Precautions for use of Rosemount differential pressure transmitters

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

Rosemount differential pressure transmitter in daily use we should pay attention to something, take Rosemount transmitter 3051DP differential pressure transmitter as an example, Rosemount differential pressure transmitter has a coplanar differential pressure transmitter and plane mounted differential pressure transmitter in use The principle is the same, but the installation method is different, we should avoid some simple and easy to wrong operation methods in daily use.
Precautions for use of Rosemount differential pressure transmitters

1. Do not touch the barrier diaphragm with your hands, or do not touch the reasonable diaphragm with a hard object, which will cause the barrier diaphragm to be damaged and the sensor to be broken.

2. If the waist of the differential pressure transmitter is loose, do not twist it hard, there is an Allen screw on the side of the waist, use a wrench to twist it, if you twist the waist by hand, the cable in the sensor will be broken, so that the sensor will be broken.

3. Rosemount differential pressure transmitter can also measure pressure, such as 3051CD.3051CG gauge pressure transmitter, differential pressure transmitter has 2 holes, plugging one hole can measure pressure.

4. The power supply should not be applied to the differential transmitter transmitter with a voltage higher than 36V, which will cause damage to the transmitter.

5. When measuring steam or other high-temperature medium, the temperature should not exceed the limit temperature of the transmitter by 85 degrees, and it is necessary to use heat dissipation devices, such as condensation bends, to cool down if it is higher than the limit temperature of the transmitter.

6. When measuring steam or other high-temperature media, heat pipes should be used to connect the transmitter and pipes together, and the pressure on the pipes should be transmitted to the transformer. When the measured medium is water vapor, an appropriate amount of water should be injected into the heat pipe to prevent the overheated steam from directly touching the transmitter and damaging the sensor.

7. The temperature of the measured medium should not be too low, if it is too low to freeze, it will damage the barrier diaphragm of the sensor element, resulting in damage to the transmitter, if necessary, the temperature of the transmitter should be protected to prevent freezing.

8. In the process of pressure transmission, the following points should be noted,

a. Do not leak air at the connection between the Rosemount differential pressure transmitter and the heat pipe;

b. Before starting to use, if the valve is closed, the valve should be opened very carefully, slowly and gently to avoid direct impact of the measured medium on the sensor diaphragm, thereby damaging the sensor diaphragm.

c. It is necessary to keep the pipeline unblocked, the sediment in the pipeline will pop out, and damage the sensor diaphragm, if the barrier diaphragm shows scratches, the diaphragm is damaged, and the pressure value will be inaccurate and jump.

More on that
Factors to consider when installing a Rosemount 644 temperature transmitter Factors to consider when installing a Rosemount 644 temperature transmitter

Rosemount 644 temperature transmitter must be considered when installing the factors, only we solve these unfavorable factors, in the installation of the Rosemount temperature transmitter will not encounter some unnecessary things routine Electrical temperatures such as RTDs and thermocouples ...

How the Rosemount transmitter is wired How the Rosemount transmitter is wired

During the use of the Rosemount transmitter, wire the Rosemount transmitter according to the following steps: 1. Take out the Rosemount 3051 and remove the electronic enclosure marked "FIELD TERMINALS". 2. Will be positive ...

Rosemount temperature transmitter performance improvements Rosemount temperature transmitter performance improvements

The fundamental function of the Rosemount 644 temperature transmitter is to make serious improvements based on extensive user feedback and application sensitivity requirements in various industries. 1. Power terminal placement: Now the power supply and communication terminal are placed at the bottom right of the equipment, and the LCD can be carried out without removing the LCD.

What factors affect the performance of the Rosemount 3051 differential pressure transmitter? What factors affect the performance of the Rosemount 3051 differential pressure transmitter?

1. Effect of temperature Rosemount differential pressure transmitters will vary greatly in process temperature, ambient temperature, and will certainly differ from the reference conditions when the transmitter is tested, which also means that the functionality will be different from the reference accuracy presented. Temperature on differential pressure transmitters ...

Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method

Rosemount differential pressure transmitter zero point adjustment   Before zeroing, admit that the balancing valve is nearly open, and use a flathead screwdriver to turn the zeroing screw. The clockwise conditioning output increases, the counterclockwise conditioning output decreases, and the zeroing resolution can reach 0.01% of the set range.

Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter

1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected. 2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...

The Rosemount 3051 transmitter is prone to some failures The Rosemount 3051 transmitter is prone to some failures

1. The pressure of the 3051 transmitter does not go up to the output of the transmitter, the output of the pressurized transmitter does not change, and the output of the pressure transmitter changes suddenly, and the zero position of the pressure relief transmitter cannot be returned. In this case, you should see if the pressure interface is leaking or blocked, and after looking at the wiring method and power supply, ...

Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

Eight ways to maintain your Rosemount 3051 pressure transmitter Eight ways to maintain your Rosemount 3051 pressure transmitter

1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit. 2. When wiring, pass the cable through the waterproof joint or winding pipe and tighten the sealing nut to prevent rain from leaking through the cable.

How the Rosemount 3051TG pressure transmitter works How the Rosemount 3051TG pressure transmitter works

The Rosemount 3051TG pressure transmitter is one of the most commonly used products in the Rosemount 3051 pressure transmitter that has been tested in the power industry for 40 years. Planning with high reliability, transient stability, and easy protection. Rosemount pressure transmitters are designed from planning to installation, from protection to operation.

Three types of Rosemount 3051 transmitters Three types of Rosemount 3051 transmitters

There are many types of Rosemount 3051 transmitters, and there are many types, today we will tell you about the most basic 3 types of transmitters of Rosemount 3051 transmitters, absolute pressure, gauge pressure, and differential pressure. 3051CA Absolute Pressure Transmitter Rosemount Reference Pressure When the Pressure is Vacuum, the ...

In 2018, the Rosemount electromagnetic flowmeter received new certification In 2018, the Rosemount electromagnetic flowmeter received new certification

In 2018, NAMUR passed the technical certification, and the Rosmont 8700 series electromagnetic flowmeters were finally certified by NAMUR, allowing automation products to better enter the European chemical market The Germany Committee for Measurement and Control Standards "designates NAMUR as a standard, which is based on industrial ...

Rosemount transmitter signal line grounding method Rosemount transmitter signal line grounding method

If the Rosemount transmitter does not have alarms and safety adjustment options installed, the transmitter will typically operate according to the default alarm settings, i.e., the alarm condition is set to "high" and the safety is set to "off". Then proceed as follows: 1. ...

Summary of problems in the use of the Rosemount 3051 transmitter Summary of problems in the use of the Rosemount 3051 transmitter

1. What kind of output signal does the Rosemount transmitter need to obtain: mV, V, mA and frequency output digital output, and the choice of what kind of output depends on a variety of factors, including the separation between the Rosemount transmitter and the system controller or display, whether there is "noise" or other electronic interference signals.

What causes inaccurate measurements in Rosemount pressure transmitters What causes inaccurate measurements in Rosemount pressure transmitters

Rosemount Pressure Transmitter Inaccurate Measurement Causes:   1. Whether the power supply of the Rosemount pressure transmitter is normal, if it is less than 12VDC, you should check whether there is a large load in the circuit, and the input impedance of the transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A...

How to maintain the Rosemount 3051 pressure transmitter How to maintain the Rosemount 3051 pressure transmitter

United States rosemount 3051 pressure transmitter maintenance is mainly divided into two points:   1. In the whole process of accurate measurement, some common faults often occur in the Rosemount pressure transmitter, and the immediate judgment and analysis and resolution of common faults are especially important for the production and manufacturing that has been carried out.

Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements

For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed 1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...

An indispensable accessory for Rosemount transmitters An indispensable accessory for Rosemount transmitters

Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type: Threading ...

Rosemount transmitter pressure gauges are widely used Rosemount transmitter pressure gauges are widely used

Rosemount transmitters are used in industrial process control and technical measurement processes, because the elastic and sensitive elements of mechanical pressure gauges have high mechanical strength and easy production, so that mechanical pressure gauges are more and more widely used.   Rosemont ...

How to solve the problem of Rosemount differential pressure transmitter migration failure How to solve the problem of Rosemount differential pressure transmitter migration failure

The migration of differential pressure transmitters is a form of application, which refers to the process of artificially moving the measuring point of a differential pressure transmitter from the zero point to the required value. The migration of differential pressure transmitters includes two major contents: positive migration and negative migration.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top