1. The impulse tube is faulty
There are two simplest problems with the pressure duct of the Rosemount 3051 transmitter, which is blockage and leakage of the pressure duct. Once this problem is presented, the most obvious manifestation is that the leakage appearance index of the impulse tube will show an abnormal situation. Accordingly, the impulse pipe should be inspected to find out the cause and further investigate.
2. The three-valve group is blocked
Whether it is the three-valve group or the pressure impulse pipe blockage meter will not appear, the correct way is to remove the three-valve group, and see, if the meter head has appeared to prove that the three-valve group is blocked, if the three-valve group has not appeared after dismantling, it is the pressure impulse pipe blockage.
3. The ground is wet or produces lightning strikes
Once lightning strikes or excessive humidity occurs, it will cause abnormal use of the Rosemount 3051 transmitter. If the customer chooses the transmitter with lightning protection, then don't worry too much. It is necessary for users to be clear in the process of use that such problems are usually caused by power supply problems or circuit problems. Therefore, before solving this problem, it is necessary to take a detailed look at the power supply status and the expansion circuit so that the transmitter can find out where the transmitter is wrong.
4. The circuit is overheated
Once the Rosemount 3051 transmitter has the problem of circuit overheating, the components of the circuit conversion part will simply show problems due to the influence of high temperature, and in serious cases, it will also cause damage.
5. The power supply switch is closed or the voltage is abnormal
The Rosemount 3051 transmitter encountered this situation and needed to resort to a multimeter thing. The first thing to look at is the status of the power supply, and if a problem is found, it needs to be carefully acknowledged. Generally speaking, the main causes of abnormal conditions include tripping, power supply problems, and so on.
|
More on that
|
What to do if the Rosemount pressure transmitter measurement is inaccurate
Common Rosemount pressure transmitter measurement incorrect situations:
1. The input impedance of the Rosemount transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A)Ω if necessary, if it does not match, corresponding measures can be adopted according to its differences: such as increasing the power supply ...
|
|
Rosemount transmitter installation requirements and how to install it
Rosemount transmitters must be installed in a constant temperature environment, which is also determined by the characteristics of the flange transmitter. Because the measured medium of ordinary transmitters generally enters the transmitter measurement chamber through the impulse tube. If the measurement is a viscous liquid medium, it will be easier to form a conductive ...
|
|
The Rosemount 3051 transmitter has its own advantages
1. The five-year stable soil is 0.125%, which can greatly reduce the cost of verification and protection.
2. Faster dynamic response, which can reduce the variability of the process.
3. The co-plane planning can realize a comprehensive measurement scheme.
4. Compact and lightweight coplanar planning with the best function ...
|
|
Rosemount transmitters are affected by the angle of inclination of the installation
The actual working performance of the Rosemount transmitter will be affected by the angle of inclination, ambient temperature, static pressure and fluid temperature of the device.
|
|
Features that Rosemount Instrument Thermowells have
Rosemount Instrument Heat Jacket has the following features:
1. Similar tags – when presenting some similar applications that only need to be changed slightly, it should be possible to imitate the application value of a specific tag, and then there is no need to re-enter the repetitive information, only change the variables that need to be changed in the new use.
|
|
Features of the Rosemount 8732E Electromagnetic Flowmeter:
Features of the Rosemount 8732E Electromagnetic Flowmeter
1. The measurement is not affected by the changes in fluid density, viscosity, temperature, pressure and conductivity.
2. There are no blocking moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. It has unique adaptability to slurry measurement.
...
|
|
How to choose the Rosemount 3051DP differential pressure transmitter
1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure.
2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA.
...
|
|
The difference between a Rosemount transmitter and a Siemens transmitter
The difference between Siemens' transmitter and Rosemount's transmitter: Siemens' transmitter is a piezoresistive pressure transmitter, and Rosemount's transmitter is a capacitive pressure transmitter.
The transmitter converts the output signal of the sensor into a signal that can be recognized by the controller.
|
|
How the Rosemount transmitter is wired
During the use of the Rosemount transmitter, wire the Rosemount transmitter according to the following steps:
1. Take out the Rosemount 3051 and remove the electronic enclosure marked "FIELD TERMINALS".
2. Will be positive ...
|
|
Installation requirements for Rosemount transmitter impulse tubing
The effect of the pressure impulse pipe is to transmit the pressure of the process medium to the transmitter to measure, in order to obtain accurate measurement values for the process measurement. There are many details that need to be paid attention to at the time of the installation, and the following summarizes the Luo ...
|
|
The Rosemount 3051 transmitter resets the range
There are three ways to reset the range of the 3051 transmitter:
1. Use only the communicator to reset the range
HART communicator shortcut keys 4 or 5. The simplest and most common way to reset the range using only the communicator is to change the values that mimic points 4 and 20 mA independently, without the need for pressure inputs.
|
|
What are the main advantages of Rosemount temperature transmitters?
What are the main advantages of Rosemount temperature transmitters?
1. Only by adapting to harsh environments can it be strong
Rosemount temperature transmitters generally work in a wide range of environments, from extremely cold to extremely hot areas, many of which work in the open air.
|
|
An indispensable accessory for Rosemount transmitters
Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type:
Threading ...
|
|
Rosemount 3051S direct-attach pressure transmitter
The Rosemount 3051S direct-attach pressure transmitter is a professional-class solution for optimized functionality. This scalable SuperModule™ platform reduces process variation and reduces protection, making it particularly useful for gauge and absolute pressure measurement in Rosemont transmitters. Should...
|
|
Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide
1.Rosemount 2088
Install it directly to the impulse pipe without the need for an additional mounting bracket, or use the optional mounting bracket to mount it directly to a wall, panel, or 2" pipe.
2. Rosemount 2090P
Use of existing welded short casings ...
|
|
Rosemount 3051 transmitter mounting
What are the factors that affect the functionality of the Rosemount 3051 differential pressure transmitter? What are the factors that affect the functionality of the Rosemount 3051 differential pressure transmitter? Unique to Rosemount, the typical North and South American device method, the head-mounted 3051 transmitter with threaded sensors.
1. Heat ...
|
|
Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method
Rosemount differential pressure transmitter zero point adjustment
Before zeroing, admit that the balancing valve is nearly open, and use a flathead screwdriver to turn the zeroing screw. The clockwise conditioning output increases, the counterclockwise conditioning output decreases, and the zeroing resolution can reach 0.01% of the set range.
|
|
The Rosemount flow meter indicates the cause of the failure
During the long-term use of the Rosemount flowmeter, there may be some problems in the manual: 1. The manual is not accurate for a long time; 2. There are always no signs; 3. It means that the fluctuation range is large and there is no reading; 4. The indication does not return to zero; 5. There is no indication when the flow rate is small; 6. When the large flow indicates that the positive ...
|
|
What to look out for before using a Rosemount transmitter
Rosemount transmitters can be used in many different fields, and different people face different situations and problems when using transmitters. Then the editor will introduce these problems to us.
How to clear the Rosemount transmitter ...
|
|
The Rosemount Twisted Square thermowell avoids wake shedding
When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...
|
|