The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or integrator) for setting transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant setting, and self-diagnosis.
The software of the digital Rosemount transmitter includes a system program and a functional module, which refers to the management of each part of the circuit of the transmitter hardware, and enables the transmitter to complete the most basic functions, such as the conversion of analog signals and digital signals, data communication, transmitter self-testing, etc. Functional modules: resource module variable conversion, damping time setting analog input, display conversion, range automatic switching calculation function, nonlinear calibration PID, control function and temperature error calibration alarm.
The transmitter includes range adjustment, zero adjustment and zero migration. The linearization and transmitter signal transmission methods make the upper limit of the output signal of the transmitter correspond to the upper limit of the measurement scale, and the range adjustment is equivalent to the slope of the input and output characteristics of the change transmitter, that is, the ratio factor between the output signal y of the transmitter and the input signal x of the change transmitter.
|
More on that
|
Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:
Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:
Advanced diagnosis
Advanced diagnosis provides ongoing process monitoring to ensure the integrity and security of the process environment. The Statistical Process Monitoring (SPM) skill alerts you to deal with issues and anomalies. This comprehensive ...
|
|
Rosemount 3051S direct-attach pressure transmitter
The Rosemount 3051S direct-attach pressure transmitter is a professional-class solution for optimized functionality. This scalable SuperModule™ platform reduces process variation and reduces protection, making it particularly useful for gauge and absolute pressure measurement in Rosemont transmitters. Should...
|
|
Rosemount transmitters are affected by the angle of inclination of the installation
The actual working performance of the Rosemount transmitter will be affected by the angle of inclination, ambient temperature, static pressure and fluid temperature of the device.
|
|
Features and performance of Rosemount pressure sensors
Features and performance of Rosemount pressure sensors
1. Diffusion silicon pressure sensor
The working principle of the diffusion silicon pressure sensor is that the pressure of the measured medium acts directly on the diaphragm of the sensor (stainless steel or ceramic), so that the diaphragm produces a micro-displacement proportional to the pressure of the medium, ...
|
|
How to choose a Rosemount transmitter for standard accuracy
Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...
|
|
Features of the Rosemount 8732E Electromagnetic Flowmeter:
Features of the Rosemount 8732E Electromagnetic Flowmeter
1. The measurement is not affected by the changes in fluid density, viscosity, temperature, pressure and conductivity.
2. There are no blocking moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. It has unique adaptability to slurry measurement.
...
|
|
Key Features of the Rosemount 248 Temperature Transmitter:
Top mount and rail mount applications provide 2-year stability.
The integrated LCD meter provides easy indication of the process and diagnostic indications.
Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings.
Polished stainless steel housing can be applied to ...
|
|
The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is
1. Look at whether the diaphragm is damaged, if not, after removing it, press it with chopsticks after imitating the power on in the room to see if there is a pressure display, if there is a display change, you can only disassemble another one, see if the transmitter module is broken, because the transmitter modules are integrated ...
|
|
What factors affect the performance of the Rosemount 3051 differential pressure transmitter?
1. Effect of temperature
Rosemount differential pressure transmitters will vary greatly in process temperature, ambient temperature, and will certainly differ from the reference conditions when the transmitter is tested, which also means that the functionality will be different from the reference accuracy presented. Temperature on differential pressure transmitters ...
|
|
How the Rosemount 3051TG pressure transmitter works
The Rosemount 3051TG pressure transmitter is one of the most commonly used products in the Rosemount 3051 pressure transmitter that has been tested in the power industry for 40 years. Planning with high reliability, transient stability, and easy protection. Rosemount pressure transmitters are designed from planning to installation, from protection to operation.
|
|
The difference between a Rosemount transmitter and a Siemens transmitter
The difference between Siemens' transmitter and Rosemount's transmitter: Siemens' transmitter is a piezoresistive pressure transmitter, and Rosemount's transmitter is a capacitive pressure transmitter.
The transmitter converts the output signal of the sensor into a signal that can be recognized by the controller.
|
|
In 2018, the Rosemount electromagnetic flowmeter received new certification
In 2018, NAMUR passed the technical certification, and the Rosmont 8700 series electromagnetic flowmeters were finally certified by NAMUR, allowing automation products to better enter the European chemical market
The Germany Committee for Measurement and Control Standards "designates NAMUR as a standard, which is based on industrial ...
|
|
An indispensable accessory for Rosemount transmitters
Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type:
Threading ...
|
|
How to maintain the United States rosemount3051 pressure transmitter
Rosemount pressure transmitters often have some common faults in the whole process of accurate measurement, and the immediate judgment and resolution of common faults is especially important for the manufacturing that has been carried out. According to the work experience in the usual maintenance, people have summarized and sorted out some ...
|
|
Rosemount temperature transmitter performance improvements
The fundamental function of the Rosemount 644 temperature transmitter is to make serious improvements based on extensive user feedback and application sensitivity requirements in various industries.
1. Power terminal placement: Now the power supply and communication terminal are placed at the bottom right of the equipment, and the LCD can be carried out without removing the LCD.
|
|
Features of Rosemount pressure transmitters:
The main features of Rosemount pressure transmitters are as follows:
1. It has the function of converting high and low pressure side:
The conversion function of the high and low voltage side of this sensor is mainly through the adjustment of the internal parameters of the handheld communicator, and the useful data on the high and low voltage side is realized.
|
|
Problems to be noted when calibrating Rosemount transmitters
1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA.
2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.
|
|
Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide
1.Rosemount 2088
Install it directly to the impulse pipe without the need for an additional mounting bracket, or use the optional mounting bracket to mount it directly to a wall, panel, or 2" pipe.
2. Rosemount 2090P
Use of existing welded short casings ...
|
|
How to solve the problem that the Rosemount transmitter cannot be powered on
Analysis and countermeasures when the Rosemount transmitter cannot be powered on.
1. There is something wrong with the leakage circuit breaker itself
When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...
|
|
How the Rosemount transmitter is wired
During the use of the Rosemount transmitter, wire the Rosemount transmitter according to the following steps:
1. Take out the Rosemount 3051 and remove the electronic enclosure marked "FIELD TERMINALS".
2. Will be positive ...
|
|