Autonics BH series photoelectric sensors
The BH series photoelectric sensors can be used with M18 fixing nuts and fixing nuts for frontal equipment, or with M3 bolts and nuts for peripheral equipment. Sensitive equipment options promise easy application in a variety of industrial environments. The sensor can be equipped with a simple wire to generate individual or simultaneous N...
|
|
The working principle of Autonex photoelectric switches
1. After the modulation pulse generated by the vibration circuit passes through the reflection circuit, the digital integration photoelectric switch or RC integration method is used to eliminate the disturbance, and finally the driver is triggered by a delay (or no delay) to output the photoelectric switch control signal.
2. Use optical elements to make the beam in the middle of the propagation medium.
|
|
Advantages of Autonix photoelectric switches
Autonics continuously improves the product function and quality, so that the product is at the international first-class level. For more than 10 years, the market share of the products in Korea has been maintained.
1. Adopt self-developed special IC ...
|
|
Ortonicx SFL/SFLA series safety light curtains
Leveraging the expertise accumulated in the development of industrial sensors, such as area sensors and mapping sensors, Ottonix has developed the SFL series (standard) and SFLA series (high-performance) safety light curtain systems that comply with the leading international standards/regulations. The product has built-in fingers/hands/people ...
|
|
Performance Indicators and Characteristics of Load Cells – Autotonicus
Performance indicators of load cell: 1. Dynamic characteristics, 2. Linearity, 3. Hysteresis characteristicsDynamic characteristics refer to the output characteristics of the sensor when the input changes. In practice, the dynamic characteristics of a sensor are generally used to indicate how well it responds to certain specification input signals. This is because the sensing ...
|
|
Autonics Solid State Relay SSR adds SR(H)2/3 three-phase
Autonics Solid State Relay SSR adds SR(H)2/3 three-phase solid state relay to its family of relays
Autonex proudly introduces you to the new formation of solid state relays, three-phase solid state relays. Compact design, flexible devices, easy ...
|
|
Wiring of the load cell – Autonex
The load cell can be wired in two different ways with input and output:
One is the four-wire connection method
The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very fast to use, but when the cable is long, it is very easy to be affected by the working temperature.
|
|
Characteristic parameters of the BJ series of Autonex photoelectric sensors
Through-beam type
BJ15M-TDT-(C)-(P) / BJ10M-TDT-(C)-(P) / BJ7M-TDT-(P)
Polarized specular reflective type
BJ3M-PDT-(C)-(P)
...
|
|
The difference between switching power supply and module power supply – Autonix
Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog loads.
|
|
The difference between laser sensors and photoelectric sensors – Autonicx
First, the difference in working principle
Photoelectric sensors are controlled by converting changes in light intensity into changes in electrical signals. The laser sensor first emits a laser pulse by aligning it with a laser emitting diode. After being reflected, the laser light is scattered in all directions. Partially scattered light returns to ...
|
|
Introduction to Torque Transducers – Autotonics
1. Characteristics
1. It can not only measure the constant motion torque, but also measure the rotational rotational distance;
2. It can measure both non-static torque and static torque;
3. High precision and good reliability; Strong anti-interference ability;
4. Light weight, very light, all kinds of ...
|
|
Autonex PSK series 2-segment display pressure sensor
The PSK1 series is a two-stage display pressure sensor that displays the current value (PV) and the set value (SV) together. It not only shows the setting status, but also provides a power-saving form and a fine-tuning function to improve the user's convenience.
PSK1 Key Features:
Additional pressure scale (composite pressure ...
|
|
Installation steps for dynamic torque transducers – Autonex
Dynamic torque transducers can be used in the manufacture of viscometers, electric (pneumatic, hydraulic) torque wrenches, which have the advantages of high precision, fast frequency response, good reliability and long life.
Installation process:
1. According to the connection form of the shaft and the length of the dynamic torque sensor, determine the original ...
|
|
Autonex proximity switch PRD/PRDW series
Autonex cylindrical remote proximity switch PRD/PRDW series, the selection of self-developed special IC, with the highest international noise immunity level, high echo frequency, low leakage current and residual voltage, the detection interval is 1.5-2 times of the original product, close to the switch and the cable connection part of the selection of strong ...
|
|
Autonex SFC series safety controllers
The SFC series of safety controllers can be used with safety input products (switches, sensors, etc.) and satisfies the self-diagnosis function and safety integrity required by safety standards. In addition, the slim design saves space in the installation and allows for the use of screwed/screwless pushes for wiring connections.
|
|
The difference between sensitivity, resolution, and accuracy of a sensor
sensitivity
Concept: It refers to the ratio of the change of output △y to the change of input △x in the case of steady-state operation of the sensor, that is, the ratio of the dimension of output and input.
Sensor sensitivity is the slope of the output-input characteristic curve. If the output and input of the sensor ...
|
|
Ottonix sensor type
Sensors are the most fundamental and commonly used components in automation systems. Autonex offers a wide range of sensors including proximity switches, photoelectric sensors, fiber optic sensors, and pressure sensors, which are committed to maximizing the user's work efficiency.
...
|
|
The difference between Autotonics switching power supply and module power supply
Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memory, field-programmable gate arrays (FPGAs), and other digital or analog loads. One...
|
|
Rapid detection method for air conditioner thermostat – Ottonix
When the air conditioner cannot operate normally, in addition to checking the starting relay, overheating, overcurrent protector and capacitor of the compressor, it is also necessary to check the main control selection switch of the air conditioner thermostat, which is a very important control protection and actuator component in the electrical control system. Here are a few common types of air ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|