AC-DC inverter composition and function - Schneider
The AC-DC inverter main circuit consists of three components: the rectifier main circuit, the center circuit and the inverter circuit.
1. The main circuit is the power replacement part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the voltage source ...
|
|
Inverter selection principle - Schneider
1. Select the inverter according to the load characteristics.
2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.
|
|
Is there a restriction on the installation direction when Schneider installs the inverter?
It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large in size, takes up a lot of space, and the cost is higher. This can be done by:
(1) The planning of the disc should be based on the heat dissipation required by the actual device;
(2) Profit ...
|
|
Common maintenance problems for Schneider drives
1. Why is the inverter used for fan and pump loads to save energy?
According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...
|
|
The operation essentials of Schneider disconnectors
Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. The second is that Schneider Barrier Switches are able to work with circuit breakers to reach the point where the operation of the system is changed.
|
|
Schneider inverter control circuit
1. What is a control loop?
The network that supplies the control signal to the main circuit that supplies power to the asynchronous motor (voltage and frequency can be adjusted) is called the control loop.
Second, the composition of the control loop
The control circuit is controlled by the frequency ...
|
|
Schneider AC contactor precautions
There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A
When installing, it should be in accordance with the regulations...
|
|
Schneider circuit breaker technical issues
1. Overload maintenance failure: The circuit breaker should be tripped for maintenance when the current exceeds the rated current, but sometimes the overload maintenance failure may be due to some reasons. This may be due to incorrect overload maintenance settings, long overload periods, thermal aging due to successive overloads, etc.
2 ...
|
|
Schneider inverter simple question
1. How to complete the control of ATV38 and ATV58 through the operation panel?
First, in the control menu, set "LCC" to "YES" (panel operation); Enter the "LFR" parameter in the adjustment menu, press the up and down keys to adjust the given value, and complete the control of the inverter.
...
|
|
Inverter selection and capacity matching - Schneider
In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate.
...
|
|
Frequency converter and PLC connection problems - Schneider
When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1.PLC switch ...
|
|
Schneider disconnector operation inspection content and requirements
(1) Whether the closing of the barrier switch is defective, whether there is no failure or dislocation;
(2) The porcelain insulation of the barrier switch should be free of cracks, discharge phenomena and flashover traces;
(3), contact viewing: a, view ...
|
|
Schneider inverter enters the parameter setting method
1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct
2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification
3. Next, set the function parameters to launch the ...
|
|
Schneider servo model introduction
LXM23DU01M3X servo drive 0.1 kW
LXM23DU02M3X servo drive 0.2 kW
LXM23DU04M3X Servo drive 0.4 kW
LXM23DU07M3X Servo drive 0.75 kW
LXM23DU10M3X ...
|
|
The method of controlling the speed of the motor by the inverter - Schneider
1. Why can the rotation speed of the motor be changed freely?
Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm.
Example: 2-pole motor 50Hz 3000 [r/min]
4-pole motor 50Hz 1500 [r/min]
Conclusion:...
|
|
Schneider miniature circuit breaker code calling
Schneider miniature circuit breaker code marking method
For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is:
1--------- identification number
C65 ------ serial code
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
Analysis of 10 reasons for frequent tripping of Schneider leakage switches
1. Defective device
If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action.
2. Leakage switch with ...
|
|
Schneider inverter external potentiometer connection
The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
Schneider medium-voltage inverters focus on energy saving
Because the impact of foreign electrical products on domestic electrical equipment is relatively large, now Schneider inverter equipment occupation is facing a big technical promotion, taking inverter as an example, the national connotation of inverter shopping mall domestic brand and foreign brand, regardless of technology, processing and manufacturing, industrial design and other aspects are still ...
|
|
Advantages and disadvantages of closed busbars compared with open busbars - Schneider
The advantages of closed busbars over open busbars are:
1) Closing the bus duct can reduce the grounding fault, avoid the short circuit between phases, basically eliminate the grounding defect caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate ...
|