1. Measurement of action interval; When the action piece approaches the sensing surface of the switch from the front, the interval between the action of the switch is the interval between the action of the switch, and the measured data should be within the parameters of the product.
2. Determination of the release interval; When the action piece is separated from the sensing surface of the adjacent switch from the front, and the switch is turned from action to release, the interval between the action piece and the sensing surface is determined.
3. Determination of the return difference H; The value of the difference between the action interval and the release interval.
4. Action frequency measurement; Drive the bakelite disc with a speed-regulating motor, fix a number of steel sheets on the disc, adjust the interval between the switch sensing surface and the action piece, about 80% of the switch action interval, rotate the disc, make the action piece close to the switch in turn, install a speed measuring device on the disc spindle, and the switch output signal is shaped and connected to the digital frequency meter. At this time, the motor is started, and the speed is gradually increased, and the action frequency of the switch can be directly read out by the frequency meter under the condition that the product of the speed and the action piece is equal to the frequency count.
5. Repeatability determination; The action piece is fixed on the measuring tool, and the movement speed of the action area approaching the switch from the front of the switch sensing surface is controlled at 0, 1mm/s by 120% of the switch action interval. When the switch is in action, the reading on the gage is read out, and then the action zone is exited to disconnect the switch. Repeat this 10 times, and then calculate the difference between the value of the 10 measured values and the small value and the average value of 10 times, and the large difference is the repeatability error.
|
More on that
|
Autonex launches a new product - multi-channel pressure sensor PSM series
The multi-channel pressure indicators of the PSM series can display the measured values of up to 4 or 8 channels of analogue pressure sensors. When used in conjunction with our PSS series pressure sensors, the sensor type, pressure type and range can be automatically recognized without additional settings. Users can also easily ...
|
|
Pressure Sensor Everyday Protection – Ottonix
1. Check the standard of the equipment hole: Assuming that the standard of the equipment hole is not suitable, some of the threads of the sensor will be slightly worn during the equipment process. This not only affects the sealing performance of the equipment, but also makes the pressure sensor inadequate, and may even cause safety hazards. ...
|
|
Load cell quality selection – Autonex
1. Observe whether the outside of the load cell is deformed or cracked. If there is any damage, please contact the manufacturer immediately.
2. Find the connection end of the sensor in the weighing controller, and measure the connection circuit of the sensor. The general excitation voltage (between EXC+ and EXC-) is 5-10V, and the output ...
|
|
Principle and application field of Ottonix panel table
Panel meter, also known as the dial table or meter head, the full name is the panel device instrument (panel device instrument), English Panel Meter. Because this kind of instrument device is fixed on the surface of the equipment for viewing and operation, it is called a panel table, which is a functional part of the screen equipment.
...
|
|
The difference between switching power supply and module power supply – Autonix
Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog loads.
|
|
Autonics BH series photoelectric sensors
The BH series photoelectric sensors can be used with M18 fixing nuts and fixing nuts for frontal equipment, or with M3 bolts and nuts for peripheral equipment. Sensitive equipment options promise easy application in a variety of industrial environments. The sensor can be equipped with a simple wire to generate individual or simultaneous N...
|
|
Causes and solutions for overheating or burning of AC contactor coils
Reasons: 1. The polar surface of the communication core is uneven or the demagnetization air gap is too large;
2. The double coil of DC operation derived from the communication contactor is overheated due to the fact that the normally closed interlocking contact is not released by welding;
3. The frequency of operation is too high;
4. Poor coil manufacturing or due to mechanical damage, absolute ...
|
|
Precautions for the use of Autotonics safety light curtains
Cover the safety light curtain with your hands and observe whether the indicator light conversion is normal.
During the use of the punch photoelectric protection device, the orientation of the photoelectric protection device shall not be changed at will.
In the protection zone, the light curtain should be blocked by hand, and the machine should be able to stop the operation immediately.
...
|
|
Wiring of the load cell – Autonex
The load cell can be wired in two different ways with input and output:
One is the four-wire connection method
The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very fast to use, but when the cable is long, it is very easy to be affected by the working temperature.
|
|
Classification and working principle of proximity switches – Autonex
According to the different operating principles, it can be divided into inductive type, capacitive type, photoelectric type and magnetic inductance type. According to the type of circuit current, it can be divided into AC type and DC type. The inductive head of an inductive proximity switch is an inductive coil with a ferrite core, which can only detect metal bodies. Raise...
|
|
How to install an Autotonics voltage sensor
Voltage sensor refers to a sensor that can sense the measured voltage and convert it into a usable output signal, in a variety of detection and control systems, it is often necessary to track and collect the communication DC voltage signal that changes at high speed, and do spectrum analysis on some more complex voltage waveforms. Voltage Sensors ...
|
|
Pressure sensor identification items and verification methods
1. Look at it visually.
2. Verify the sealing and preloading of the system.
3. The pressure sensor is equipped on the pressure standard equipment, including the pressurization (or vacuuming) equipment, and the pressure standard equipment with liquid as the pressure transmission medium should sweep the air in the pipeline.
4 pressure sensors, ...
|
|
How to use the universal proximity switch safely – Autonex
Proximity switches, as the name suggests, are changes when approaching an object. This type of switch is generally used in mechanical motion, when two objects are approaching, the trigger switch gives a signal, and the control unit (PLC) detects this signal and adopts the next action.
...
|
|
Precautions for the use of photoelectric sensors
First, the selection of its primary consideration for the selection of three points: how wide the groove width should be; resolution (slit width); Fixation
1. The width of the slot, the detection object needs to pass through the slot of the slot-type optocoupler to block the infrared light, so the slot width of the photoelectric sensor should be wider than the detection object, and there should be a certain ...
|
|
Autotonics has added a blackout action mode sensor
Autonex has recently launched a new shading action form to add a space for users to choose. The BTF series of ultra-thin photoelectric sensors has a new dark ON form to increase the user's selection space. The selection of self-developed special IC, 3.7mm ultra-thin planning, suitable for small space ...
|
|
Sensor fault judgment and solution - Autonics
1. Air flow meter problem
Problem characteristics: The vehicle is shaking at idle, high fuel consumption, weak at high speed, and black smoke from the exhaust pipe.
View and dissect: through the fault diagnostic instrument detection, the engine air flow meter data block is seriously exceeded, the cause of the air flow meter damage, ...
|
|
Introduction to the resolution of the Autonoix encoder
Depending on the resolution supported by the encoder, encoders can be divided into marker encoders, HD encoders, and Full HD encoders. The higher the frame rate, the clearer the video.
1. What does the resolution of the encoder mean?
The resolution of the encoder refers to the encoder passing through a line or a dark line (also ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|
|
Load cell structure and function – Ottonix
Load cells are used to measure weight and can be found everywhere in our daily lives, such as at supermarket counters or on highways.
Load cells generally consist of elastomers with strain gauges. Elastomers are generally made of steel or aluminum. It is very robust and has very little elasticity. ...
|
|
Classification and advantages and disadvantages of infrared sensors – Autonex
Infrared sensors include an optical system, a detection element, and a conversion circuit. Optical systems can be divided into two categories: transmissive and reflective according to different structures. According to the working principle, the detection element can be divided into thermal detection element and photoelectric detection element. The most widely used thermistors are thermistors. Thermistor...
|
|