Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; A variety of friendly dialogue tools, which can upload and download parameters when the power is off; Built-in CANopen and Modbus, support a variety of industrial communication protocols; Built-in Bluetooth communication, remote debugging through mobile phone.
performance
200 V… 240 V single-phase, 0.18 kW to 2.2 kW (ATV 32H... M2)
380 V… 500 V three-phase, 0.37 kW to 15 kW (ATV 32H... N4)
advantage
Built-in programmable controller function, flexible and intelligent
Integrated safety functions provide up to 30% cost savings compared to external security modules
Best-in-class Schneider Electric patented open-loop control technology for synchronous motors
Book-type design, support side-by-side close installation, space-saving
A variety of friendly dialogue tools, which can upload and download parameters when the power is off
Built-in CANopen and Modbus, supporting a variety of industrial communication protocols
Built-in Bluetooth communication, remote debugging through mobile phone
More innovations
Book-shaped design, only 45mm wide
Flexible installation, side-by-side, side-by-side or direct circuit breaker mounting
Built-in Bluetooth ®: Can be remotely debugged using a PC or mobile phone
With a multi-function downloader, parameters can be downloaded without powering up
Built-in simple programmable logic functions
Safer
Multiple safety functions are available as standard
STO (Safe Undo Torque)
SLS (Safely Limited)
SS1 (Safe Shutdown 1)
More open
Built-in Modbus and CANopen, plug in the corresponding cassette communication card to support a variety of communication protocols:
CANopen daisy-chain (easy to daisy-chain the inverter)
EtherNet/IP - Modbus TCP (dual port)
Profibus
DeviceNet
Sharing of the tool platform with other Schneider Electric product families to meet various customer needs (wiring, programming, operation)
The remote graphic display terminal is convenient for remote debugging
With the multi-function downloader, parameters can be stored or downloaded quickly without powering up the drive
The simple downloader makes it easy to copy and download individual parameter configurations
The SoMove software is used to configure the parameters on the PC and transmit them via cable or Bluetooth
The SoMove Mobile software is used to modify or send parameter configurations remotely via mobile phone
|
More on that
|
Dual-fan inverter selection - Schneider
1. Qualified after inspection
When selecting a double fan inverter, it must be strictly checked for its quality. The first requirement is that it must have relevant certificates of qualified inspection, and some qualified materials must be taken out. This is the only way to ensure that this change ...
|
|
Detailed explanation of the steps of Schneider inverter inverter setup
1. Macro equipment:
In view of the control requirements of different loads, Schneider inverters have talked about the macro equipment in advance and the initial function of the I/O terminals.
Changes to the macro rig can be corrected under the Abbreviated Boot Menu.
If required, it is also possible to re-equip the end separately ...
|
|
How Schneider UPS properly configures the backup battery
In order to ensure that the APCUPS power supply can continue to supply high-quality power to the computer even in the event of a power outage, it is important to equip the battery backup battery. When the load is not allowed to be powered, the UPS battery backup time in the communication room should be greater than the time from the mains power interruption to the rehabilitation or to the generator set is positive.
|
|
Advantages of the Schneider Magelis GXU touchscreen
1. Save capital contribution
Focus on central function (true color LCD, serial communication interface, USB connection, Ethernet interface, etc.)
2. Save space
Compact structure planning, only 38mm thick
The fuselage is reserved for communication wiring ...
|
|
Safety PLC is different from ordinary PLC
A safety PLC differs from conventional PLCs in that it needs to be certified for safety by a third-party professional organization and meet stringent international standards for safety and reliability. There is a need for a thorough systematic approach to the planning and testing of safety PLCs. TUV*** in Germany and FM*** in United States ...
|
|
Schneider PLC control cabinet installation wiring method
(1) When placing signal cables with different properties into the same conduit, they must be isolated
(2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded.
...
|
|
Technical causes of Schneider low-voltage circuit breaker accidents
(1) Operational failure
Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the fundamental and important function of the high-voltage circuit breaker is to act correctly and quickly remove the fault of the power grid. If the circuit breaker is dragged or misoperated, it will pose a serious threat to the power grid, first of all: (1) expansion ...
|
|
Schneider inverter frequently asked questions
1. Schneider inverter uses analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA?
Answer: Because of the large output frequency parameter "TFR" of the inverter, the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is ...
|
|
Instrumentation overhaul points - Schneider
The test input does not conform to the "short" rule, and the problem is here.
1. Overhaul according to the comparator rules, fit it, the piece is good, and check the periphery; It doesn't fit, the piece is bad.
2. It does not fit the "virtual break" - there are ...
|
|
The energy-saving effect of using frequency converter for fan and pump loads
Why is the use of inverter for fan and pump loads to save energy?
According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...
|
|
Schneider touch screen touch deviation causes
(1) Problem--: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye center when calibrating the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: Some districts ...
|
|
Schneider selection of different types of circuit breakers
Schneider miniature circuit breakers are:
A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc
Schneider molded case circuit breakers are:
NSX, NSE, EZD, NSC, large plastic case NS
Schneider structural circuit breakers have ...
|
|
Schneider low-voltage circuit breaker selection
1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the Schneider frame circuit breaker can break the short-circuit current with a large device type and a large volume. Usually, the branch line chooses ...
|
|
Schneider's small PLC part model
Schneider has M100/M200 for small programmable controllers, and M340 and M580 for medium and large programmable controllers
The compact M100 model is available in TM100C24RN, TM100C32RN, and TM100C40RN.
Small M200 ...
|
|
Schneider Electric has announced a partnership with RMSI
Schneider Electric has named RMSI North America, an IT services company that provides geospatial and software solutions, as an ArcFM Specialty Partner. RMSI is well positioned to provide GIS solutions for utilities and telecommunications companies across the entire geospatial value chain...
|
|
Precautions for the selection of Schneider molded case circuit breaker
1. Shell current and rated current
The size of the shell current is 100 (rated current 16 25 32 40 63 80 100) 250 (rated current 160 250 400 (rated current 250 400) 630 (rated current 630A.)
...
|
|
Inverter braking resistor selection – Schneider
In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...
|
|
Is there still an output after the UPS power is turned off?
1. After the UPS power supply is shut down, the output terminal is still powered, but the UPS power supply does not play a role at this time, and it is in a bypass state.
2. The power supply will not be cut off after the UPS power supply is shut down, because the UPS power supply will go bypass after the shutdown, there is still a mains power input at this time, ...
|
|
Schneider online UPS power supply is energy-saving
1. The need for stability
When choosing UPS products, the customer's focus must be stability. For UPS, higher power means lower calorific value. Of course, only one of the primary factors that affect the internal temperature of the UPS is also to consider the heat dissipation planning of the machine itself.
...
|
|
THE DIFFERENCE BETWEEN SCHNEIDER CIRCUIT BREAKER EASYPACT AND MASTERPACT
First of all, both are low-voltage circuit breakers (below 1000V)
Let's start with Schneider Masterpact, which is a structural circuit breaker. The current rating of the structure varies from 800A ---- 6300A. The Masterpact series is divided into M series and MT series. The M series has been on the market since 1986 and was screened and delisted in 2002.
|
|