KUKA robot repair and replacement of the main engine of the control system:
It is necessary to keep the KUKA robot control system in a state of shutdown and power failure, and do a good job of relevant inspection and personal maintenance work, so as to prevent the robot from restarting without permission, and ensure that the robot's buffer is in a closed state; Plug the power supply of the feed cable. Special attention should be paid to the white wire with a voltage of 400V when the main switch of the robot is turned off, and the risk of electric shock should be noted when replacing.
The operation process of the KUKA robot repair and replacement control system host:
(1) Open the door of the robot control cabinet;
(2) Use a mobile phone to take pictures of the connection line of the control host, and unplug the interface, power supply and all plug connections of the robot control system;
(3) Disassemble the main engine to transport the safety bolt and put down the knurled nut;
(4) The main engine of the dismantled robot control system is pulled up and taken out;
(5) the new robot control system host is loaded and fixed, and the various plugs of the host of the control system are reconnected according to the preserved photos.
|
More on that
|
KUKA teach pendant programming
(1) Teach: P6, P7, P8, P9, HOME
Refer to P4 and teach P6 with LIN command: P3, P2 and Pl respectively, and teach P7, P8 and pg with PTP command; Return to the HOME point with the PTP command as shown, the end of the machine ...
|
|
Germany Borgward officially signed a contract with KUKA Robotics
On June 21, at the International Robotics and Automation Skills Expo (AUTOMATICA) in Munich, Germany, Germany's Borgward Car Group, a well-known car manufacturer, and KUKA Robotics Co., Ltd., a world-leading industrial robot manufacturer, officially signed a memorandum of understanding on strategic cooperation. Germany...
|
|
The role of KUKA robot dresspack
1. The robot pipeline includes cable harnesses, robot SMB lines, robot communication lines and robot connection lines as communication, power supply cables and optical fibers. The product has excellent properties such as high heat resistance, oil resistance, bending resistance, impact resistance, and insulation.
...
|
|
Introduction to KUKA foundry robots
KUKA foundry robots are equipped with high-temperature, corrosion-resistant, acid-and-alkali resistant coatings, which are particularly suitable for the harsh environments of the foundry and forging industry.
Forming, casting and machining: KUKA foundry robots are all-rounders in the foundry and forging industry.
KUKA foundry robot can be used in casting and forging ...
|
|
KUKA gets hands-on experience with medical robotics
When a robot assists in the care of patients as a component of a medical device, the robot is closely monitored: this is now possible in KUKA's new 3D virtual showroom. It's all about simulating an operating room with three animated robots. With just a few clicks, the ...
|
|
Classification of KUKA robot models and types
General industrial robots are classified according to centralized standards:
1. Classification according to the number of axes. according to
2. Classification according to the application scenario. For example: welding, palletizing, etc.
Let's talk about KUKA machine in the early years ...
|
|
KUKA robot resolver-to-digital converter
KUKA robot resolver-to-digital converters (RDCs) are used to collect motor orientation data. Up to 8 resolvers can be connected to the RDC. In addition, the temperature of the motor is measured and analyzed. EDS is used to store non-volatile data in RDC bins.
...
|
|
Calibration of industrial robots and positioners – KUKA robots
Manipulator positioners are generally divided into compound positioners, single-axis positioners, double-axis positioners and three-axis positioners according to the number of components of the drive motor. Before and during the welding operation of the robotic arm, the positioner loads and locates the welded workpiece by clamping the stuff.
|
|
Industrial robot system composition - KUKA robot
Generally speaking, industrial robots are composed of three major parts and six subsystems. The three major parts are the mechanical part, the sensing part and the control part. The six subsystems can be divided into mechanical structure system, drive system, perception system, robot-environment interaction system, human-computer interaction system and control system.
|
|
Introduction to the principle of KUKA robots
description
1 Robots
2 Control cabinet
3 Motor cable X30
4 Data cable X31
5 Motor cable X20
6 Data Cable X21
7 Grounding cable 16 mm²
8 Power supply 400 V 3 - X1
...
|
|
Handling robot classification - KUKA robots
The transfer robot is a manipulator in practical work, and the manipulator is developed because its positive role is increasingly known:
First, it can partially replace manual operation;
Second, it can follow the requirements of the production process, follow the certain procedures, time...
|
|
KUKA robot application examples
Berthold Hermle AG is one of the world's leading manufacturers of milling machines and machining centers. When it comes to the automation of its machining centers, Hermle relies on the expertise of KUKA Roboter GmbH from Augsburg. In the new production system RS 4, the company ...
|
|
Introduction to the internal structure and system of KUKA industrial robots
KUKA Industrial Robot System Introduction, KUKA Robot Co., Ltd. was founded in 1898 in Augsburg, Bavaria, Germany, and is one of the world's leading industrial robot manufacturers. KUKA Robotics has more than 20 subsidiaries around the world, most of which are sales and service centers, ...
|
|
The difference between KUKA robot inverter and servo manipulator
The servo manipulator controls the manipulator's actions through servo motors and servo drives. The servo manipulator has higher control accuracy than the frequency conversion manipulator and is expensive.
Inverter manipulator is an automatic production equipment that can imitate some functions of the upper limbs of the human body, and can be automatically controlled according to predetermined requirements.
|
|
Understand the hangar card robot from the analysis of load, accuracy and range
Carrying talents: Speak with strength
The range of mass within which the robot can stand in any direction within its operating range. The load of the robot depends not only on the mass of the load, but also on the speed and direction of the robot. Bearer capacity refers to the load-bearing capacity when running at high speed. Bearing ability is not ...
|
|
Classification of vision systems for mobile robots – KUKA robots
The vision system of mobile robot refers to the vision system of mobile robot, which includes two parts: obtaining pictures through sensors and processing drawings through computer processors. According to the number and characteristics of vision sensors, the mobile robot vision system of the main stream has monocular vision, binocular ...
|
|
The use of logical functions in robot programs – KUKA robots
Inputs and outputs are used for logic programming, and digital and analog inputs and outputs can be used for communication with the peripherals of the robot control system.
When programming the KUKA robot, the ...
|
|
KUKA robot MFC3+DSE card 00-117-336 is faulty
Fault 1: When loading a software component, the control system is stuck.
Cause: The MFC device cannot be initialized, MFC3 is not properly plugged in, and the PCI bus on the motherboard is faulty.
Solution: Remove the PC card, boot the PC, check the MFC3 slot, and replace the control system PC.
...
|
|
KUKA robot power-on configuration instructions
The wiring and clarification of the corresponding interface are as follows:
1. X1 connector: power supply interface of control cabinet.
(1) KR C4 stand & KR C4 Midsize & KR C4 Extend: three-phase four-wire system, 380V AC AC;
...
|
|
KUKA robot partial learning operation steps
Perform "bias learning" with loads. The difference from the first zero calibration is stored.
1. Place the robot in the pre-zero calibration position
2. In the main menu, select the zero calibration > EMD > with load correction > > deviation ...
|
|