Schneider inverter enters the parameter setting method

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct

2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification

3. Next, set the functional parameters to start the motor, and pay attention to debugging the control parameters to meet the control requirements

4. If pressing the "Local/Remote" button does not work, then the HMI command parameters need to be corrected to complete the operation.

                            Schneider inverter enters the parameter setting method

More on that
How to choose the Schneider ATV71 and the meaning of the letter How to choose the Schneider ATV71 and the meaning of the letter

The Schneider inverter model generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy load is still light load type). Here are 2 examples: Example 1: Schneider inverter model: ATV71HD11 ...

Schneider Category VI unshielded RJ45 information module Schneider Category VI unshielded RJ45 information module

Product Introduction compose 1. RJ45 module body, 8 IDC contact pins 2. Crimping module 3. Back cover 7751S (optional) Operating temperature range -40°C to +70°C (65°C for non-stop use) ...

Schneider AC inverter usage category Schneider AC inverter usage category

Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including squirrel cage or slip ring motor, resistor, when the switch or break is generated in the motor abort, start or run...

There is a remote code execution vulnerability in Schneider industrial equipment There is a remote code execution vulnerability in Schneider industrial equipment

Recently, Armis security researchers have reported that Schneider Electric's programmable logic manipulators (PLCs) have serious and unpatched gaps in long-distance code fulfillment, allowing intruders to manipulate their various industrial systems. Schneider ...

Schneider UPS uninterruptible power supply debugging precautions Schneider UPS uninterruptible power supply debugging precautions

1. Check whether all switches are in the disconnected position; 2. Check whether there are foreign objects in the UPS uninterruptible power supply cabinet and transformer; Check whether the flat cable connection is correct and whether it is loose; 3. Check that the connected plug is ...

Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award

Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.

Measures to reduce the interference of Schneider inverters themselves Measures to reduce the interference of Schneider inverters themselves

(1) Add inductance and capacitance on the input side of Schneider inverter to form an LC filtering network (2) The power cord of the Schneider inverter is supplied directly from the transformer side. (3) If conditions permit, a separate ...

Causes of Schneider UPS power supply damage Causes of Schneider UPS power supply damage

1. Air conditioning: It is generally forbidden to use UPS power supply, because the air conditioning is very large and belongs to the rational load. Not suitable for belt loads 2. Motor: It is necessary to choose a large-capacity UPS power supply, because it is a rational load, and it is ...

Factors influencing the differential thermal analysis of instrumentation - Schneider Factors influencing the differential thermal analysis of instrumentation - Schneider

The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different measurements are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...

Schneider circuit board maintenance work commonly used instrumentation Schneider circuit board maintenance work commonly used instrumentation

Before preparing to do circuit board repair work, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience has shown that prepare some necessary circuit board repair things and appearance, to be able to reach ...

Precautions for setting parameters of Schneider inverter Precautions for setting parameters of Schneider inverter

 Debugging parameters: ​ 1. Acceleration and deceleration time Speed up the time setting requirements: the acceleration current is constrained below the overcurrent capacity of the inverter, so that the overflow will not cause the inverter to trip; Deceleration time setting key ...

Introduction to the transformer connection group - Schneider Introduction to the transformer connection group - Schneider

In the transformer planning process, the choice of wiring method is often not paid attention to. The three-phase transformer has A/B/C three-phase winding on the 1/2 side. The connection between them has a great impact on the operation performance of transformers, especially distribution transformers, and directly affects the quality of power supply. Therefore, the wiring ...

About the characteristics of Schneider explosion-proof inverter cabinet About the characteristics of Schneider explosion-proof inverter cabinet

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It mainly regulates ordinary three-phase by changing its output frequency ...

Schneider AC contactor precautions Schneider AC contactor precautions

There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A When installing, it should be in accordance with the regulations...

Schneider Vijeo-Designer compilation error factor Schneider Vijeo-Designer compilation error factor

Q1833: Because you are using an older version of Runtime, the download does not last. Please use the Runtime Device program on the Vijeo Designer CD to upgrade the runtime. When you download to an older runtime ...

Schneider lamellar relays Schneider lamellar relays

Schneider RSL Thin Sheet Relay, as a member of the large family of ZelioRelay series relays, RSL Thin Plate Relays will be committed to saving users space and time in the device, and improving the stability of the system. Schneider Electric Vice President of China, Head of Industrial Division, Xiu De...

Analysis of the causes of Schneider touch screen touch deviation Analysis of the causes of Schneider touch screen touch deviation

(1) Fault--: Contact error Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing. Phenomenon 2: Some districts ...

Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker

Circuit breaker action time test. The closing and opening control lines of the circuit breaker mechanical characteristics tester are respectively connected to the secondary control line of the circuit breaker, and the lead wires of each break of the circuit breaker are connected to the mechanical characteristics of the circuit breaker with the test wiring.

Schneider considers the safety of lithium batteries from four perspectives Schneider considers the safety of lithium batteries from four perspectives

In China, the trend of UPS switching to lithium batteries will become more and more rapid. As a global leader in data center infrastructure solutions and services, Schneider Electric found that in addition to the purchase price factor, Chinese customers are now choosing the weight of UPS lithium batteries after accurate positioning and inquiry of shopping malls.

A brief description of the working principle of Schneider power soft starter A brief description of the working principle of Schneider power soft starter

Schneider ATS48 soft starter is composed of three opposite parallel thyristors, which are connected in series between the three-phase power supply and the motor, by changing the trigger angle of the thyristor gate pulse, the conduction angle of the thyristor gradually increases from zero, according to the pre-set soft starter parameter curve, the motor output torque ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top