1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected.
2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be an equal diameter straight pipe section of not less than 15D (D is the pipe diameter) in the upstream of the flowmeter, and an equal diameter straight pipe section of not less than 5D in the downstream.
3. If there is a gradual expansion pipe in the upstream of the flowmeter installation point, there should be an equal diameter straight pipe section of not less than 18D (D is the pipe diameter) in the upstream of the flowmeter, and an equal diameter straight pipe section of not less than 5D in the downstream.
4. If there is a 90° elbow or downward joint upstream of the flowmeter installation point, there should be an equal diameter straight pipe section of not less than 20D upstream of the flowmeter, and an equal diameter straight pipe section of not less than 5D in the downstream.
5. If there is a 90° elbow on the same plane upstream of the flowmeter installation point, there should be an equal diameter straight pipe section of not less than 25D upstream of the flowmeter, and an equal diameter straight pipe section of not less than 5D downstream.
6. The flow regulating valve or pressure regulating valve should be installed at a distance of 5D downstream of the flowmeter as far as possible, if it must be installed in the upstream of the flowmeter, the upstream of the flowmeter should have an equal diameter straight pipe section of not less than 25D, and the downstream should have an equal diameter straight pipe section of not less than 5D.
7. If there is a piston or piston pump, piston or roots fan or compressor in the upstream of the flowmeter, there should be an equal diameter straight pipe section of not less than 25D in the upstream of the flowmeter, and an equal diameter straight pipe section of not less than 5D in the downstream
|
More on that
|
The meaning of the Rosemount transmitter fault code indication
Press Limit: The process variable read out by the transmitter is not within the transmitter range, which means that the range of the set volume exceeds the range of the transmitter cassette, and the solution is to replace the transmitter cassette.
Temp Limit: ...
|
|
What are the features of the Rosemount 644 temperature transmitter?
1. It can greatly reduce the cost of wire and labor.
2. The advanced diagnosis function can reduce the number of on-site repairs.
3. Order a complete temperature transmitter and temperature sensing assembly to simplify setup, specifications, and ordering, and then reduce costs.
4. Adopt HART communication protocol. ...
|
|
The installation environment affects the use of Rosemount transmitters
If you want to get better measurement results in practical applications, you need to pay attention to the following environmental issues when installing:
1. The Rosemount transmitter pressure impulse pipe should be arranged in a place where the temperature fluctuation is small, and the buffer tube (disk) should be connected when measuring steam or other low-temperature medium.
|
|
Fault Judgment in Rosemount Differential Pressure Transmitter Applications
Fault judgment and analysis in the application
In the process of measuring the transmitter, there are often some problems, and the timely analysis and treatment of faults are crucial for the ongoing production According to the experience of daily maintenance, some of the analysis methods and analysis methods are summarized and summarized.
|
|
Key Features of the Rosemount 248 Temperature Transmitter:
Top mount and rail mount applications provide 2-year stability.
The integrated LCD meter provides easy indication of the process and diagnostic indications.
Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings.
Polished stainless steel housing can be applied to ...
|
|
In 2018, the Rosemount electromagnetic flowmeter received new certification
In 2018, NAMUR passed the technical certification, and the Rosmont 8700 series electromagnetic flowmeters were finally certified by NAMUR, allowing automation products to better enter the European chemical market
The Germany Committee for Measurement and Control Standards "designates NAMUR as a standard, which is based on industrial ...
|
|
Features of the Rosemount 8732E Electromagnetic Flowmeter:
1. The measurement is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity.
2. There are no obstruction moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. There is a common adaptability to slurry measurement.
3. Reasonable selection of sensor lining and electrode materials, ...
|
|
How to solve the problem that the Rosemount transmitter cannot be powered on
Analysis and countermeasures when the Rosemount transmitter cannot be powered on.
1. There is something wrong with the leakage circuit breaker itself
When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...
|
|
Types of Rosemount transmitters
The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or grouper) for setting the transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant.
|
|
The Rosemount Twisted Square thermowell avoids wake shedding
When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...
|
|
Factors to consider when sizing the Rosemount 3051 pressure transmitter
Pressure transmitter selection
According to different application scenarios and needs, we should show practicality and economy in the selection of Rosemount pressure transmitters, and can select technical parameters from the requirements of pressure type, measuring scale, measurement medium, accuracy, applicable temperature scale, etc.
...
|
|
Features of the Rosemount 8732E Electromagnetic Flowmeter:
Features of the Rosemount 8732E Electromagnetic Flowmeter
1. The measurement is not affected by the changes in fluid density, viscosity, temperature, pressure and conductivity.
2. There are no blocking moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. It has unique adaptability to slurry measurement.
...
|
|
The Rosemount flow meter indicates the cause of the failure
During the long-term use of the Rosemount flowmeter, there may be some problems in the manual: 1. The manual is not accurate for a long time; 2. There are always no signs; 3. It means that the fluctuation range is large and there is no reading; 4. The indication does not return to zero; 5. There is no indication when the flow rate is small; 6. When the large flow indicates that the positive ...
|
|
Rosemount 3051S direct-attach pressure transmitter
The Rosemount 3051S direct-attach pressure transmitter is a professional-class solution for optimized functionality. This scalable SuperModule™ platform reduces process variation and reduces protection, making it particularly useful for gauge and absolute pressure measurement in Rosemont transmitters. Should...
|
|
How to choose a Rosemount transmitter for standard accuracy
Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...
|
|
How the Rosemount 3051 pressure transmitter works
The 3051 pressure transmitter is used to measure the level, density, and pressure of liquids, gases, or vapors, and then convert the pressure signal into a 4-20mADC signal output. There are mainly capacitive pressure transmitters and diffusion silicon pressure transmitters, ceramic pressure transmitters, strain gauge pressure transmitters, etc.
...
|
|
Factors to consider when installing a Rosemount 644 temperature transmitter
Rosemount 644 temperature transmitter must be considered when installing the factors, only we solve these unfavorable factors, in the installation of the Rosemount temperature transmitter will not encounter some unnecessary things
routine
Electrical temperatures such as RTDs and thermocouples ...
|
|
Rosemount transmitter signal line grounding method
If the Rosemount transmitter does not have alarms and safety adjustment options installed, the transmitter will typically operate according to the default alarm settings, i.e., the alarm condition is set to "high" and the safety is set to "off". Then proceed as follows:
1. ...
|
|
Installation of Rosemount transmitter attachments
The Rosemount transmitter is an important accessory in the use of time and time and time components, which will also affect the accuracy of the transmitter measurement results. Therefore, in order to prevent the occurrence of measurement errors, we need to pay attention to the following points in the equipment process of additional equipment.
1. Rosemont ...
|
|
An indispensable accessory for Rosemount transmitters
Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type:
Threading ...
|
|