Schneider instrumentation maintenance precautions

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets.

                                 Schneider instrumentation maintenance precautions

2. Do not plug and unplug various control boards and plugs with electricity. Because in the power-on condition, plugging and unplugging the control board will produce a strong induced electromotive force, and the instantaneous counterattack voltage is very high, and it is very simple to damage the corresponding control board and plug.

3. When using a logic pen and oscilloscope to detect the signal, be careful not to make the probe touch the two measurement pins at the same time, because the essence of this situation is to form a short circuit under the condition of power-on.

4. When disassembling and adjusting the instrument, the original orientation should be recorded for restoration.

5. When detecting the filter capacitor in the power supply, the positive and negative poles of the electrolytic capacitor should be short-circuited first, and do not use the meter pen wire to replace the wire to discharge the capacitor when the short circuit is short-circuited. You can take a 220V, 60-100W lamp with a lamp head lead, connect it to both ends of the capacitor, and the bulb will flash at the moment of discharge.

6. When repairing instrument failures in a humid environment, it is necessary to use a multimeter to measure whether each point of the printed circuit is clear, because the main fault in this situation is copper foil corrosion.

7. When overhauling the internal circuit of the instrument, if the contacts of the device components and the circuit board are coated with insulating varnish, the parameters of each point can be welded to the table pen of the multimeter with a general hand-sewn needle, so as to pierce the paint layer and directly measure each point, without having to peel off the paint layer in a large area.

8. When using a multimeter ohm, remember not to measure with electricity.

9. When repairing precision instruments, if you accidentally bounce small parts away, you should first identify the place that may fly down, do not look for it in the east or turn it in the west, you can take magnet scanning and field of view scanning methods to find.

In short, in the maintenance of instrumentation, first of all, we should understand the basic principles of instrumentation, and master the knowledge and skills related to electronics, and should prepare all the technical information such as manuals and drawings of instrumentation, and should develop a good working essence, so as to improve efficiency and reduce errors in the maintenance of instrumentation.

More on that
Methods to reduce the interference of Schneider inverters themselves Methods to reduce the interference of Schneider inverters themselves

When there are high-frequency impact loads such as welding machines, electroplating power supplies, electrolytic power supplies, or slip ring power supply near the power supply system of Schneider inverter, the inverter itself is simply protected due to interference. It is recommended that users choose the following methods: ...

Inverter braking resistor selection – Schneider Inverter braking resistor selection – Schneider

In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...

Introduction to Schneider inverter inverter Introduction to Schneider inverter inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to a certain law, and the motor strictly follows the dynamic and stop command action of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Schneider online UPS power supply is energy-saving Schneider online UPS power supply is energy-saving

1. The need for stability When choosing UPS products, the customer's focus must be stability. For UPS, higher power means lower calorific value. Of course, only one of the primary factors that affect the internal temperature of the UPS is also to consider the heat dissipation planning of the machine itself. ...

Schneider UPS power supply preventive maintenance precautions Schneider UPS power supply preventive maintenance precautions

1 Contingency plan Contingency plans are the top priority of preventive protection. Arrangements need to be better partnered with service providers to be part of the corporate programme. This means implementing processes and procedures for every type of thing, including contingency plans. ...

Schneider ATV610 inverter applications Schneider ATV610 inverter applications

The Schneider ATV610 inverter is suitable for specification loads and can be used in a wide range of industries and infrastructure. Including: petrochemical, power plant, industrial and civil buildings, water treatment and sewage treatment, HVAC, thermal heating, constant pressure water supply, and other applicable occasions. In these jobs ...

Schneider relay model introduction Schneider relay model introduction

RM4 Series Control Relay (Three-phase Power Control) RM4 series voltage steerable relays RM4 current operated relay RM4 level control relay RM17 three-phase power controller RM35 3-phase power control relay RM17 Voltage Steerable Relay ...

Schneider Instrumentation Classification Standard Schneider Instrumentation Classification Standard

The classification specifications for the appearance of the instrument are as follows: The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, and a variety of classification methods. According to the purpose and use of the use of the main measuring instrument, car appearance, tractor appearance, marine ...

Schneider UPS power supply installation precautions Schneider UPS power supply installation precautions

The quality of UPS power supply devices directly affects the long-term operation of the UPS system in the future, especially the large and medium-sized UPS power supplies, so the large and medium-sized UPS power supplies should be standard in the process of planning to the device. Generally speaking, UPS power supply ...

Dual-fan inverter selection - Schneider Dual-fan inverter selection - Schneider

1. Qualified after inspection When selecting a double fan inverter, it must be strictly checked for its quality. The first requirement is that it must have relevant certificates of qualified inspection, and some qualified materials must be taken out. This is the only way to ensure that this change ...

How Schneider UPS properly configures the backup battery How Schneider UPS properly configures the backup battery

In order to ensure that the APCUPS power supply can continue to supply high-quality power to the computer even in the event of a power outage, it is important to equip the battery backup battery. When the load is not allowed to be powered, the UPS battery backup time in the communication room should be greater than the time from the mains power interruption to the rehabilitation or to the generator set is positive.

Precautions for motor operation over 60Hz - Schneider Precautions for motor operation over 60Hz - Schneider

What problems should be paid attention to when the motor works beyond 60Hz? The following precautions should be taken when operating beyond 60Hz (1) Machinery and equipment should have sufficient potential to work at this speed (mechanical strength, noise, vibration, etc.). (2) ...

The meaning of the inching of Schneider inverter The meaning of the inching of Schneider inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to the certain rules, and the motor acts in strict accordance with the dynamic and stop instructions of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Analysis of 10 reasons for frequent tripping of Schneider leakage switches Analysis of 10 reasons for frequent tripping of Schneider leakage switches

1. Defective device If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action. 2. Leakage switch with ...

Features of Schneider explosion-proof inverter boxes Features of Schneider explosion-proof inverter boxes

1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; ​ 3. It mainly regulates the general three-phase difference by changing its output frequency.

Schneider Electric executive support merger software Saas company Schneider Electric executive support merger software Saas company

MergerWare has raised an undisclosed amount of money ahead of its Series A funding round, an executive told TechCircle. The Company provides software solutions to help integrate mergers and acquisitions-related businesses. The funding came from electrical equipment manufacturer Schneider Electric (Schneider ...

Advantages of Schneider molded case circuit breaker Advantages of Schneider molded case circuit breaker

The contact orientation is 100% secure As for the circuit breaker, the indication of the handle can also be said to be the fault indicator of the circuit breaker, if it is "blurred" for a while, it may cause irreparable damage. Therefore, according to the requirements of the national standard, in any case, the hand of the circuit breaker ...

Schneider circuit breaker technical issues Schneider circuit breaker technical issues

1. Overload maintenance failure: The circuit breaker should be tripped for maintenance when the current exceeds the rated current, but sometimes the overload maintenance failure may be due to some reasons. This may be due to incorrect overload maintenance settings, long overload periods, thermal aging due to successive overloads, etc. 2 ...

Maintenance of multiple models of Schneider inverters Maintenance of multiple models of Schneider inverters

Schneider inverter our most common problem is that the power is not visible, the series of inverter switching power supply uses a UC2842 chip as a waveform generator, the damage of the chip will lead to the switching power supply can not operate, so that it can not be displayed normally, in addition, the operating power supply of the chip is not ...

Input/output pins P0, P1, P2, P3 functions Input/output pins P0, P1, P2, P3 functions

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top