Cover the safety light curtain with your hands and observe whether the indicator light conversion is normal.
During the use of the punch photoelectric protection device, the orientation of the photoelectric protection device shall not be changed at will.
In the protection zone, the light curtain should be blocked by hand, and the machine should be able to stop the operation immediately.
When the slider is at the bottom dead center (180 degrees), the light curtain is blocked, and the machine tool slider should be able to return.
For presses that can only complete the top dead center protection, when the slider stops on the top dead center and the slider blocks the light curtain, the next operation cannot be started.
After replacing the mold, it is necessary to adjust the safety distance and safety orientation of the protection device by the special manager.
When disassembling and assembling the light curtain and transmission line, the power should be turned off first, and it is necessary to be operated by professionals to prevent the occurrence of danger.
Check that the transmitter and receiver of the safety light curtain are installed correctly with the respective cables, and that the cable terminals are accurately connected to the power supply and controller.
After about 1 second, if the yellow indicator light of the transmitter is stable, the indicator light of the receiver is all turned off, indicating that the light curtain sensor has entered the normal operating condition.
|
More on that
|
The difference between switching power supply and module power supply – Autonix
Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog loads.
|
|
Instrumentation Fault Diagnosis Method - Ottonix
1. Percussion hand pressure method
It is common to encounter the phenomenon of good and bad operation of the instrument, and most of this phenomenon is due to poor contact or virtual welding. In this case, percussion and hand pressure can be used.
The so-called "percussion" is to ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|
|
Advantages of Autonix photoelectric switches
Autonics continuously improves the product function and quality, so that the product is at the international first-class level. For more than 10 years, the market share of the products in Korea has been maintained.
1. Adopt self-developed special IC ...
|
|
High Temperature Pressure Sensor Accuracy Affects - Autonex
A high-temperature pressure sensor is a sensor that converts pressure into an electrical signal output, which usually consists of two parts, namely a sensitive element and a conversion element. The sensitive element refers to the part of the sensor that can directly feel or respond to the measurement; The conversion element refers to the sensitive element in the sensor ...
|
|
Load cell structure and function – Ottonix
Load cells are used to measure weight and can be found everywhere in our daily lives, such as at supermarket counters or on highways.
Load cells generally consist of elastomers with strain gauges. Elastomers are generally made of steel or aluminum. It is very robust and has very little elasticity. ...
|
|
Ultrasonic flow sensor principle
Ultrasonic flow sensor is a new type of general-purpose time-difference multi-function ultrasonic sensor suitable for industrial environments, mainly using low-voltage multi-pulse balanced emission acceptance technology, which can be mainly applied to measure the flow of most clean and uniform liquids without large concentrations of suspended particles or gases.
|
|
How to choose a pressure sensor fitting – Ottonix
At present, there are not many single ferrule terminal joints on the market, and most manufacturers are using double ferrule terminal joints, and the market price is about 9-18 yuan, and the price is different according to different types. Fittings, whether they are double ferrule end fittings or single ferrule end fittings, are all ...
|
|
Otonic photoswitch determination
1. Measurement of action distance; When the action piece is close to the sensing surface close to the switch from the front, the distance close to the switch action is the action distance close to the switch, and the measured data should be within the parameters of the product.
2. Release distance ...
|
|
Autotonix torque transducer selection
1. Selection of reliability
The potential of a sensor to persist in its properties over a period of time is called reliability. In addition to its own structure, the key factor affecting the long-term reliability of the controller is the use of harsh environments.
Harsh environments symmetrical heavy-duty sensors may lead to ...
|
|
Range of sensor applications – Autonex
The sensor is a very widely used detection device, which is used in environmental monitoring, traffic management, medical health, agriculture and animal husbandry, fire safety, manufacturing, aerospace, electronic products, and other fields. It can feel the information being measured, and can press the felt information ...
|
|
Pressure sensors in servo presses – Autonex
The pressure sensor in the servo press is built-in, which can ensure that the force on the spindle is not affected by the radial separation force, avoid part of the load in the installation, do not directly connect the workpiece, and is not easy to damage. High-speed rings of ...
|
|
Precautions for Temperature Sensor Installation and Use – Ottonix
1. Errors in improper introduction of devices
In other words, the thermocouple should not be installed too close to the door and the heating place, and the penetration depth should be at least 8-10 times the diameter of the maintenance tube; Maintenance of thermocouples ...
|
|
Installation steps for dynamic torque transducers – Autonex
Dynamic torque transducers can be used in the manufacture of viscometers, electric (pneumatic, hydraulic) torque wrenches, which have the advantages of high precision, fast frequency response, good reliability and long life.
Installation process:
1. According to the connection form of the shaft and the length of the dynamic torque sensor, determine the original ...
|
|
Autonicx was selected as one of the "Top 300 World-Class Enterprises" in Korea Industrial Control
With the strong support of our customers, Autoniks was selected as one of the "Top 300 World-Class" enterprises by the Korea government for the first time in the industrial control industry.
The Korea government's selection of "Top 300 World-Class Enterprises" is an increase in the number of choices ...
|
|
Strengths of Autonex photoelectric sensors
1. Long detection interval. By retaining an inspection interval of more than 10 m in the through-beam model, other inspection methods can be accomplished.
2. Less detection of objects. Because the detection of shading and reflection caused by the object is the detection principle, it is not like the proximity sensor to limit the detection of the object to the metal ...
|
|
Introduction to Autonix pressure sensor technology
1. Capacitive Capacitive pressure sensors are usually cleaned by a large number of OEM professional applications, testing the capacitance change between two surfaces, so that these sensors can sense the extreme pressure and vacuum level. In our typical sensor setup, the compact outer gram contains two metal exteriors, ...
|
|
Performance Indicators and Characteristics of Load Cells – Autotonicus
Performance indicators of load cell: 1. Dynamic characteristics, 2. Linearity, 3. Hysteresis characteristicsDynamic characteristics refer to the output characteristics of the sensor when the input changes. In practice, the dynamic characteristics of a sensor are generally used to indicate how well it responds to certain specification input signals. This is because the sensing ...
|
|
Gas Sensor Failure Analysis – Ottonix
A gas sensor is a converter that converts the volume fraction of a gas into an electrical signal. We will inevitably encounter some problems when using gas sensors, and we have analyzed them as follows:
1. How long does it take for the gas sensor to be used and then calibrated again: the initial calibration ...
|
|
Classification and advantages and disadvantages of infrared sensors – Autonex
Infrared sensors include an optical system, a detection element, and a conversion circuit. Optical systems can be divided into two categories: transmissive and reflective according to different structures. According to the working principle, the detection element can be divided into thermal detection element and photoelectric detection element. The most widely used thermistors are thermistors. Thermistor...
|
|