Schneider AC inverter usage category

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including the type of switch that the load is turned on, including the squirrel cage or slip ring motor, resistor, when the switch on or break is in the motor stop, start or run, as well as reverse, reverse braking, etc., the specific communication application categories are as follows:

                               Schneider AC inverter usage category

1. The AC-1 category of communication contactor is mainly applicable to all communication loads with power factor exceeding class 0.95, such as heating, lighting, power distribution, etc.

2. The AC-2 category is mainly suitable for the starting, reverse braking and inch movement of the slip ring electromechanical, and the starting current of the Schneider communication contactor is turned on when the closing action is performed, which is about 2.5 times the additional current of the motor. At the time of the performance of the breaking action, the contactor must break the starting current, and in the case of voltage less than or equal to the main power supply, such as in some lifting occupations.

3. The application category of AC-3 communication contactor is usually to break the effect of the normally starting squirrel cage motor, and when closed, the contactor will perform the action of turning on the starting current, which can carry about 7 times the additional current of the motor together. When it is disconnected, it can break the additional current of the motor, and the voltage value on the terminal of the communication contactor at this time will be about 20% of the main power supply, and it can be used in squirrel cage motors, air compressors, air conditioners, escalators, conveyor belts, mixers and excavators.

4. AC-4 application category can play the effect of reverse braking and inching of squirrel cage or slip ring motor, Schneider communication contactor can be connected to about 5 to 7 times of the additional motor current, and can break the same current value at higher voltage, when the motor speed is lower, the voltage will be as severe as the main voltage, usually suitable for printing machinery, metallurgical occupations, wire drawing machines, lifting and tower cranes.
  
More on that
Schneider UPS uninterruptible power supply debugging precautions Schneider UPS uninterruptible power supply debugging precautions

1. Check whether all switches are in the disconnected position; 2. Check whether there are foreign objects in the UPS uninterruptible power supply cabinet and transformer; Check whether the flat cable connection is correct and whether it is loose; 3. Check that the connected plug is ...

The protection function of the inverter - Schneider The protection function of the inverter - Schneider

Protective functions can be divided into the following two categories: (1) After detecting the abnormal situation, the correction action is automatically carried out, such as overcurrent loss speed avoidance, regeneration overvoltage stall avoidance. (2) After detecting the abnormality, the PWM control signal of the power semiconductor equipment is closed, so that the motor automatically stops. As...

Schneider instrumentation accuracy Schneider instrumentation accuracy

It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...

The difference between the highest frequency and the basic frequency of the inverter - Schneider The difference between the highest frequency and the basic frequency of the inverter - Schneider

1. There are two ways to say the fundamental frequency: (1) The frequency corresponding to the maximum output voltage of the inverter is called the fundamental frequency; (2) When the output voltage of the inverter is equal to the additional voltage, the minimum output frequency is called the fundamental frequency. The fundamental frequency is expressed in fBA. ...

Inverter selection principle - Schneider Inverter selection principle - Schneider

1. Select the inverter according to the load characteristics. 2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.

Inverter control motor speed method - Schneider Inverter control motor speed method - Schneider

1. Why can the rotation speed of the motor be changed freely? Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz 3000 [r/min] 4-pole motor 50Hz 1500 [r/min] Conclusion:...

Calculation method of inverter capacity - Schneider Calculation method of inverter capacity - Schneider

1. Accounting of inverter capacity when the load is continuously changed periodically In many cases, the load of the motor changes periodically. Obviously, in this case, picking the capacity of the inverter according to the minimum load will be overloaded, and it will be uneconomical to select according to the maximum load.

Common maintenance problems for Schneider drives Common maintenance problems for Schneider drives

1. Why is the inverter used for fan and pump loads to save energy? According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...

A brief description of the working principle of Schneider power soft starter A brief description of the working principle of Schneider power soft starter

Schneider ATS48 soft starter is composed of three opposite parallel thyristors, which are connected in series between the three-phase power supply and the motor, by changing the trigger angle of the thyristor gate pulse, the conduction angle of the thyristor gradually increases from zero, according to the pre-set soft starter parameter curve, the motor output torque ...

