There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. The false load is to use a resistor of several hundred ohms (a light bulb can also be used), string it on the main circuit, if there is a fast melt, remove it, and install the resistor; If there is no fast melting, it can be disconnected anywhere on the main return, and the resistor can be strung on it! This resistor has a current limiting effect, and when the module has a short circuit, the module will not be burned off, and the output of the measurement inverter is normal after starting, and then the false load will be removed!
However, there are also several problems to be paid attention to in the connection of false loads:
1. It should be connected between the capacitor and the module, not between the rectifier and the capacitor, because the capacitor discharge is enough to burn out the module.
2. When the switching power supply is fast-melting, you can't put the false load on the fast-melting, otherwise the bulb will be on after the power is sent, and the switching power supply sometimes does not work!
3. The false load should also be connected behind the DC voltage detection point, so that when the inverter output is not normal, the inverter will not jump "low voltage", so that you can see which output is faulty!
The inverter has a common feature, that is, if the switching power supply of the inverter is not directly supplied from the filter capacitor of the main circuit, but from the input end to the main circuit separately and independently supplied, if the power supply is 380V, then the best transformer into 220V (rectification) and then supply the switching power supply, although the inverter will be complicated, but its fault rate will be greatly reduced! Because a large part of the inverter is related to the switching power supply! When the inverter is running, the DC voltage of the main circuit is unstable many times, if the switching power supply is supplied from the filter capacitor of the main circuit, the switching power supply is easy to break! Schneider Electric Smart Building Days.
|
More on that
|
The difference between the highest frequency and the basic frequency of the inverter - Schneider
1. There are two ways to say the fundamental frequency:
(1) The frequency corresponding to the maximum output voltage of the inverter is called the fundamental frequency;
(2) When the output voltage of the inverter is equal to the additional voltage, the minimum output frequency is called the fundamental frequency. The fundamental frequency is expressed in fBA.
...
|
|
Deterioration site and the principle of higher harmonic generation - Schneider
1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.
|
|
Schneider ATV610 inverter applications
The Schneider ATV610 inverter is suitable for specification loads and can be used in a wide range of industries and infrastructure. Including: petrochemical, power plant, industrial and civil buildings, water treatment and sewage treatment, HVAC, thermal heating, constant pressure water supply, and other applicable occasions. In these jobs ...
|
|
The inverter controls the speed of the AC motor – Schneider
Most of the motors used in the industry are of this type. The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the working principle of the motor. Since the pole ...
|
|
Schneider PLC signal light meaning
Take the Schneider PLC with model number TWDLCAA40DRF as an example:
The first PWR: is the meaning of power supply;
The second RUN: is the PLC operation indicator; Long dark: The application is not fulfilling; Shine: The controller is in a stay or a mistake in performance; Solid on: The controller is in operation ...
|
|
Schneider lamellar relays
Schneider RSL Thin Sheet Relay, as a member of the large family of ZelioRelay series relays, RSL Thin Plate Relays will be committed to saving users space and time in the device, and improving the stability of the system.
Schneider Electric Vice President of China, Head of Industrial Division, Xiu De...
|
|
The protection function of the inverter - Schneider
Protective functions can be divided into the following two categories:
(1) After detecting the abnormal situation, the correction action is automatically carried out, such as overcurrent loss speed avoidance, regeneration overvoltage stall avoidance.
(2) After detecting the abnormality, the PWM control signal of the power semiconductor equipment is closed, so that the motor automatically stops. As...
|
|
Inverter maintenance mantra method - Schneider
Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge;
It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test;
Input and output PN junction, three-phase balance and then unshelling;
Look at the nameplate before powering on, the wrong voltage will blow up;
The bus has no electricity to see that it is safe, and the rectifier filter is wrong ...
|
|
The inverter has a problem supplying power to the motor – Schneider
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
The inverter is a supporting operation with the inverter motor.
|
|
Schneider Instrumentation Classification
1. Industrial automation appearance and control system. This is generally referred to as PA, FA in foreign countries. PA is called process automation, and FA is called factory automation. The appearance and control system used in process automation and factory automation belong to this category, and some parts of the appearance of analytical instruments and electrical instruments also belong to the ...
|
|
The difference between Schneider verification, calibration, and calibration
What is the difference and contact between the instrument, external work verification, calibration, and calibration?
Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are:
The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...
|
|
Schneider Compact NSX series molded case circuit breaker selection recommendation
The molded case circuit breaker is an important part of the maintenance of the low-voltage distribution system and the motor, and maintains the safety of the distribution system and electrical equipment. As an important application scenario of molded case circuit breakers, these key occupations of new infrastructure such as new energy and telecommunications have extremely important equipment performance, stability and adaptability.
|
|
How Schneider contactors work
How it works
Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect with the equipment of the high-current control circuit, it has been used in electrical engineering.
|
|
The UPS boot panel does not show that the UPS is not working - Schneider
Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work
Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop:
1. Check ...
|
|
Line leakage detection method - Schneider
Line leakage detection method, leakage check method summary, if a closing, leakage switch will trip, this kind of front leakage, check the method is as follows:
1. Disconnect all the separation gates, close the main gate, close the separation gates one by one, and close them to ...
|
|
Schneider molded case circuit breakers NSX, CVS, EZD differences
1. NSX series is Schneider's high-end molded case circuit breaker, with the best performance in all aspects, and of course, the price is also the most expensive.
2. CVS series, which is the main series of Schneider, has the second best performance compared with the NSX series, but can meet the vast majority of applications, and the price is more affordable.
3 ...
|
|
Schneider Electric has announced a partnership with RMSI
Schneider Electric has named RMSI North America, an IT services company that provides geospatial and software solutions, as an ArcFM Specialty Partner. RMSI is well positioned to provide GIS solutions for utilities and telecommunications companies across the entire geospatial value chain...
|
|
Schneider inverter external potentiometer connection
The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
Servo motor selection process – Schneider
1. Load organization (acknowledging the type of tissue and its specific data, such as ball screw length, ball screw diameter, stroke, pulley diameter, etc.)
2. Form of action (acknowledging the form of action of manipulating the target, the relationship between time and speed; Will manipulate ...
|
|
Analysis of common problems of Schneider inverter
1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA?
Because the maximum output frequency parameter of the inverter is "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...
|
|