When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In less complex cases, it may be necessary to make a small change, such as increasing the wall thickness by one or two millimeters or shortening the penetration length without changing the predetermined measurement orientation. In complex cases, a completely different solution may be argued, such as a non-touch temperature measurement solution, such as Emerson's Rosemount X-well design, or a Rosemount Twisted Square spiral thermowell that is resistant to eddy current-induced oscillation.
The Rosemount Twisted Square thermowell has a unique shape that prevents the common wake-off problem. There is no need for a specific orientation at the time of piercing, and the need for overly thick thermowells and large-diameter process perforations is reduced. It eliminates the need for thick thermowells and prevents the undesirable effects on echo times, and can be adapted to different operating parameters. Its slight shape can disrupt the composition of a long vortex, causing it to form on both sides, so that they tend to balance and cancel each other out. The result is much smaller oscillations, in some cases down to 90 percent, and spiral structures like this one can be successfully used in ducts and deep-sea risers.
|
More on that
|
What to look out for before using a Rosemount transmitter
Rosemount transmitters can be used in many different fields, and different people face different situations and problems when using transmitters. Then the editor will introduce these problems to us.
How to clear the Rosemount transmitter ...
|
|
Rosemount transmitters feature two-way communication
The intelligent Rosemount transmitter is composed of a sensor and a microprocessor (microcomputer), which makes full use of the computing and storage capabilities of the microprocessor to process the data of the sensor, including the conditioning of the measurement signal (such as filtering, amplification, A/D conversion, etc.), data display, etc.
|
|
That's how Rosemount transmitters should be selected
Rosemount transmitter selection requires a good transmitter before use, so its selection is very important
1. According to the pressure interface mode
Generally, threaded connection is the standard interface method.
2. According to the required accuracy level
Measurement error of the transmitter ...
|
|
How to choose a Rosemount transmitter for standard accuracy
Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...
|
|
How to solve the problem that the Rosemount transmitter cannot be powered on
Analysis and countermeasures when the Rosemount transmitter cannot be powered on.
1. There is something wrong with the leakage circuit breaker itself
When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...
|
|
Features and performance of Rosemount pressure sensors
Features and performance of Rosemount pressure sensors
1. Diffusion silicon pressure sensor
The working principle of the diffusion silicon pressure sensor is that the pressure of the measured medium acts directly on the diaphragm of the sensor (stainless steel or ceramic), so that the diaphragm produces a micro-displacement proportional to the pressure of the medium, ...
|
|
Rosemount transmitters are affected by the angle of inclination of the installation
The actual working performance of the Rosemount transmitter will be affected by the angle of inclination, ambient temperature, static pressure and fluid temperature of the device.
|
|
Fault Judgment in Rosemount Differential Pressure Transmitter Applications
Fault judgment and analysis in the application
In the process of measuring the transmitter, there are often some problems, and the timely analysis and treatment of faults are crucial for the ongoing production According to the experience of daily maintenance, some of the analysis methods and analysis methods are summarized and summarized.
|
|
Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements
For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed
1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...
|
|
How to maintain and clean the Rosemount 3051DP differential pressure transmitter
After a period of use, the Rosemount 3051DP differential pressure transmitter needs to be cleaned regularly to maintain the accuracy of the differential pressure transmitter and achieve the desired function. Generally, the differential pressure transmitter should be cleaned in the following order:
1. Close the high-voltage side ...
|
|
What is the difference between a Siemens transmitter and a Rosemount transmitter
Differences between Siemens transmitters and Rosemount transmitters: Siemens' transmitters are piezoresistive pressure transmitters, while Rosemount's transmitters are capacitive pressure transmitters.
The transmitter converts the output signal of the sensor into other signals that can be recognized by the controller.
|
|
Installation requirements for Rosemount transmitter impulse tubing
The effect of the pressure impulse pipe is to transmit the pressure of the process medium to the transmitter to measure, in order to obtain accurate measurement values for the process measurement. There are many details that need to be paid attention to at the time of the installation, and the following summarizes the Luo ...
|
|
How the Rosemount 3051 pressure transmitter works
The 3051 pressure transmitter is used to measure the level, density, and pressure of liquids, gases, or vapors, and then convert the pressure signal into a 4-20mADC signal output. There are mainly capacitive pressure transmitters and diffusion silicon pressure transmitters, ceramic pressure transmitters, strain gauge pressure transmitters, etc.
...
|
|
Three types of Rosemount 3051 transmitters
There are many types of Rosemount 3051 transmitters, and there are many types, today we will tell you about the most basic 3 types of transmitters of Rosemount 3051 transmitters, absolute pressure, gauge pressure, and differential pressure.
3051CA Absolute Pressure Transmitter Rosemount Reference Pressure When the Pressure is Vacuum, the ...
|
|
A method for verifying a current loop signal for a Rosemount pressure transmitter
The Rosemount pressure transmitter uses a 4-20mA signal, which is the conversion value of the output generated by the pressure transmitter. The output of the transmitter is detected according to the HART protocol, however, it is converted to a proportional current so that it can be visualized as a reading. Normally, at zero level output, the transmitter displays 4mA ...
|
|
Problems to be noted when calibrating Rosemount transmitters
1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA.
2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.
|
|
Installation of Rosemount transmitter attachments
The Rosemount transmitter is an important accessory in the use of time and time and time components, which will also affect the accuracy of the transmitter measurement results. Therefore, in order to prevent the occurrence of measurement errors, we need to pay attention to the following points in the equipment process of additional equipment.
1. Rosemont ...
|
|
The meaning of the Rosemount transmitter fault code indication
Press Limit: The process variable read out by the transmitter is not within the transmitter range, which means that the range of the set volume exceeds the range of the transmitter cassette, and the solution is to replace the transmitter cassette.
Temp Limit: ...
|
|
The installation environment affects the use of Rosemount transmitters
If you want to get better measurement results in practical applications, you need to pay attention to the following environmental issues when installing:
1. The Rosemount transmitter pressure impulse pipe should be arranged in a place where the temperature fluctuation is small, and the buffer tube (disk) should be connected when measuring steam or other low-temperature medium.
|
|
How Rosemount Electromagnetic Flowmeters Troubleshoot Air Ducts
Rosemount Electromagnetic Flowmeter Eliminates Empty Pipe ProblemRosemount Electromagnetic Flowmeter Eliminates Empty Pipe Problem
If the ATC detection is unexpected, the following measures can be adopted:
1. Make sure the sensor is overflowing.
2. Ensure that the measuring electrode has not been installed on the top of the pipe of the sensor.
...
|
|