1. The measurement is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity.
2. There are no obstruction moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. There is a common adaptability to slurry measurement.
3. Reasonable selection of sensor lining and electrode materials, that is, good corrosion resistance and wear resistance.
4. The converter adopts a novel excitation method, with low power consumption, zero point stability and high accuracy. The flow range can reach the standard value.
5. The converter can be integrated with the sensor or separated.
6. The converter uses 16-bit high-performance microprocessor, which is convenient for parameter setting and reliable for programming.
7. The flowmeter is a two-way measurement system, which is equipped with three accumulation calculators: forward total, reverse total and difference total; It can display positive and negative flow and has a variety of outputs: current, pulse, digital communication, HART.
8. The converter adopts surface mounting technology, which has the functions of self-test and self-diagnosis.
9. The measurement accuracy is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity, and the sensor induced voltage signal has a linear relationship with the average flow velocity, so the measurement accuracy is high.
10. There is no flow obstruction in the measurement pipeline, so there is no additional pressure loss; There are no moving parts in the measuring pipe, so the sensor has an extremely long life.
|
More on that
|
External factors influencing the failure of the Rosemount 3051 transmitter
1. The impulse tube is faulty
There are two simplest problems with the pressure duct of the Rosemount 3051 transmitter, which is blockage and leakage of the pressure duct. Once this problem is presented, the most obvious manifestation is that the leakage surface index of the impulse pipe will be abnormal.
|
|
The difference between a Rosemount transmitter and a Siemens transmitter
The difference between Siemens' transmitter and Rosemount's transmitter: Siemens' transmitter is a piezoresistive pressure transmitter, and Rosemount's transmitter is a capacitive pressure transmitter.
The transmitter converts the output signal of the sensor into a signal that can be recognized by the controller.
|
|
Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter
1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected.
2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...
|
|
Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:
Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:
Advanced diagnosis
Advanced diagnosis provides ongoing process monitoring to ensure the integrity and security of the process environment. The Statistical Process Monitoring (SPM) skill alerts you to deal with issues and anomalies. This comprehensive ...
|
|
What to look out for before using a Rosemount transmitter
Rosemount transmitters can be used in many different fields, and different people face different situations and problems when using transmitters. Then the editor will introduce these problems to us.
How to clear the Rosemount transmitter ...
|
|
How the Rosemount transmitter is wired
During the use of the Rosemount transmitter, wire the Rosemount transmitter according to the following steps:
1. Take out the Rosemount 3051 and remove the electronic enclosure marked "FIELD TERMINALS".
2. Will be positive ...
|
|
Fault Judgment in Rosemount Differential Pressure Transmitter Applications
Fault judgment and analysis in the application
In the process of measuring the transmitter, there are often some problems, and the timely analysis and treatment of faults are crucial for the ongoing production According to the experience of daily maintenance, some of the analysis methods and analysis methods are summarized and summarized.
|
|
The Rosemount Twisted Square thermowell avoids wake shedding
When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...
|
|
Precautions for use of Rosemount differential pressure transmitters
Rosemount differential pressure transmitter in daily use we should pay attention to something, take Rosemount transmitter 3051DP differential pressure transmitter as an example, Rosemount differential pressure transmitter has a coplanar differential pressure transmitter and a flat mounted differential pressure transmitter in use The principle is the same, but the installation ...
|
|
Installation requirements for Rosemount transmitter impulse tubing
The effect of the pressure impulse pipe is to transmit the pressure of the process medium to the transmitter to measure, in order to obtain accurate measurement values for the process measurement. There are many details that need to be paid attention to at the time of the installation, and the following summarizes the Luo ...
|
|
The installation environment affects the use of Rosemount transmitters
If you want to get better measurement results in practical applications, you need to pay attention to the following environmental issues when installing:
1. The Rosemount transmitter pressure impulse pipe should be arranged in a place where the temperature fluctuation is small, and the buffer tube (disk) should be connected when measuring steam or other low-temperature medium.
|
|
How to choose the Rosemount 3051DP differential pressure transmitter
1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure.
2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA.
...
|
|
Types of Rosemount transmitters
The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or grouper) for setting the transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant.
|
|
A method for verifying a current loop signal for a Rosemount pressure transmitter
The Rosemount pressure transmitter uses a 4-20mA signal, which is the conversion value of the output generated by the pressure transmitter. The output of the transmitter is detected according to the HART protocol, however, it is converted to a proportional current so that it can be visualized as a reading. Normally, at zero level output, the transmitter displays 4mA ...
|
|
Rosemount transmitter signal line grounding method
If the Rosemount transmitter does not have alarms and safety adjustment options installed, the transmitter will typically operate according to the default alarm settings, i.e., the alarm condition is set to "high" and the safety is set to "off". Then proceed as follows:
1. ...
|
|
The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is
1. Look at whether the diaphragm is damaged, if not, after removing it, press it with chopsticks after imitating the power on in the room to see if there is a pressure display, if there is a display change, you can only disassemble another one, see if the transmitter module is broken, because the transmitter modules are integrated ...
|
|
Rosemount transmitters feature two-way communication
The intelligent Rosemount transmitter is composed of a sensor and a microprocessor (microcomputer), which makes full use of the computing and storage capabilities of the microprocessor to process the data of the sensor, including the conditioning of the measurement signal (such as filtering, amplification, A/D conversion, etc.), data display, etc.
|
|
Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide
1.Rosemount 2088
Install it directly to the impulse pipe without the need for an additional mounting bracket, or use the optional mounting bracket to mount it directly to a wall, panel, or 2" pipe.
2. Rosemount 2090P
Use of existing welded short casings ...
|
|
An indispensable accessory for Rosemount transmitters
Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type:
Threading ...
|
|
Key Features of the Rosemount 248 Temperature Transmitter:
Top mount and rail mount applications provide 2-year stability.
The integrated LCD meter provides easy indication of the process and diagnostic indications.
Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings.
Polished stainless steel housing can be applied to ...
|
|