off?

1. After the UPS power supply is shut down, the output terminal is still powered, but the UPS power supply does not play a role at this time, and it is in a bypass state. 2. The power supply will not be cut off after the UPS power supply is shut down, because the UPS power supply will go bypass after the shutdown, there is still a mains power input at this time, ...

Safety PLC is different from ordinary PLC Safety PLC is different from ordinary PLC

A safety PLC differs from conventional PLCs in that it needs to be certified for safety by a third-party professional organization and meet stringent international standards for safety and reliability. There is a need for a thorough systematic approach to the planning and testing of safety PLCs. TUV*** in Germany and FM*** in United States ...

Schneider inverter ATV61 OPF failure analysis Schneider inverter ATV61 OPF failure analysis

Q: 250KW ATV61 with 250KW fan, when decelerating to low speed, OPF (motor missing three-phase) problem will be reported occasionally. There are no contactors or switches between the inverter and the motor. Answer: This situation seems to be a problem with the inverter, which is a false alarm. Not really! The fan is decelerating ...

Precautions for setting parameters of Schneider inverter Precautions for setting parameters of Schneider inverter

 Debugging parameters: ​ 1. Acceleration and deceleration time Speed up the time setting requirements: the acceleration current is constrained below the overcurrent capacity of the inverter, so that the overflow will not cause the inverter to trip; Deceleration time setting key ...

Schneider appeared at the 5th China Power Distribution Technology Summit Forum Schneider appeared at the 5th China Power Distribution Technology Summit Forum

Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...

How Schneider UPS properly configures the backup battery How Schneider UPS properly configures the backup battery

In order to ensure that the APCUPS power supply can continue to supply high-quality power to the computer even in the event of a power outage, it is important to equip the battery backup battery. When the load is not allowed to be powered, the UPS battery backup time in the communication room should be greater than the time from the mains power interruption to the rehabilitation or to the generator set is positive.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top