The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

1. Look at whether the diaphragm is damaged, if not, after removing it, press it with chopsticks after imitating the power on in the room to see if there is a pressure display, if there is a display change, you can only disassemble another one, and see if the transmitter module is broken, because the transmitter modules are integrated, if it is broken, it can only be replaced with a new one.
The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is

2, Rosemount's transmitter and its simple electromagnetic disturbance, see if there is large electrical equipment near the transmitter, even the 3051 line must be grounded, the field transmitter is also best to do a grounding, and then use HART to communicate, if it is not possible, string a 250 ohm resistor on the line and then log in, if it is still inaccessible, it may be that the meter is broken.

3. If there is a capillary, the capillary oil leakage may also present this situation, and it can be returned to the factory for inspection.

4. In winter, the time-part pressure variable measurement medium freezes. Expansion causes FAIL MOUDLE fault display, output maximum current, processing method: replace the new meter, return the old one to the factory for repair! In summer, the meter head is seriously flooded, and the FAIL MOUDLE is displayed. At this time, the replacement electronic module will display normal.
More on that
Features of the Rosemount 8732E Electromagnetic Flowmeter: Features of the Rosemount 8732E Electromagnetic Flowmeter:

1. The measurement is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity. 2. There are no obstruction moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. There is a common adaptability to slurry measurement. 3. Reasonable selection of sensor lining and electrode materials, ...

Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

How to solve the problem that the Rosemount transmitter cannot be powered on How to solve the problem that the Rosemount transmitter cannot be powered on

Analysis and countermeasures when the Rosemount transmitter cannot be powered on. 1. There is something wrong with the leakage circuit breaker itself When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...

External factors influencing the failure of the Rosemount 3051 transmitter External factors influencing the failure of the Rosemount 3051 transmitter

1. The impulse tube is faulty There are two simplest problems with the pressure duct of the Rosemount 3051 transmitter, which is blockage and leakage of the pressure duct. Once this problem is presented, the most obvious manifestation is that the leakage surface index of the impulse pipe will be abnormal.

How to maintain the United States rosemount3051 pressure transmitter How to maintain the United States rosemount3051 pressure transmitter

Rosemount pressure transmitters often have some common faults in the whole process of accurate measurement, and the immediate judgment and resolution of common faults is especially important for the manufacturing that has been carried out. According to the work experience in the usual maintenance, people have summarized and sorted out some ...

Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements

For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed 1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...

Types of Rosemount transmitters Types of Rosemount transmitters

The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or grouper) for setting the transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant.

Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method

Rosemount differential pressure transmitter zero point adjustment   Before zeroing, admit that the balancing valve is nearly open, and use a flathead screwdriver to turn the zeroing screw. The clockwise conditioning output increases, the counterclockwise conditioning output decreases, and the zeroing resolution can reach 0.01% of the set range.

How to solve the problem of Rosemount differential pressure transmitter migration failure How to solve the problem of Rosemount differential pressure transmitter migration failure

The migration of differential pressure transmitters is a form of application, which refers to the process of artificially moving the measuring point of a differential pressure transmitter from the zero point to the required value. The migration of differential pressure transmitters includes two major contents: positive migration and negative migration.

Rosemount transmitter pressure gauges are widely used Rosemount transmitter pressure gauges are widely used

Rosemount transmitters are used in industrial process control and technical measurement processes, because the elastic and sensitive elements of mechanical pressure gauges have high mechanical strength and easy production, so that mechanical pressure gauges are more and more widely used.   Rosemont ...

Precautions for use of Rosemount differential pressure transmitters Precautions for use of Rosemount differential pressure transmitters

Rosemount differential pressure transmitter in daily use we should pay attention to something, take Rosemount transmitter 3051DP differential pressure transmitter as an example, Rosemount differential pressure transmitter has a coplanar differential pressure transmitter and a flat mounted differential pressure transmitter in use The principle is the same, but the installation ...

Installation of Rosemount transmitter attachments Installation of Rosemount transmitter attachments

The Rosemount transmitter is an important accessory in the use of time and time and time components, which will also affect the accuracy of the transmitter measurement results. Therefore, in order to prevent the occurrence of measurement errors, we need to pay attention to the following points in the equipment process of additional equipment.   1. Rosemont ...

Features and performance of Rosemount pressure sensors Features and performance of Rosemount pressure sensors

Features and performance of Rosemount pressure sensors 1. Diffusion silicon pressure sensor The working principle of the diffusion silicon pressure sensor is that the pressure of the measured medium acts directly on the diaphragm of the sensor (stainless steel or ceramic), so that the diaphragm produces a micro-displacement proportional to the pressure of the medium, ...

A summary of methods for on-site inspection of Rosemount transmitter failures A summary of methods for on-site inspection of Rosemount transmitter failures

When something goes wrong with the Rosemount transmitter, you can first use the common methods of on-site inspection to check it, such as: query method: recall the ignition, smoke, odor, power supply change, lightning strike, wetting, misoperation, and mismaintenance before the fault occurs; Intuitive method: investigate external damage to the circuit, leakage of the impulse pipe, ...

What factors affect the performance of the Rosemount 3051 differential pressure transmitter? What factors affect the performance of the Rosemount 3051 differential pressure transmitter?

1. Effect of temperature Rosemount differential pressure transmitters will vary greatly in process temperature, ambient temperature, and will certainly differ from the reference conditions when the transmitter is tested, which also means that the functionality will be different from the reference accuracy presented. Temperature on differential pressure transmitters ...

How Rosemount pressure transmitters work How Rosemount pressure transmitters work

1. The working principle of Rosemount pressure transmitter When the Rosemount pressure transmitter operates, the process pressure is transferred to the filling fluid by the isolation diaphragm and filling fluid on the high and low pressure sides, which in turn transfers the pressure to the sensing diaphragm in the center of the sensor. The sensing diaphragm is a tensioned ...

Key Features of the Rosemount 248 Temperature Transmitter: Key Features of the Rosemount 248 Temperature Transmitter:

Top mount and rail mount applications provide 2-year stability. The integrated LCD meter provides easy indication of the process and diagnostic indications. Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings. Polished stainless steel housing can be applied to ...

Rosemount differential pressure transmitter selection considerations Rosemount differential pressure transmitter selection considerations

The following points should be considered in the selection of differential pressure transmitters: 1. Measure the scale, the accuracy of the demand and the measurement function; 2. Measure the environment of the outer surface, such as the industrial environment of petrochemical industry, the existence of flammable, toxic and explosive risk atmosphere, and the high ambient temperature; 3 tested ...

Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter

1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected. 2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...

In 2018, the Rosemount electromagnetic flowmeter received new certification In 2018, the Rosemount electromagnetic flowmeter received new certification

In 2018, NAMUR passed the technical certification, and the Rosmont 8700 series electromagnetic flowmeters were finally certified by NAMUR, allowing automation products to better enter the European chemical market The Germany Committee for Measurement and Control Standards "designates NAMUR as a standard, which is based on industrial ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top