1. Look at it visually.
2. Verify the sealing and preloading of the system.
3. The pressure sensor is equipped on the pressure standard equipment, including the pressurization (or vacuuming) equipment, and the pressure standard equipment with liquid as the pressure transmission medium should sweep the air in the pipeline.
4. Instruments and equipment such as pressure sensors, excitation power supplies, and reading recording equipment should be adjusted according to the regular line connection to make them in normal operating condition.
5. After the verification system is properly connected to the equipment, preheat it for half an hour, and then pressurize the verification system to the upper limit of measurement or evacuate it to the lower limit of measurement). After the pressure is stable, keep the pressure constant for more than 1 minute, and then gradually ventilate the atmosphere for 3 consecutive times. When the pressure is constant, investigate the readings of the device's indication and check the tightness of the piping system, which must not affect the leakage and shaking of the validation.
6 Indicate verification
7 view points. For pressure sensors with an accuracy level lower than 0.1 (including 0.1), at least 6 verification points (including zero) should be uniformly or reasonably selected within the measurement scaleFor pressure sensors with an accuracy level higher than 0.05 (including 0.05), at least 9 verification points (including zero) should be selected evenly or reasonably within the measurement scale. Pressure sensors.
For pressure sensors that include positive and negative pressure, you can check the positive pressure and negative pressure separately.
8. Verification method, verification from the lower limit of measurement to zero point), the Leli or a kind of straight air is steadily raised to the measurement of Leli sensor (observance), and the positive value of each verification point is recorded. The stroke output value, and then, after the hydraulic pressure is set on the upper limit of the input volume (or the lower limit of the measurement), the reverse stroke output value of the pressure sensor on the upper limit of the observation area is recorded, and then the low force (or Shengle) of the new peak is determined to the lower limit or zero of the measurement), and the reverse stroke output value of each verification point is recorded in order.
During the verification process, the voltage should be smoothly boosted or stepped down to avoid overshoot or callback.
9. The reciprocating stroke of the positive and negative stroke verification is a cycle, and the force sensor with an accuracy level of less than 0.1 (including 01) should be used for 3 cycles: the force sensor with an accuracy level higher than .05 (including 0.05) should be used for at least 4 cycles in the entire measurement scale, and the pressure sensor has m calibration points for n cycle calibration.
|
More on that
|
The difference between switching power supply and module power supply – Autonix
The two are not universal
Module power supplies are power supplies that can be mounted directly on a printed circuit board, and feature applications for application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog applications.
|
|
Classification and advantages and disadvantages of infrared sensors – Autonex
Infrared sensors include an optical system, a detection element, and a conversion circuit. Optical systems can be divided into two categories: transmissive and reflective according to different structures. According to the working principle, the detection element can be divided into thermal detection element and photoelectric detection element. The most widely used thermistors are thermistors. Thermistor...
|
|
Autonex BD series laser displacement sensors
BD series laser displacement sensor can measure the thickness, width, horizontal difference, parallax, bending, and flatness of the target object by detecting the displacement.
Regardless of the color or material, the sensor provides accurate and reliable measurement results. Sensor head and amplifier unit ...
|
|
Advantages of digital load cells – Autonex
1. The transmission interval of the digital load cell is long, the communication speed is fast, and the anti-cheating effect is remarkable; The output signal of the traditional analog load cell is small, generally millivolt level, and the signal is still lost due to the damage of the cable resistance during the transmission process, and it is also very simple to be affected by the surrounding environment.
|
|
Principle and application field of Ottonix panel table
Panel meter, also known as the dial table or meter head, the full name is the panel device instrument (panel device instrument), English Panel Meter. Because this kind of instrument device is fixed on the surface of the equipment for viewing and operation, it is called a panel table, which is a functional part of the screen equipment.
...
|
|
Autonex humidity sensor features:
Humidity sensors are divided into resistive and capacitive types, and the basic form of the product is to coat the substrate with moisture-sensitive materials to form a moisture-sensitive film. After the water vapor in the air is adsorbed on the moisture-sensitive material, the impedance and dielectric constant of the element are greatly changed, so as to make a moisture-sensitive element.
