How to choose the Rosemount 3051DP differential pressure transmitter

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure.
How to choose the Rosemount 3051DP differential pressure transmitter

2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA.

3. The output of the transmitter is 4-20MA, and the digital signal based on HART protocol is adopted.

4. Select the type of process flange, which is generally coplanar, as well as flange material, and exhaust valve material.

5. Select the material of the wetted diaphragm, there are 2 options, one 316 stainless steel and the other alloy C-276.

6.The standard of O-ring is glass filling,

7. The sensor filling fluid is silicone oil and inert oil.

8. The shell material is generally aluminum shell, and there are 2 kinds of electrical interfaces: 1/2-14NPT and M20*1.5.

9.The HART version is generally HR5 version.

10. Mounting bracket for more on-site use selection code.

11. Product certification, there are 11 kinds of certification, choose the certification type according to the on-site requirements.

12. Choose M5 is with gauge,
More on that
Rosemount transmitter pressure gauges are widely used Rosemount transmitter pressure gauges are widely used

Rosemount transmitters are used in industrial process control and technical measurement processes, because the elastic and sensitive elements of mechanical pressure gauges have high mechanical strength and easy production, so that mechanical pressure gauges are more and more widely used.   Rosemont ...

Rosemount 3051 transmitter mounting Rosemount 3051 transmitter mounting

What are the factors that affect the functionality of the Rosemount 3051 differential pressure transmitter? What are the factors that affect the functionality of the Rosemount 3051 differential pressure transmitter? Unique to Rosemount, the typical North and South American device method, the head-mounted 3051 transmitter with threaded sensors. 1. Heat ...

The meaning of the Rosemount transmitter fault code indication The meaning of the Rosemount transmitter fault code indication

Press Limit: The process variable read out by the transmitter is not within the transmitter range, which means that the range of the set volume exceeds the range of the transmitter cassette, and the solution is to replace the transmitter cassette.   Temp Limit: ...

Factors to consider when installing a Rosemount 644 temperature transmitter Factors to consider when installing a Rosemount 644 temperature transmitter

Rosemount 644 temperature transmitter must be considered when installing the factors, only we solve these unfavorable factors, in the installation of the Rosemount temperature transmitter will not encounter some unnecessary things routine Electrical temperatures such as RTDs and thermocouples ...

Features that Rosemount Instrument Thermowells have Features that Rosemount Instrument Thermowells have

Rosemount Instrument Heat Jacket has the following features:   1. Similar tags – when presenting some similar applications that only need to be changed slightly, it should be possible to imitate the application value of a specific tag, and then there is no need to re-enter the repetitive information, only change the variables that need to be changed in the new use.

What causes inaccurate measurements in Rosemount pressure transmitters What causes inaccurate measurements in Rosemount pressure transmitters

Rosemount Pressure Transmitter Inaccurate Measurement Causes:   1. Whether the power supply of the Rosemount pressure transmitter is normal, if it is less than 12VDC, you should check whether there is a large load in the circuit, and the input impedance of the transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A...

Key Features of the Rosemount 248 Temperature Transmitter: Key Features of the Rosemount 248 Temperature Transmitter:

Top mount and rail mount applications provide 2-year stability. The integrated LCD meter provides easy indication of the process and diagnostic indications. Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings. Polished stainless steel housing can be applied to ...

Installation of Rosemount transmitter attachments Installation of Rosemount transmitter attachments

The Rosemount transmitter is an important accessory in the use of time and time and time components, which will also affect the accuracy of the transmitter measurement results. Therefore, in order to prevent the occurrence of measurement errors, we need to pay attention to the following points in the equipment process of additional equipment.   1. Rosemont ...

The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is

1. Look at whether the diaphragm is damaged, if not, after removing it, press it with chopsticks after imitating the power on in the room to see if there is a pressure display, if there is a display change, you can only disassemble another one, see if the transmitter module is broken, because the transmitter modules are integrated ...

Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements

For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed 1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...

That's how Rosemount transmitters should be selected That's how Rosemount transmitters should be selected

Rosemount transmitter selection requires a good transmitter before use, so its selection is very important 1. According to the pressure interface mode Generally, threaded connection is the standard interface method. 2. According to the required accuracy level Measurement error of the transmitter ...

The Rosemount 3051 transmitter cannot be powered on The Rosemount 3051 transmitter cannot be powered on

The Rosemount 3051 transmitter will not be powered on or may damage the transmitter after it is placed in the tripping device. When our technicians have understood these problems, they have analyzed and made corresponding countermeasures from three aspects, as follows: Rosemont ...

Rosemount Pressure Transmitter Measurement Principle Rosemount Pressure Transmitter Measurement Principle

The Rosemount pressure transmitter measurement principle progresses as follows: 1. The pressure transmitter transmits the pressure on the high and low pressure sides to the movable (sensing) diaphragm in the center of the sensor through silicone oil. 2. The movable diaphragm undergoes a slight displacement under the effect of differential pressure, so that the movable (sensing) membrane ...

The Rosemount 3051 transmitter has its own advantages The Rosemount 3051 transmitter has its own advantages

1. The five-year stable soil is 0.125%, which can greatly reduce the cost of verification and protection. 2. Faster dynamic response, which can reduce the variability of the process. 3. The co-plane planning can realize a comprehensive measurement scheme. 4. Compact and lightweight coplanar planning with the best function ...

Summary of problems in the use of the Rosemount 3051 transmitter Summary of problems in the use of the Rosemount 3051 transmitter

1. What kind of output signal does the Rosemount transmitter need to obtain: mV, V, mA and frequency output digital output, and the choice of what kind of output depends on a variety of factors, including the separation between the Rosemount transmitter and the system controller or display, whether there is "noise" or other electronic interference signals.

An indispensable accessory for Rosemount transmitters An indispensable accessory for Rosemount transmitters

Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type: Threading ...

The Rosemount 3051 transmitter is prone to some failures The Rosemount 3051 transmitter is prone to some failures

1. The pressure of the 3051 transmitter does not go up to the output of the transmitter, the output of the pressurized transmitter does not change, and the output of the pressure transmitter changes suddenly, and the zero position of the pressure relief transmitter cannot be returned. In this case, you should see if the pressure interface is leaking or blocked, and after looking at the wiring method and power supply, ...

How to maintain the Rosemount 3051 pressure transmitter How to maintain the Rosemount 3051 pressure transmitter

United States rosemount 3051 pressure transmitter maintenance is mainly divided into two points:   1. In the whole process of accurate measurement, some common faults often occur in the Rosemount pressure transmitter, and the immediate judgment and analysis and resolution of common faults are especially important for the production and manufacturing that has been carried out.

Eight ways to maintain your Rosemount 3051 pressure transmitter Eight ways to maintain your Rosemount 3051 pressure transmitter

1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit. 2. When wiring, pass the cable through the waterproof joint or winding pipe and tighten the sealing nut to prevent rain from leaking through the cable.

External factors influencing the failure of the Rosemount 3051 transmitter External factors influencing the failure of the Rosemount 3051 transmitter

1. The impulse tube is faulty There are two simplest problems with the pressure duct of the Rosemount 3051 transmitter, which is blockage and leakage of the pressure duct. Once this problem is presented, the most obvious manifestation is that the leakage surface index of the impulse pipe will be abnormal.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top