Schneider ATV71 selection and letter meaning
The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load).
Here are two examples:
Example 1:
Schneider Inverter Type: ATV71HD11N ...
|
|
Schneider instrumentation fault diagnosis method
1. Percussion hand pressure method
When we use the instrument, we often encounter the phenomenon that the instrument is running well and badly, and most of this phenomenon is caused by poor contact or virtual welding. In this case, percussion and hand pressure can be used.
The so-called "percussion" is the response to the ...
|
|
Schneider TRSS telemetry system solution
Schneider Electric provides safe, reliable, end-to-end telemetry solutions to help you meet the challenges of long-distance operations. With an outstanding reputation in the fields of appearance, manipulation and data collection, wireless communications, IT, and other industries and common sense, Schneider Electric telemetry system solutions can help ...
|
|
How to choose a Schneider circuit breaker?
First, calculate the value of the current of each branch
(1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...
|
|
Analysis of the causes of frequent overcurrent alarms of inverters - Schneider
(1) Caused by incorrect parameter setting.
If the acceleration time of the inverter is set too short, the change of the output frequency of the inverter far exceeds the change of the motor frequency, and when the inverter is started, it will trip due to overcurrent. Adjusting the acceleration time accordingly to different load conditions can eliminate this problem.
|
|
Schneider circuit board maintenance work commonly used instrumentation
Before preparing to do circuit board repair work, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience has shown that prepare some necessary circuit board repair things and appearance, to be able to reach ...
|
|
The protection function of the inverter - Schneider
Protective functions can be divided into the following two categories:
(1) After detecting the abnormal situation, the correction action is automatically carried out, such as overcurrent loss speed avoidance, regeneration overvoltage stall avoidance.
(2) After detecting the abnormality, the PWM control signal of the power semiconductor equipment is closed, so that the motor automatically stops. As...
|
|
The reason for the inverter trip - Schneider
Whenever the inverter is down due to a problem, a problem code will appear. The most common causes are overcurrent, overvoltage, inverter temperature, etc. It's a good idea to find an explanatory book with specific questions to be asked about.
1. Overload jump ...
|
|
Features of Schneider elliptical gear flowmeter
Elliptical gear flowmeter (also known as displacement flowmeter, gear flowmeter), classified as a positive displacement flowmeter, is a class with high accuracy in the flow surface. It uses a mechanical measuring element to continuously cut the fluid into a single known volume part, and according to the measuring chamber, it is repeated and repeated.
|
|
Schneider thermal relay selection method
1. In principle, the ampere-second characteristics of the Schneider thermal relay should be as close as possible to or even coincide with the overload characteristics of the motor, or under the overload characteristics of the motor, and at the same time, the Schneider thermal relay should not be affected (not acting) at the moment of short-term overload and start of the motor.
...
|
|
Introduction to the transformer connection group - Schneider
In the transformer planning process, the choice of wiring method is often not paid attention to. The three-phase transformer has A/B/C three-phase winding on the 1/2 side. The connection between them has a great impact on the operation performance of transformers, especially distribution transformers, and directly affects the quality of power supply. Therefore, the wiring ...
|
|
The difference between Schneider verification and calibration
(1) The intent is different
The intent of the verification is to carry out a mandatory comprehensive appraisal of the measuring equipment. This comprehensive identification of areas attributed to the value of the same value is a top-down process of value transfer. The verification shall identify whether the measuring equipment meets the specified requirements.
This kind of regulation requires ...
|
|
Schneider's small PLC part model
Schneider has M100/M200 for small programmable controllers, and M340 and M580 for medium and large programmable controllers
The compact M100 model is available in TM100C24RN, TM100C32RN, and TM100C40RN.
Small M200 ...
|
|
Schneider miniature circuit breaker code calling
Schneider miniature circuit breaker code marking method
For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is:
1--------- identification number
C65 ------ serial code
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
Introduction to Schneider PLC series
1. LMC058 & LMC078 Modicon Motion Controller Product Information
Faster machine planning
The motion controller uses the same programming software as the PLC;
Custom-made utility blocks for complex use;
Dedicated motion function library for programming, debugging, and diagnosis ...
|
|
Whether an AC circuit breaker can be used in a DC circuit
Schneider circuit breakers are used to open and break communication loops. The arc extinguishing of the communication system is simple, but the arc extinguishing of the DC system is more difficult. Because the system is different and the arc extinguishing principle is different, there is a big difference in structure and performance between the communication circuit breaker and the DC circuit breaker. Compared with the communication circuit breaker, the DC circuit breaker ...
|
|
Schneider touch screen touch deviation causes
(1) Problem--: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye center when calibrating the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: Some districts ...
|
|
Schneider inverter disturbance and treatment method
A. Methods of Communication:
(1) Radiation disturbance
(2) Conduction disturbance
B. Immunity Methods
With regard to nuisance signals transmitted by radiation methods, they are primarily weakened by wiring and shielding the radioactive source and the disturbed lines.
About Tong ...
|
|
Dual-fan inverter selection - Schneider
1. Qualified after inspection
When selecting a double fan inverter, it must be strictly checked for its quality. The first requirement is that it must have relevant certificates of qualified inspection, and some qualified materials must be taken out. This is the only way to ensure that this change ...
|
|
Inverter terminal block classification - Schneider
Inverter terminal blocks belong to a kind of connector, the variety is divided into single hole, double hole, socket, hook, etc., from the data point, copper silver plating, copper galvanized, copper, aluminum, iron, etc. Their effect is mainly to transmit electrical signals or conductive use, in the project, it is the station front engineering for the station after the project reserved for the connection ...
|