...
|
|
Pressure Sensor Fault Detection – Ottonix
First, the first component is blocked or the form of the device is wrong, and the pressure point is unreasonable, so we often emphasize that the device must be the correct device, once it is installed wrongly, or it is not well installed, it will bury endless hidden dangers for the back. What are the primary components? Orifice plates, remote transmission measuring joints, etc.
|
|
Strain characteristics of pressure sensors
When measuring the strain of an element, the strain gauge can be directly glued to the component, but if you want to measure the force, pressure, acceleration and other signals, these physical quantities must first be converted into strain, and then measured with a strain gage, and the conversion process is more than when measuring directly. The first step in completing this transformation process ...
|
|
Gas Sensor Failure Analysis – Ottonix
A gas sensor is a converter that converts the volume fraction of a gas into an electrical signal. We will inevitably encounter some problems when using gas sensors, and we have analyzed them as follows:
1. How long does it take for the gas sensor to be used and then calibrated again: the initial calibration ...
|
|
Precautions during the use of the Autonex proximity switch
1) The detected object should not touch the proximity switch, so as not to damage the proximity switch due to friction and bumping;
2) Pull the lead wire of the switch by hand will damage the switch close, and it is best to fix the lead wire with a line card at 10 cm away from the switch when the device is installed.
|
|
Autonex PSK series 2-segment display pressure sensor
The PSK1 series is a two-stage display pressure sensor that displays the current value (PV) and the set value (SV) together. It not only shows the setting status, but also provides a power-saving form and a fine-tuning function to improve the user's convenience.
PSK1 Key Features:
Additional pressure scale (composite pressure ...
|
|
Factors that contribute to sensor errors – Ortonix
The first is the offset error: since the high-frequency pressure sensor maintains a stable straight offset over the entire pressure range, the change in converter diffusion and laser adjustment correction will cause the offset error.
The second is the sensitivity error: ...
|
|
Autotonicus photoelectric switch measurement method
1. Measurement of action distance; When the action piece is close to the sensing surface close to the switch from the front, the distance close to the switch action is the action distance close to the switch, and the measured data should be within the parameters of the product.
2. Measurement of release distance
|
|
Performance Indicators and Characteristics of Load Cells – Autotonicus
Performance indicators of load cell: 1. Dynamic characteristics, 2. Linearity, 3. Hysteresis characteristicsDynamic characteristics refer to the output characteristics of the sensor when the input changes. In practice, the dynamic characteristics of a sensor are generally used to indicate how well it responds to certain specification input signals. This is because the sensing ...
|
|
Advantages of Autonix photoelectric switches
Autonics continuously improves the product function and quality, so that the product is at the international first-class level. For more than 10 years, the market share of the products in Korea has been maintained.
1. Adopt self-developed special IC ...
|
|
Otonic photoswitch determination
1. Measurement of action distance; When the action piece is close to the sensing surface close to the switch from the front, the distance close to the switch action is the action distance close to the switch, and the measured data should be within the parameters of the product.
2. Release distance ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|
|
Autonix thermostat TZ4ST-24R features:
Dual PID auto-adjustment function
There are high-speed response modes and slow reaction modes in the PID function.
When you want to reach the desired value quickly, use the high-speed mode (PIDF mode)
When you want to minimize overshoot, use slow mode (PIDS mode)
...
|
|
How to install an Autotonics voltage sensor
Voltage sensor refers to a sensor that can sense the measured voltage and convert it into a usable output signal, in a variety of detection and control systems, it is often necessary to track and collect the communication DC voltage signal that changes at high speed, and do spectrum analysis on some more complex voltage waveforms. Voltage Sensors ...
|
|
Torque Transducer Classification – Ottonix
Torque sensor is the necessary device in some products, mainly used to measure the speed and point of view, but different types of sensors, the use of methods and effects are different, so what are the classifications of torque sensors?
...
|
|