1. Overload maintenance failure: The circuit breaker should be tripped for maintenance when the current exceeds the rated current, but sometimes the overload maintenance failure may be due to some reasons. This may be due to incorrect overload maintenance settings, long overload periods, thermal aging due to successive overloads, etc.
2. Short-circuit maintenance failure: The circuit breaker should be tripped and maintained quickly when it is subjected to short-circuit current, but sometimes the short-circuit maintenance fails for some reasons. This may be due to improper maintenance sensitivity settings and advanced short-circuit currents.
3. Excessive leakage current: the circuit breaker will have a leakage maintenance function during operation, and it should be tripped for maintenance when the leakage current exceeds the rated value, but sometimes the problem of excessive leakage current may occur due to some reasons. This may be due to unstable power supply, poor ground contact, equipment problems, etc.
|
More on that
|
AC-DC inverter composition and function - Schneider
The AC-DC inverter main circuit consists of three components: the rectifier main circuit, the center circuit and the inverter circuit.
1. The main circuit is the power replacement part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the voltage source ...
|
|
The role of Schneider thermal relays
The effect of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and bent to advance the action mechanism to drive the contact action, so as to disconnect the motor control circuit to complete the motor power-off thermal relay ...
|
|
Inverter terminal block classification - Schneider
Inverter terminal blocks belong to a kind of connector, the variety is divided into single hole, double hole, socket, hook, etc., from the data point, copper silver plating, copper galvanized, copper, aluminum, iron, etc. Their effect is mainly to transmit electrical signals or conductive use, in the project, it is the station front engineering for the station after the project reserved for the connection ...
|
|
There is no indication on the UPS boot panel that UPS is not working - Schneider
Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop:
1. Check whether the mains input wire is incinerated;
2. If the mains input is stable...
|
|
NSX molded case circuit breaker selection - Schneider
The Schneider NSX molded case circuit breaker has a double rotary contact construction for maintenance, and the high-end electronic trip unit allows for accurate measurement and easy communication. Schneider NSX molded case circuit breaker conforms to IEC60947-2, GB14048.2, China's CCC certification and multinational classification certification...
|
|
Heat dissipation strategy for frequency converters – Schneider
Drives power and operate commercial and industrial motors, and thermal protection is necessary in accordance with their planning and operating environment. The main advantages of the frequency converters are flexible handling, smooth start-up and shutdown functions, and significant energy savings due to centrifugal fans and pumps operating under variable loads. ...
|
|
The difference between Schneider verification, calibration, and calibration
What is the difference and contact between the instrument, external work verification, calibration, and calibration?
Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are:
The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...
|
|
Schneider Category VI unshielded RJ45 information module
Product Introduction
compose
1. RJ45 module body, 8 IDC contact pins
2. Crimping module
3. Back cover 7751S (optional)
Operating temperature range
-40°C to +70°C (65°C for non-stop use)
...
|
|
Schneider Intermediate Relay Model Letter Meaning
RXM: Schneider's miniature center relay
The first 2: indicates the number of contacts, and the normally open contact is 2
LB: Indicates that the product has LED light
The second 2: indicates the number of contacts, and the normally closed contacts are 2
BD: Indicates that the supply voltage used is DC 24V
...
|
|
The difference between an inverter and a servo drive – Schneider
In terms of frequency converters:
The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...
|
|
Key points of maintenance of Schneider battery
(1) Insulating pads should be arranged in the maintenance channel of the battery pack.
(2) It is strictly forbidden to use batteries of different manufacturers, different capacities and different models in the same system.
(3) VRLA batteries do not need to be charged for the first time before use, but should be recharged. Replenish the charge ...
|
|
Schneider intermediate relays
Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models.
...
|
|
Schneider selection of different types of circuit breakers
Miniature circuit breakers are: A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc.
Molded case circuit breakers are: NSX, NSE, EZD, NSC, large molded case NS.
Structural circuit breakers include: MT, MTE, etc.
...
|
|
Schneider DC air open up plus or minus? How to connect the incoming and outgoing lines?
The air switch is divided into the upper inlet line and the lower inlet line of the power supply, 1 is - 3 is + 2 is + 4 is - when the upper line is inlet, 2 is + 4 is - This is related to the internal trip curve.
DC circuit breaker is used for DC system operation method conversion or fault removal ...
|
|
Features of Schneider's different PLC series
Schneider PLC series mainly includes:
Schneider NEZA PLC (Schneider TSX08 series);
Schneider Quantum PLC (Schneider 140 series);
Schneider Micro PLC (Schneider TSX37 series);
Schneider Premium PLC (Schneider TSX...
|
|
"Five Ways" to Solve Life Sciences Industry Challenges – Schneider
In life sciences careers, equipment performance is critical to ensuring business continuity and useful production time. The main challenges faced by the industry include: maintaining the positive impact of environmental parameters on product quality, managing multiple systems in a "siloed" state, and using existing infrastructure sensitively and efficiently.
|
|
Schneider appeared at the 5th China Power Distribution Technology Summit Forum
Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...
|
|
Schneider touch screen touch deviation causes
(1) Problem 1: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye when checking the alignment. Deal 1: Correct the position from the beginning.
Phenomenon 2: ...
|
|
Schneider inverter series at a glance
1. ATV11 series
The Schneider ATV11 series is primarily used in three-phase asynchronous motor inverters with a power range of 0.18 to 2.2 kW.
2. ATV12 series
ATV12 Schneider inverter for power scale 0.18k...
|
|
Inverter power-saving method - Schneider
First, it is a fan/pump load
Second, the device itself has a power-saving function (software support)
Third, we need to work for a long time
The above are the three conditions that reflect the results of power saving. If it is said that the power frequency of the inverter is energy-saving without conditions, it is ...
|
|