Rosemount/Rosemount
Left boxProduct DisplayRight box
  • Rosemount/Rosemount 96 Thermowell Material Certified
  • Rosemount Dissolved Oxygen Sensor 499ADO Operating Pressure 0-65psig
  • Rosemount/Rosemount Level Transmitter 3302 Operating temperature -40—150°C
  • Rosemount Flanged Electromagnetic Flowmeter Sensor 8705015 15-900mm diameter
  • The Rosemount/Rosemount In-Line Oxygen Analyzer CX1100 outputs 4-20mA
  • Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341208
  • Rosemount/Rosemount Vortex Flow Meter 8800DW020 outputs 4-20mA
  • Rosemount/Rosemount Thin Slice Vortex Flow Meter 8800DW005 with a turndown ratio of 38:01:00
  • The Rosemount/Rosemount Fixed Gas Detection Transmitter 925 outputs 4-20mA
  • Rosemount/Rosemount Controller 3491 input: 4-20 mA
  • Rosemount/Rosemount Electromagnetic Flowmeter Sensor MS240 Reference Accuracy±0.25%
  • Rosemount/Rosemount Temperature Sensor 214C 24AWG Leads
  • Rosemount/Rosemount replacement probe Oxymitter™ 4000 communication protocol 4-20mA
  • Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721005
  • Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707200 Power Supply 115VAC
  • Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 Turndown ratio 38:01:00
  • Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424
  • Rosemount/Rosemount X-STREAM Enhanced XEFD Continuous Gas Analyzer
  • Rosemount/Rosemount Conductivity Sensor 400VP Contact
  • Rosemount/Rosemount Wireless Discrete Dual Input Transmitter 702 Materials: Low copper, aluminum, or stainless steel
  • Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381224
  • The Rosemount/Rosemount Continuous Gas Analyzer XEGP enclosure is IP20 rated
  • The Rosemount/Rosemount Low Flow Conductivity Sensor 404 cable is 3.1m in standard length
  • The Rosemount/Rosemount Transmitter 3051S has a differential pressure of up to 2000 psi
  • Rosemount Flanged Vortex Flow Meter 8800DF120
  • The Rosemount/Rosemount Chip Electromagnetic Flowmeter Sensor 8711 has a turndown ratio of 13:1
  • Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381212
  • Rosemount/Rosemount General Purpose pH/ORP Sensor 389
  • Rosemount/Rosemount 3144P Temperature Transmitter Large LCD display
  • Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341224
  • Rosemount/Rosemount Retractable pH/ORP Sensor 398R
  • Rosemount Flanged Vortex Flow Meter 8800DF020
  • Rosemount/Rosemount Wireless Integrated Orifice Flowmeter 3051CFP tubing sizes range from 15 to 40mm
  • Rosemount/Rosemount In-Line Oxygen Analyzer 6888A Ambient temperature -40 to 70°C
  • Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381210
  • Rosemount/Rosemount Level Transmitter 5408 1450 psi working pressure
  • Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341204
  • The Rosemount/Rosemount Temperature Transmitter 644 outputs 4-20mA
  • The Rosemount/Rosemount Vortex Flow Meter 8800 has a turndown ratio of 15.1
  • Rosemount/Rosemount Multi-Instrument Flange MIF-61 Accuracy±2mm
  • Rosemount/Rosemount Temperature Transmitter 2240S 4-wire stand-alone line
  • The Rosemount/Rosemount Pressure Transmitter 3152K has a 10:1 turndown ratio
  • The Rosemount/Rosemount Wall Mount Electromagnetic Flowmeter Transmitter 8712E consumes up to 15W
  • Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341724
  • The Rosemount/Rosemount plunger probes the discrete transmitter 702 in place
  • Rosemount/Rosemount Electromagnetic Flowmeter Sensor MS160 Pipe size 80-900mm
  • Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flow Meter USM341230
  • Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707240 Power consumption 300W
  • Rosemount/Rosemount Level Transmitter 3051L Pressure 20.68 bar
  • Rosemount/Rosemount Continuous Gas Analyzer XECLD
line Last next sign
Left boxBrand ProfileRight box
Rosemount/RosemountRosemount is a world-renowned instrumentation company that includes a comprehensive range of pressure, temperature, flow, level, and safety measurement instruments. Rosemount process instrumentation has a wider range of applications throughout the process control industry.

For more than 100 years, Emerson has been recognized as a world leader in the design and manufacture of products for a range of pressure, temperature, flow and level instrumentation products. With 4 times the competition's customer satisfaction ratings, Rosemount is also a world leader in customer service.

The success of Rosemount products is based on a consistent commitment to product quality and reliability in the harshest industrial environments, as evidenced by the worldwide customer preference.

Rosemount has always believed in the concept of continuous improvement; This is the cornerstone of ensuring that we are a market leader in technology and value. As a world-class leader, Rosemount is committed to meeting and exceeding the needs of its customers, resulting in more than 97% of the customers it serves re-esteeming Rosemount products.

Rosemount pressure, temperature, level, and flow measurement technology shortens project execution cycles and reduces costs. Over the life of the instrument, it can help customers increase uptime, reduce power generation costs, minimize fuel costs, and enhance environmental friendliness.
Left boxBrand NewsRight box
How to choose the Rosemount 3051DP differential pressure transmitter
How to choose the Rosemount 3051DP differential pressure transmitter
1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure. 2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA. ...
What are the features of the Rosemount 644 temperature transmitter?
What are the features of the Rosemount 644 temperature transmitter?
1. It can greatly reduce the cost of wire and labor. 2. The advanced diagnosis function can reduce the number of on-site repairs. 3. Order a complete temperature transmitter and temperature sensing assembly to simplify setup, specifications, and ordering, and then reduce costs. 4. Adopt HART communication protocol. ...

What causes inaccurate measurements in Rosemount pressure transmitters
What causes inaccurate measurements in Rosemount pressure transmitters
Rosemount Pressure Transmitter Inaccurate Measurement Causes:   1. Whether the power supply of the Rosemount pressure transmitter is normal, if it is less than 12VDC, you should check whether there is a large load in the circuit, and the input impedance of the transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A...

Rosemount Pressure Transmitter Measurement Principle
Rosemount Pressure Transmitter Measurement Principle
The Rosemount pressure transmitter measurement principle progresses as follows: 1. The pressure transmitter transmits the pressure on the high and low pressure sides to the movable (sensing) diaphragm in the center of the sensor through silicone oil. 2. The movable diaphragm undergoes a slight displacement under the effect of differential pressure, so that the movable (sensing) membrane ...

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top