Yaskawa servo motor - common faults and maintenance methods of servo drives
1. The LED light is green, but the motor does not move
(1) Cause of failure: The motor in one or more directions is prohibited from operating.
Solution: Check the +INHIBIT and –INHIBIT ports.
(2) Cause of failure: The command signal is not to the driver signal.
...
|
|
How to deal with the occurrence of OL2 in Yaskawa inverter
OL2 is the inverter overload alarm, check whether it is a real overload or a false overload.
1. Test whether the output current of the inverter exceeds the rated current of the inverter, if it exceeds it, it may be the mechanical reason, if it does not exceed the inverter detection circuit is broken, and the false overload is reported.
...
|
|
Advantages of Yaskawa servo motors
1. The highest amplifier responsiveness in the industry, with a speed and frequency response of 1.6kHz
Second, the greatly enhanced vibration control function.
3. The maximum speed is increased to 6000 rpm
Fourth, the temperature rise is reduced, the efficiency is improved, and the peak torque is increased to 350%
Fifth, the first day ...
|
|
Introduction to the characteristics of Yaskawa arc welding robot
1. Coordinated control technology: control the coordinated movement of multiple robots and positioners, which can not only maintain the relative attitude of the welding gun and the workpiece to meet the requirements of the welding process, but also avoid the collision of the welding gun and the workpiece. Yaskawa Robotics is a multi-articulated manipulator or multi-degree-of-freedom robot for the industrial field. ...
|
|
How to establish an external start signal for Yaskawa Robot DX100
1. Enter the editing mode of Yaskawa robot first
2. Select "Function Effective Setting" for setting
3. Select "Allow" to start the appointment
4. Click Settings to enter "Appointment Activation (Connection)"
5. Set the input signal and output signal you need.
|
|
ATI+Yaskawa work together to achieve force-controlled weld grinding of complex workpieces
As we all know, the traditional material removal work is done manually, the cost is high, the efficiency is low, the accuracy of the parts is greatly affected by the manual, and the safety of workers is not effectively guaranteed, so what can be done to effectively solve these problems?
Today, I will take you to understand the machine ...
|
|
Yaskawa inverter - the selection of high-voltage inverter precautions
First, the disadvantages
Choosing too high a voltage level results in too high an investment and a long payback period. With the increase of the voltage level, the insulation of the motor must be improved, so that the price of the motor increases. The increase of voltage level increases the number of series connections of power semiconductor devices in the inverter, and the cost rises.
...
|
|
What could be the cause of the CF failure of Yaskawa inverter?
The fault code is CF refers to Control Failure, which reaches the torque limit for more than 3 seconds in the deceleration stop (no PG vector control mode)
Possible reasons are:
The motor parameters are not set correctly
The set value of the torque limit is too small
The load inertia is relatively ...
|
|
Yaskawa MOTOMAN servo drive fault repair case summary (3-4)
3. When the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read;
Cause of failure: The current monitoring output is not isolated from the AC power supply (transformer).
Solution: It can be detected and observed with a DC voltmeter.
4、LE ...
|
|
Yaskawa servo drive alarm 810 reset method
1. Check the reason for alarm 810: Alarm 810 is caused by the temperature inside the controller is too high, which may be caused by the heat inside the controller is too high or the power supply voltage is unstable.
2. Check the heat dissipation of the controller: check whether the radiator of the controller is blocked, ...
|
|
Yaskawa inverter fault code description and corresponding fault causes
When the Yaskawa inverter fails, the operator will display the fault content, cut off the output, and the motor will decelerate and stop freely.
The following is a description of the fault alarm code of Yaskawa inverter and the corresponding fault reason, which is for reference only.
OC Overcurrent ...
|
|
Yaskawa inverter - maintenance method of low-voltage inverter
1. Countermeasures to the overheating problem of inverter
1. For places where the operating environment temperature of the inverter is high, it is recommended to reduce the temperature of the inverter and strengthen cooling and ventilation;
2. Increase the frequency of regular maintenance of inverter fans, air ducts, etc., so as to improve the operating environment of the inverter, so that the inverter ...
|
|
Yaskawa inverter reports Uv1 fault code solution
Yaskawa inverter Uv1 fault name: main circuit undervoltage
If the operation command is not entered (the inverter is stopping), the following conditions occur.
1. The DC voltage of the main circuit is lower than the set value of L2-05 (the detection value of the undervoltage (UV) of the main circuit).
2. 200V class: about 190V ( ...
|
|
Yaskawa robot maintenance and regular inspection
For the maintenance of Yaskawa robots, maintenance should be carried out before and after each use, check whether there is damage to the outside of the robot, and check whether the robot movement is abnormal. Then be sure to check the battery frequently, and if you find that the battery is not working, you should replace it as soon as possible. The gearbox should be checked frequently to see if there is ...
|
|
Analysis of common alarm codes for Yaskawa robot servo drive maintenance
1. A.00 Absolute value data error: the absolute value data cannot be accepted or the accepted absolute value data is abnormal.
2. A.02 Parameter Destruction: The result of the "sum number check" of the user constant is abnormal.
3. A.04 User constant setting error: the set "user constant" exceeds the set ...
|
|
Fault causes and solutions of Yaskawa servo alarm A840/A84
1. Yaskawa servo alarm A840 (A84) is: encoder data error alarm.
A.84 Common causes of alarm are:
1. Excessive mechanical vibration
2. High-frequency noise in the application environment
3. Servo motor inlet water inlet oil, dust, etc
4. The driver is faulty
...
|
|
Yaskawa Robotics - Introduction to the characteristics of robot dresspacks
1. Long service life: high-quality dresspack effectively prolongs the service life of the equipment due to the optimization of the sheath material and the expansion device of the dresspack;
2. Easy to replace: In the event of an emergency with internal pipeline damage, the dresspack can be easily replaced without damaging the original sheath and cable joints.
|
|
Common faults and solutions of Yaskawa inverter
(1) Overcurrent, display character: OC. The reason for tripping is the short circuit of UVW at the output end, the load is too large, the acceleration/deceleration time is set incorrectly or the torque is unreasonable, resulting in overcurrent or overheating of the main circuit module. Check whether there is a short circuit in the motor junction box, whether the motor winding is to the ground, phase to phase ...
|
|
Yaskawa inverter - introduction to the classification of high-voltage inverter
Current type high-voltage frequency converter
It is named because the inductive element is used in the DC link of the inverter, and its advantage is that it has the ability to operate in four quadrants, and it is easy to realize the braking function of the motor. The disadvantage is that the inverter bridge needs to be forced commutation, the device structure is complex, and the adjustment is more difficult.
|
|
Yaskawa inverter model introduction
Today I would like to introduce to you what models are available in the E1000 and V1000 series:
E1000 fan pump type
1、EB4A0058
2、EB4A0002
3、EB4A0005
4、EB4A007
5、EB4A0011
6、EB4A0004
V1000 Series ...
|