Ortonicx SFL/SFLA series safety light curtains
Leveraging the expertise accumulated in the development of industrial sensors, such as area sensors and mapping sensors, Ottonix has developed the SFL series (standard) and SFLA series (high-performance) safety light curtain systems that comply with the leading international standards/regulations. The product has built-in fingers/hands/people ...
|
|
The difference between laser sensors and photoelectric sensors – Autonicx
First, the difference in working principle
Photoelectric sensors are controlled by converting changes in light intensity into changes in electrical signals. The laser sensor first emits a laser pulse by aligning it with a laser emitting diode. After being reflected, the laser light is scattered in all directions. Partially scattered light returns to ...
|
|
Autonix thermostat TZ4ST-24R features:
Dual PID auto-adjustment function
There are high-speed response modes and slow reaction modes in the PID function.
When you want to reach the desired value quickly, use the high-speed mode (PIDF mode)
When you want to minimize overshoot, use slow mode (PIDS mode)
...
|
|
The difference between Autotonics switching power supply and module power supply
Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memory, field-programmable gate arrays (FPGAs), and other digital or analog loads. One...
|
|
Introduction to Autonix pressure sensor technology
1. Capacitive Capacitive pressure sensors are usually cleaned by a large number of OEM professional applications, testing the capacitance change between two surfaces, so that these sensors can sense the extreme pressure and vacuum level. In our typical sensor setup, the compact outer gram contains two metal exteriors, ...
|
|
Introduction to the Autonex differential pressure flow meter
The differential pressure flowmeter calculates the flow rate according to the differential pressure generated by the flow test piece installed in the pipeline, the known fluid conditions, and the size of the test piece and the pipeline.
The differential pressure flowmeter consists of a primary device (test piece) and a secondary device (differential pressure conversion and flow display) ...
|
|
Autonicx brought a full range of innovative products to the fair
On November 4, 2014, Ortonicus attended the 2014 Industrial Automation Exhibition held at the Shanghai New International Expo Center. With the theme of "high-end, intelligent and green", this exhibition has a total of CNC machine tools and metalworking exhibition, industrial automation exhibition, industrial robot exhibition, new energy and electric ...
|
|
Principle and application field of Ottonix panel table
Panel meter, also known as the dial table or meter head, the full name is the panel device instrument (panel device instrument), English Panel Meter. Because this kind of instrument device is fixed on the surface of the equipment for viewing and operation, it is called a panel table, which is a functional part of the screen equipment.
...
|
|
Position sensor key term – Ottonix
Incremental sensors
Only bearing change information is provided so that the practice bearing is unknown at startup. Each time the index is made/marks the zero or zero bit of the signaling community. Detected in the homing procedure. Regarding the commutation of brushless motors, motors generally have three magnetic Hall sensors, which are ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|
|
Rapid detection method for air conditioner thermostat – Ottonix
When the air conditioner cannot operate normally, in addition to checking the starting relay, overheating, overcurrent protector and capacitor of the compressor, it is also necessary to check the main control selection switch of the air conditioner thermostat, which is a very important control protection and actuator component in the electrical control system. Here are a few common types of air ...
|
|
Autotonix torque transducer selection
1. Selection of reliability
The potential of a sensor to persist in its properties over a period of time is called reliability. In addition to its own structure, the key factor affecting the long-term reliability of the controller is the use of harsh environments.
Harsh environments symmetrical heavy-duty sensors may lead to ...
|
|
Precautions for the use of photoelectric sensors
First, the selection of its primary consideration for the selection of three points: how wide the groove width should be; resolution (slit width); Fixation
1. The width of the slot, the detection object needs to pass through the slot of the slot-type optocoupler to block the infrared light, so the slot width of the photoelectric sensor should be wider than the detection object, and there should be a certain ...
|
|
Autonex 3-point light cross-mesh photoelectric sensor
The Ottonix sensor BWC series has selected a 3-point light cross-network detection method to reduce the detection blind spot to the maximum limit, realize the world's leading detection characteristics, and effectively prevent problems that may be caused by direct sunlight, etc., and the detection is more stable.
Up to 100 international cutting-edge ...
|
|
Load cell quality selection – Autonex
1. Observe whether the outside of the load cell is deformed or cracked. If there is any damage, please contact the manufacturer immediately.
2. Find the connection end of the sensor in the weighing controller, and measure the connection circuit of the sensor. The general excitation voltage (between EXC+ and EXC-) is 5-10V, and the output ...
|
|
Linear displacement sensor fault and treatment method - Autonics
1. If the electronic ruler is used for a long time, the seal is aging, there are many impurities, and the water mixture and oil will seriously affect the contact resistance of the brush, resulting in the continuous beating of the display. At this moment, it can be said that the electronic ruler of the linear displacement sensor is now damaged and needs to be replaced.
...
|
|
Pressure sensor influencing measurement results factor – Ottonix
Pressure is an important parameter in pneumatic, fluid or other measurements, so pressure sensors have been widely used in various experimental measurements, product testing, and automatic control systems, and the stability of the product is a major consideration when purchasing pressure sensors.
...
|
|
Autonex BD series laser displacement sensors
BD series laser displacement sensor can measure the thickness, width, horizontal difference, parallax, twist and flatness of the target object by detecting the displacement.
Regardless of the color or data of the policy, the sensor can provide accurate and stable measurement results. Sensor head and amplifier unit ...
|
|
Precautions for Temperature Sensor Installation and Use – Ottonix
1. Errors in improper introduction of devices
In other words, the thermocouple should not be installed too close to the door and the heating place, and the penetration depth should be at least 8-10 times the diameter of the maintenance tube; Maintenance of thermocouples ...
|
|
Precautions for the use of Autotonics safety light curtains
Cover the safety light curtain with your hands and observe whether the indicator light conversion is normal.
During the use of the punch photoelectric protection device, the orientation of the photoelectric protection device shall not be changed at will.
In the protection zone, the light curtain should be blocked by hand, and the machine should be able to stop the operation immediately.
...
|