The form of power input and output - Schneider The form of power input and output - Schneider

1. Single-phase input/single-phase output: If the capacity is relatively small, the single-entry UPS hanging on any phase of the mains will not be troublesome to the three-way distribution balance of the mains, the load capacity is small, and the output line diameter (current value) of the single-phase output is not ...

Introduction of Schneider Electric three-phase uninterruptible power supply Introduction of Schneider Electric three-phase uninterruptible power supply

Sensitive operation form, satisfactory business operation policy: Four-level inverter technology: Galaxy VX uses innovative patented four-level inverter technology to reduce power consumption and pressure on power components, and complete the perfect unity of high power and component reliability. Sensitive operating form ...

There is a remote code execution vulnerability in Schneider industrial equipment There is a remote code execution vulnerability in Schneider industrial equipment

Recently, Armis security researchers have reported that Schneider Electric's programmable logic manipulators (PLCs) have serious and unpatched gaps in long-distance code fulfillment, allowing intruders to manipulate their various industrial systems. Schneider ...

Line leakage detection method - Schneider Line leakage detection method - Schneider

Line leakage detection method, leakage check method summary, if a closing, leakage switch will trip, this kind of front leakage, check the method is as follows: 1. Disconnect all the separation gates, close the main gate, close the separation gates one by one, and close them to ...

Features of Schneider elliptical gear flowmeter Features of Schneider elliptical gear flowmeter

Elliptical gear flowmeter (also known as displacement flowmeter, gear flowmeter), classified as a positive displacement flowmeter, is a class with high accuracy in the flow surface. It uses a mechanical measuring element to continuously cut the fluid into a single known volume part, and according to the measuring chamber, it is repeated and repeated.

Common faults and judgments of Schneider inverters and controllers Common faults and judgments of Schneider inverters and controllers

Reducing power consumption is also a key point reflected, because Taiwan imports power proportion of 99%, improve power efficiency, comprehensive development of power transformation is the absolute direction, in the future Schneider each new product will also buckle the two major tones of energy saving and intelligence, in the words quite Schneider to from the power expert identity ...

Introduction to the core knowledge and application of instrumentation - Schneider Introduction to the core knowledge and application of instrumentation - Schneider

Although the "measurement and control skills and instruments" category of majors touch the fields of national defense, aerospace, aviation, sailing, railway, machinery, light industry, chemical industry, electronics, electric power, telecommunications, metallurgy, petroleum, mining, geology, surveying and other industrial, agricultural and scientific research categories, the Ministry of Education has a special understanding of "measurement and control skills and instruments".

Detailed explanation of the steps of Schneider inverter inverter setup Detailed explanation of the steps of Schneider inverter inverter setup

1. Macro equipment: In view of the control requirements of different loads, Schneider inverters have talked about the macro equipment in advance and the initial function of the I/O terminals. Changes to the macro rig can be corrected under the Abbreviated Boot Menu. If required, it is also possible to re-equip the end separately ...

Schneider circuit breakers, contactors, thermal relays selection Schneider circuit breakers, contactors, thermal relays selection

In daily work, the combination of circuit breaker, contactor and thermal relay is the most common combination of motor power supply circuit, and the circuit breaker is generally the short-circuit instantaneous action of magnetic maintenance, the contactor realizes relay logic control, and the thermal relay overload maintenance. The parameter selection method of these three kinds of gas parts is as follows: ( ...

The ultimate short-circuit breaking capacity of Schneider circuit breakers The ultimate short-circuit breaking capacity of Schneider circuit breakers

The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...

Schneider automatic control instrument construction content and procedures Schneider automatic control instrument construction content and procedures

1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed design documents), construction organization design, equipment list, data budget, and list of machined parts; 2. Cooperate with civil engineering majors to do a good job of pre-embedding and reserving work; 3. Cooperate with process equipment, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top