1. Why is the inverter used for fan and pump loads to save energy?
According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. That is, the torque is proportional to the square of the speed, and the power is proportional to the cube of the speed. Usually, the load of the fan pump is mostly selected according to the amount of full load operation, and most of the time in practice is not in the full load situation, so as long as the uniform speed drops slightly, the load power will drop very quickly, and then reach the energy saving effect.
However, when the motor direct starting method is selected, because the speed can not be scheduled, the wind shield and valve are often used to schedule the air volume or flow, which not only forms the waste of power but also forms the power grid impact and the flutter and water hammer of the equipment because of the excessive starting current.
When the inverter is selected to regulate the speed, the speed can be easily controlled according to the practical technical requirements. For example, when the motor speed is 80% of the rated speed, the load power is the cubic of the rated power (80%), that is, 50% is dominant. It can be seen that the speed is reduced by 20%, and the energy saving is more than 40%. Together, closed-loop constant voltage control can be easily completed, and the energy saving efficiency will be further advanced. The use of inverter avoids the impact on the power grid when starting, reduces the equipment failure rate, eliminates the flutter and water hammer phenomenon, extends the service life of the equipment, and also reduces the capacity request and reactive power loss of the power grid.
2. What is the basic equipment of the standard product of ATV71/61 inverter powered by three-phase 380V power supply?
Chinese LCD screen: 15KW below is optional, 15KW or more is standard.
DC incoming line reactor:
0.75kw-15kw without built-in DC reactor, optional as an accessory when needed;
The standard product DC reactor of more than 90KW is delivered with the inverter, and the user needs to follow the equipment diagram and equipment, assuming that the DC reactor is not ordered, and add a "D" at the end of the type;
18.5KW-75KW has been built-in. EMC input filters: All have built-in EMC.
3. How to complete the control of ATV38 and ATV58 through the operation panel?
First, in the control menu, set "LCC" to "YES" (panel operation);
Enter the "LFR" parameter in the adjustment menu, press the up and down keys to adjust the given value, and complete the control of the inverter.
4. How to communicate between multiple ATV71/61 inverters connected to the same bus and a graphic flash terminal?
The [Communication] menu → [Network MODBUS] → [MODBUS Address] (ADD) to set the address of each inverter.
When multiple drives are connected to the same flash terminal, the terminal actively flashes the drive address.
In the multipoint format it is possible to visit all menus, but does not allow the terminal to be controlled by a graphic flash. |
More on that
|
U-tube manometer error analysis – Schneider
(1) Temperature error. This refers to the change of the length of the scale and the density of the working fluid due to the change of ambient temperature, and the former can be ignored in general, and the latter should be appropriately corrected. For example, when water is changed from 10°C to 20°C, its density changes from 999. 8kg/m^3 reduced to 999.8kg/m^3 ...
|
|
Schneider's new Modicon programmable controller PLC series
Schneider Electric, the global energy efficiency management specialist, has launched the new Modicon Programmable Manipulator (PLC) M221 series, M241 series and M251 series under the MachineStruxure machine automation channel. This series of new products is tailored for industrial OEM shopping malls, relying on Schneider Electric global ...
|
|
Frequency converters and their control – Schneider
AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...
|
|
Technical causes of Schneider low-voltage circuit breaker accidents
(1) Operational failure
Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the fundamental and important function of the high-voltage circuit breaker is to act correctly and quickly remove the fault of the power grid. If the circuit breaker is dragged or misoperated, it will pose a serious threat to the power grid, first of all: (1) expansion ...
|
|
Schneider switch socket authenticity
1. In terms of logo, the logo of the product is a sign of identity, so the genuine products will be very exquisite. The imitation is not very well handled on the logo, the plane contrast above the letter "A" is narrow, and even the top is directly pointed. We must pay attention to this point.
2. From ...
|
|
Schneider's method of improving the power factor of UPS power supplies
One. The significance of the progressive power factor.
1. Make full use of the ability of power equipment.
Each power supply unit has additional capacity, i.e. depending on the power. The total power output of the power supply equipment S, - part of the active power, the other part is the reactive power, the smaller the ...
|
|
Schneider servo motor advantages
Schneider servo motor is one of the brands of servo motor, the performance is relatively good, is a brand made in Germany, in China ** degree is relatively high. Servo motor refers to the servo system, (servomechanism) in which the mechanical components are controlled.
|
|
Precautions for the use and maintenance of instruments and meters - Schneider
Attention should be paid to the following matters during the use and maintenance of the appearance of the instrument:
1. Don't blindly knock and bump when overhauling, so as not to expand the problem, and the more you repair, the worse it will become.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the power-on ...
|
|
Schneider turbine flowmeter selection considerations
1. According to the requirements of measurement intention:
It is required to select the unit with instantaneous flow rate or cumulative flow rate (cumulative flow), the unit of flow display, measurement accuracy, repeatability, linearity, flow scale and scale, measurement temperature, pressure loss, temperature and pressure compensation, output signal characteristics and echoes.
|
|
Schneider automatic control instrument construction content and procedures
1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed design documents), construction organization design, equipment list, data budget, and list of machined parts;
2. Cooperate with civil engineering majors to do a good job of pre-embedding and reserving work;
3. Cooperate with process equipment, ...
|
|
Schneider AC inverter usage category
Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including squirrel cage or slip ring motor, resistor, when the switch or break is generated in the motor abort, start or run...
|
|
"Five Ways" to Solve Life Sciences Industry Challenges – Schneider
In life sciences careers, equipment performance is critical to ensuring business continuity and useful production time. The main challenges faced by the industry include: maintaining the positive impact of environmental parameters on product quality, managing multiple systems in a "siloed" state, and using existing infrastructure sensitively and efficiently.
|
|
Schneider XPS safety control module selection method
(1) Evaluate the safety control level that the machinery and equipment need to reach
(2) Confirm the type of input signal to be monitored
and (3) the number of input signals that need to be monitored
(4) The number and type of channels that the module needs to output
(5) Whether it is necessary to control the output device (such as ...
|
|
Common analysis method for electrical control line faults - Schneider
1) Survey and research method. The investigation and research method is to understand the obvious problem phenomena through "seeing", "listening", "smelling", "touching" and "asking"; After visiting the operator, understand the cause of the failure; A common way to help find the fault point after asking others or consulting information ...
|
|
Circuit breaker failure protection - Schneider
Circuit breaker failure maintenance refers to the relay maintenance action of faulty electrical equipment when the trip command is announced and the circuit breaker refuses, the maintenance action information of the faulty equipment and the current information of the rejected circuit breaker constitute the judgment of circuit breaker failure, and other related problems in the same plant and station are cut off in a shorter time limit.
|
|
Schneider diode selection experience and substitution method
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...
|
|
Schneider inverter ATV310 instruction with given
The instructions of the inverter are given with the given
conf→400-
→ 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...
|
|
Causes of Schneider UPS power supply damage
1. Air conditioning: It is generally forbidden to use UPS power supply, because the air conditioning is very large and belongs to the rational load.
Not suitable for belt loads
2. Motor: It is necessary to choose a large-capacity UPS power supply, because it is a rational load, and it is ...
|
|
Schneider intermediate relays
Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models.
...
|
|
The role of Schneider thermal relays
The effect of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and bent to advance the action mechanism to drive the contact action, so as to disconnect the motor control circuit to complete the motor power-off thermal relay ...
|
|