Schneider servo drive fault code

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. AL001: overcurrent, the current value of the main 2113 circuit exceeds the motor instantaneous 5261*** high current value 1.5 times when the action is 4102.

2. AL002: overvoltage, the voltage value of the main return 1653 channel is higher than the standard value.

3. AL003: low voltage, when the voltage value of the main circuit is lower than the standard voltage.

                               Schneider servo drive fault code

4. AL004: The motor matching is abnormal, and the motor corresponding to the driver is wrong.

5. AL005: Abnormal rebirth, rebirth control action when abnormal movement.

6. AL006: overload, action when the motor and driver are overloaded.

7. AL007: overspeed, when the motor control speed exceeds the normal speed and is too large.

8. Motor error counter overflow error when rotating at high speed: check whether the wiring of the motor power cable and encoder cable is correct, whether the cable is damaged, and the motor error counter overflow error occurs when entering a long command pulse, and the gain setting is too large, and the gain is manually adjusted from the beginning or the gain adjustment function is used

More on that
Causes of Schneider UPS power supply damage Causes of Schneider UPS power supply damage

1. Air conditioning: It is generally forbidden to use UPS power supply, because the air conditioning is very large and belongs to the rational load. Not suitable for belt loads 2. Motor: It is necessary to choose a large-capacity UPS power supply, because it is a rational load, and it is ...

Inverter braking resistor selection – Schneider Inverter braking resistor selection – Schneider

In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...

Schneider servo motor advantages Schneider servo motor advantages

Schneider servo motor is one of the brands of servo motor, the performance is relatively good, is a brand made in Germany, in China ** degree is relatively high. Servo motor refers to the servo system, (servomechanism) in which the mechanical components are controlled.

Schneider XPS safety control module selection method Schneider XPS safety control module selection method

(1) Evaluate the safety control level that the machinery and equipment need to reach (2) Confirm the type of input signal to be monitored and (3) the number of input signals that need to be monitored (4) The number and type of channels that the module needs to output (5) Whether it is necessary to control the output device (such as ...

Key points of operation of Schneider disconnectors Key points of operation of Schneider disconnectors

Features of Schneider Barrier Switch: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and can also see the obvious disconnection point on it. Secondly, Schneider barrier switches can cooperate with circuit breakers to change the operation of the system.

Whether an AC circuit breaker can be used in a DC circuit Whether an AC circuit breaker can be used in a DC circuit

Schneider circuit breakers are used to open and break communication loops. The arc extinguishing of the communication system is simple, but the arc extinguishing of the DC system is more difficult. Because the system is different and the arc extinguishing principle is different, there is a big difference in structure and performance between the communication circuit breaker and the DC circuit breaker. Compared with the communication circuit breaker, the DC circuit breaker ...

Schneider circuit breaker maintenance Schneider circuit breaker maintenance

1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences: (1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of the arc, and the insulation between the fractures after the main contact is broken is destroyed.

Precautions for Schneider to use USP power supplies Precautions for Schneider to use USP power supplies

(1) When using Schneider UPS power supply, the relevant provisions of the manufacturer's product manual should be strictly adhered to ensure that the front and zero line sequences of the mains connected by Schneider UPS meet the requirements. (2) The main intention of equipping Schneider UPS is to prevent the computer from losing information due to a sudden power failure...

Analysis of the reasons why the contact of Schneider contactor is not reliable Analysis of the reasons why the contact of Schneider contactor is not reliable

The unreliable contact touch will increase the touch resistance between the dynamic and static contacts, resulting in the high temperature of the touch surface, making the surface touch become a point touch, and even showing a non-conduction phenomenon. The reasons for this failure are: (1) There are ...

The protection function of the inverter - Schneider The protection function of the inverter - Schneider

Protective functions can be divided into the following two categories: (1) After detecting the abnormal situation, the correction action is automatically carried out, such as overcurrent loss speed avoidance, regeneration overvoltage stall avoidance. (2) After detecting the abnormality, the PWM control signal of the power semiconductor equipment is closed, so that the motor automatically stops. As...

Schneider ATV312 inverter failure Schneider ATV312 inverter failure

1. OLF is motor overload. Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong. Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...

Schneider seizes the opportunity of e-commerce Schneider seizes the opportunity of e-commerce

Beijing, China, 24 August 2021 – Looking at the history of the logistics industry, the changes brought about by the development of e-commerce in recent years are rare. According to Digital Commerce 360, in 2020, United States customers spent $861.12 billion online, a year-on-year increase.

Is there a restriction on the installation direction when Schneider installs the inverter? Is there a restriction on the installation direction when Schneider installs the inverter?

It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large, takes up a lot of space, and the cost is relatively high. This can be done by: (1) The planning of the disc should be based on the heat dissipation required by the actual device; (2) Profit ...

Schneider Electric miniature circuit breaker accident prevention Schneider Electric miniature circuit breaker accident prevention

With the development of the electric power industry, now the electricity has been accompanied by every detail of our days, so the maintenance of the electric power industry, began to get more and more attention from everyone, because the circuit in the daily operation side, very simple because of overvoltage or undervoltage and present a certain problem, which ...

Inverter selection principle - Schneider Inverter selection principle - Schneider

1. Select the inverter according to the load characteristics. 2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.

Schneider Electric Innovation Summit "The future is digital" Schneider Electric Innovation Summit "The future is digital"

The name of a company's product was mentioned more than anyone could remember, but on the first day of the Schneider Electric North America Innovation Summit in Atlanta on Tuesday, another word appeared even more often ...

The meaning of the inching of Schneider inverter The meaning of the inching of Schneider inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to the certain rules, and the motor acts in strict accordance with the dynamic and stop instructions of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Steps for configuring braking resistors in VFD – Schneider Steps for configuring braking resistors in VFD – Schneider

In the process of controlling the motor, the motor variable-frequency drive (VFD) may still have a certain kinetic energy when the motor rotates intermittently due to factors such as the moment of inertia of the motor, and the braking resistor is required to interrupt the motor. Here's a ...

Schneider instruments measure error factors Schneider instruments measure error factors

When measuring, because various elements will constitute a small number of errors, these elements need to be understood and effectively solved, so that the errors in the whole measurement process can be reduced to the smallest. When measuring, the main errors that constitute errors are system errors and random errors, and system errors have the following conditions: misreading, ...

Schneider inverter enters the parameter setting method Schneider inverter enters the parameter setting method

1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct 2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification 3. Next, set the function parameters to launch the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top