Inverter terminal blocks belong to a kind of connector, the variety is divided into single hole, double hole, socket, hook, etc., from the data point, copper silver plating, copper galvanized, copper, aluminum, iron, etc. Their effect is mainly to transmit electrical signals or conductive use, in the project, it is the interface reserved for the station project in front of the station project, and it is the embedded facility for the interface project behind the station.
The inverter is divided into two categories: strong terminal and weak terminal;
(1) Strong current terminal refers to high-voltage and high-power terminals, generally including RST power supply terminals, UVW motor terminals, P+ and N-DC bus terminals, PB braking resistor terminals, E heat dissipation aluminum sheet grounding terminals, etc. The energy of the inverter is transferred through these terminals, processed and then transferred to the motor.
(2) Weak current terminals include +24V, com, +10V, GND weak power terminals, FWD forward rotation, REV reversal, X1-X7 multi-function terminals, RA, RB, RC internal relay output terminals, AO analog output terminals, VI, AI analog output terminals, RS485 communication terminals, etc., which are also called control terminals.
How the inverter rotates, how much speed it rotates, what is its current state, and how it works together with peripheral equipment are all completed by the level bumps of these terminals. Generally, FWD, REV, X1-X7 pass through the opening and closing of the contact signal of the external contactor, and send the command to the inverter. Generally, normally open contacts are used to control more, and some inverters can also demarcate the forward and negative logic of the logic signal by themselves.
|
More on that
|
Schneider servo model introduction
LXM23DU01M3X servo drive 0.1 kW
LXM23DU02M3X servo drive 0.2 kW
LXM23DU04M3X Servo drive 0.4 kW
LXM23DU07M3X Servo drive 0.75 kW
LXM23DU10M3X ...
|
|
The difference between circuit breaker and air opening - Schneider
An air switch, also known as an air circuit breaker, is a type of circuit breaker. It is a switch that only needs the current in the circuit to exceed the rated current will be actively disconnected, and is generally used to avoid circuit overload and short-circuit maintenance (some also have low voltage maintenance functions) can not maintain electric shock, to put it bluntly, it is ...
|
|
Frequency converter and PLC connection problems - Schneider
When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1.PLC switch ...
|
|
Anti-electromagnetic interference method - Schneider
There are three main sources of electromagnetic disturbance to the industrial system: first, space field disturbance, which enters the system through electromagnetic wave radiation; the second is power disturbance, which directly damages the system; The third is the signal disturbance channel, which enters the system through the front and rear channels connected to the host. In order to ensure that the instrumentation ...
|
|
Schneider UPS power supply installation steps
UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...
|
|
Technical causes of Schneider low-voltage circuit breaker accidents
(1) Operational failure
Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the fundamental and important function of the high-voltage circuit breaker is to act correctly and quickly remove the fault of the power grid. If the circuit breaker is dragged or misoperated, it will pose a serious threat to the power grid, first of all: (1) expansion ...
|
|
Schneider Thermal Relay Model Meaning
The function of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and twisted to advance the action organization to drive the contact action, so as to disconnect the motor control circuit to realize the motor power-off thermal relay ...
|
|
Schneider instrumentation winter insulation measures
The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on.
Selection method
Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...
|
|
Inverter trip protection circuit – Schneider
After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time.
Inverter hopping ...
|
|
The operation essentials of Schneider disconnectors
Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it is able to disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. Secondly, the Schneider barrier switch can be used with the circuit breaker to change the operation of the system.
|
|
Servo motor selection process – Schneider
1. Load organization (acknowledging the type of tissue and its specific data, such as ball screw length, ball screw diameter, stroke, pulley diameter, etc.)
2. Form of action (acknowledging the form of action of manipulating the target, the relationship between time and speed; Will manipulate ...
|
|
Schneider ATV312 inverter failure
1. OLF is motor overload.
Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong.
Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...
|
|
Advantages and disadvantages of closed busbars compared with open busbars - Schneider
The advantages of closed busbars over open busbars are:
1) Closing the bus duct can reduce the grounding fault, avoid the short circuit between phases, basically eliminate the grounding defect caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate ...
|
|
Schneider ATV71 selection and letter meaning
The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load).
Here are two examples:
Example 1:
Schneider Inverter Type: ATV71HD11N ...
|
|
Frequency converters and their control – Schneider
AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...
|
|
Schneider low-voltage circuit breaker selection method
1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the short-circuit current breaking ability of Schneider frame circuit breaker is larger and larger than that of device type. Usually, the branch line chooses ...
|
|
The selection method of inverter power - Schneider
The system power is equal to the product of the inverter power and the motor power, as long as both are operating at a higher power, the system power is higher. From the power point of view, when selecting the power of the inverter, the following points should be noted:
...
|
|
Schneider Electric has announced a partnership with RMSI
Schneider Electric has named RMSI North America, an IT services company that provides geospatial and software solutions, as an ArcFM Specialty Partner. RMSI is well positioned to provide GIS solutions for utilities and telecommunications companies across the entire geospatial value chain...
|
|
Design and calculation method of inverter braking resistance - Schneider
1. The number of braking resistor boxes is roughly calculated as: motor power (KW)/11.2 (take the upper limit of the integer).
2. The selection of the power of the braking unit is generally (1-2) times the power of the inverter;
3. The function of braking resistor ...
|
|
Solutions to Schneider drive fault codes
PHF: 1. The power supply of the inverter is not right or the fuse is blown; 2. There is a transient problem in a certain phase. 1. Check the power connection and fuse; 2. Reset.
USF: 1. Power supply voltage undervoltage; 2. Instantaneous voltage drop; 3. The load resistor is damaged. 1 Check the power supply voltage; 2 Substitutions ...
|
|