That wisdom Fujiyue information SHOW
Nachi Fujikoshi robot debugging steps Nachi Fujikoshi robot debugging steps

1. Come over every day to check whether the position of the pallet and the position of the manipulator have been moved. There is no problem, plug in the manipulator power supply, switching power supply. 2. Turn on the computer, select program 429, start from step 0, check the moderate speed, and then execute it sequentially. Until the manipulator moves to a ...

Precautions when inspecting Nachi robots Precautions when inspecting Nachi robots

Workers who perform inspections, etc., are required to observe the following rules. (A) If work is performed outside the operation area of the robot, please determine the content of the work in advance. In any case, work outside the robot's operating area. (B) In principle, the robot ...

Nazhi robot debugging steps Nazhi robot debugging steps

1. Come over every day to check whether the position of the pallet and the position of the manipulator have been moved. There is no problem, plug in the manipulator power supply, switching power supply. 2. Turn on the computer, select program 429, start from step 0, check the moderate speed, and then execute it sequentially. Until the manipulator moves to a ...

The robot flexible gripper The robot flexible gripper

1. With this flexible gripper, the robot can respond sensitively to workpieces of various shapes. Objects such as boxes, shafts, special-shaped workpieces, etc. can be grasped without having to replace other grippers! 2. This flexible gripper is driven by servo motor, which can ...

Advantages of the Nachifukoshi compact superspeed robot MZ04 Advantages of the Nachifukoshi compact superspeed robot MZ04

Clever cable arrangement for hollow wrists The robot cable is intelligently wired by means of a hollow wrist*. By simplifying the interspersed wiring to avoid interference with surrounding devices, the reliability of the equipment has been greatly improved. Compact, wide range of action Lightweight and compact ...

The basic reason why the Chi Fuji Yue robot teach pendant will be presented The basic reason why the Chi Fuji Yue robot teach pendant will be presented

The basic reasons why the Chi Fuji Yue robot teach pendant will be presented: 1. The teaching screen is black or there is no display. 2. The robot teach pendant is turned on, the horizontal screen and the vertical screen are not displayed well. 3. I can't enter the system when I turn it on. 4. Alarm when the machine is turned on or in operation. 5. Emergency stop press ...

Nazhi Robot: How to deal with the failure of the arc welding robot Nazhi Robot: How to deal with the failure of the arc welding robot

1. Some phenomena generally presented by welding robot welding Our common robot welding generally uses carbon dioxide gas maintenance welding, and the welding defects presented in the welding process generally include welding deviation, undercut, porosity, etc., the specific analysis is as follows: (1) Present welding deviation ...

Common faults of Nazhi robots and their handling methods Common faults of Nazhi robots and their handling methods

Nazhi Robot: Common faults and repair methods of industrial robots: 1. Is the robot contactor noisy? Reason: It is likely to be caused by the uneven contact surface of the contactor, and the appearance is sand or rust. As a result, it will cause a lack of phase, which will lead to contactors, switching frequency conversion and other components.

Analysis and diagnosis of the black screen fault of the MC50 teaching board Analysis and diagnosis of the black screen fault of the MC50 teaching board

1. Whether the power supply of the robot teach pendant is connected. Check whether the power supply of the Nazhi robot teach pendant is connected to the power supply and whether there is a short circuit in the power connection. 2. Whether the brightness, contrast and display position knobs of the Nazhi robot teach pendant are adjusted in the normal position. Will the robot teach ...

Nazhi robot pose position modification Nazhi robot pose position modification

When the robot is grabbed or placed, there will be a relatively fixed or fixed position, which needs to be positioned for the first time or the offset needs to be corrected during use. Keep in mind that the posture point is not the same as the normal teaching point, and it cannot be operated using the normal teaching point method. As shown in the figure below, the 17 lines of instructions ...

What should I do if the robot is ready to run and the button light does not flash What should I do if the robot is ready to run and the button light does not flash

Before using the robot teach pendant to operate the robot to move or rotate, it is generally necessary to press the work preparation button to make the work preparation light shine! After the work preparation light is on, the staff can move on to the next step. But there are times when ...

The items that the Nachi Fujikoshi robot regularly inspects and maintains The items that the Nachi Fujikoshi robot regularly inspects and maintains

The items that the Nachi Fujikoshi robot regularly inspects and maintains Daily viewing Confirm the function of the button and the teach pendant operation button Control the cleaning of the entire equipment, etc 3 months viewing Cool the presence or absence of dust on the fan Robot connection cable, teach pendant ...

Nachi Fujikoshi - self-aligning roller bearings Nachi Fujikoshi - self-aligning roller bearings

Generally, rolling bearings can be divided into ball bearings or roller bearings according to the type of rolling elements, and when classified by balls and rollers, they can be further divided into cylindrical roller bearings, tapered roller bearings, spherical roller bearings and needle roller bearings. characteristic High axial load resistance ...

Nazhi robot fault code and solution Nazhi robot fault code and solution

Error Code 1052: Instability Detected in Sequential Circuit (External E-Stop) Cause: This fault occurs when an instability or abnormality is detected in the replication signal circuit used for external emergency stop. Solution: Please check whether only one signal is entered, or if the ...

Nachi PHV series travel motor Nachi PHV series travel motor

Small size The structure of the hydraulic motor, hydraulic operation valve, and reducer is integrated, and the walking part is miniaturized Adapts to high-speed movements The 2-speed travel motor is used to increase the movement speed It can be used in a wide range of applications, from powerful work to high-speed movement Smooth ...

Nazhi PVD series piston pump Nazhi PVD series piston pump

Features of PVD series piston pumps: Compact Easy to use The internal oil drain structure does not need an oil drain pipe, and the pump is simple to exhaust Get the most out of your engine Constant power control for mini excavators is standard Multiple choices Can be combined with 1 or 2 ...

Interface button customization Interface button customization

Enter the constant setting Set the constant in the T/P key T/P key to select software equipment (teach-in form) The corresponding function code can be entered in the interface of the software equipment (teaching form), and the effect of the function code can be checked in the code list In the first one enter ...

Expert mode settings for Nachi bots Expert mode settings for Nachi bots

Expert mode settings The robot system is divided into several user levels: INTEGRATOR, SPECIALIST, and USER, and the user permission levels we commonly use are generally SPECIALIST and USER 2. After the robot is powered on and running, the default user level of the system is USE...

Nazhi robot sets the language Nazhi robot sets the language

After adding the language to the system or the system already has the language we need, you can set the corresponding interface language. The following figure shows how to set the teach pendant interface language from the English interface to the Chinese interface:   Press the R key with the teach pendant keyboard in the main interface, call up the R function command, and enter 348 ...

Nachi robot monitor settings Nachi robot monitor settings

Monitor settings Sometimes, when more than two window monitors are displayed on the screen at the same time or all the window monitors are closed, it is required to open a new window monitor from the system so that the window monitor can display relevant information such as program and status. Open more than 2 windows together to monitor ...

Nazhi robot constant setting Nazhi robot constant setting

Enter the constant setting Set Constant: Select the mechanical constant The range of action is selected as a mechanical constant Set the limit data of the corresponding axis according to the actual working condition of the robot

Next Page »
1234Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top