Types and applications of Yaskawa's high-temperature resistant robot protective clothing
Yaskawa robot is a kind of industrial robot, which can be applied to various automated production lines according to its specifications and models, and the high-temperature work workshop is a major field where industrial robots are used more, so it needs to be protected by robot protective clothing. The following is a brief introduction to Ontor ...
|
|
Which parameter is jitter adjusted for Yaskawa servo motor?
First, the servo dispute settings are too large, and it is recommended to readjust the servo parameters manually or automatically.
Second, make sure that the initial value of the time constant of the velocity feedback filter is set to zero, and try increasing the initial value.
Thirdly, the electronic gear ratio setting is too large, it is recommended to restore ...
|
|
Yaskawa inverter - introduction to the classification of high-voltage inverter
Current type high-voltage frequency converter
It is named because the inductive element is used in the DC link of the inverter, and its advantage is that it has the ability to operate in four quadrants, and it is easy to realize the braking function of the motor. The disadvantage is that the inverter bridge needs to be forced commutation, the device structure is complex, and the adjustment is more difficult.
|
|
What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job?
What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job?
Origin Setting: Lets you set the origin and initial position of each axis.
The robot → the origin position → point display, and select the axis and robot you want to set
1. Write origin data → point ...
|
|
Yaskawa Electric restores three plants in Japan on the premise of safety
Yaskawa Electric recently announced that its soft starter processing plant in Shanghai has resumed production since February 18. So far, the three processing plants of this Japanese-funded processing and manufacturing company in China have been fully opened.
Last week, Yaskawa Electric in China processed two other ...
|
|
Precautions for the use of Yaskawa servo drives
Precautions for driver grounding in the Yaskawa servo drive manual
1. The correct shield grounding point is at the reference potential inside the circuit, which depends on the noise source and reception
Whether it is grounded at the same time, or floating.
2. Make sure that the shielding layer is in the same ...
|
|
Common types of Yaskawa drives
H1000
The new Yaskawa "H1000" heavy-duty inverter plays a stable and outstanding role in the heavy-duty industrial field!
Capacity range
200V class 0.4-110kW
400V class 0.4 - 355kW
apply
Lifting Machinery, Fluid Machinery, Metalworking Machines ...
|
|
Five major faults of servo drive and their solutions
1. Power failure: If the servo drive has no power supply or the power supply is unstable, it will cause the motor to not work properly. The solution is to check the power supply line, confirm that the power supply line is normal and stable, and if the power supply needs to be replaced, select the appropriate power supply.
2. Control signal malfunction ...
|
|
How to adjust the multi-stage speed of Yaskawa V1000 inverter?
Yaskawa Inverter A1000 User Guide 1. Description of the operator: (1). Keyboard description:
【ESC】Function:
1. Return to the previous screen;
2. Shift the bit that needs to be changed when setting the parameter number to the left;
3. If you press and hold it, you can ...
|
|
Yaskawa Robotics FAQs
Explosion-proof grade of robot for spraying use?
Compliant with TIIS, FM, ATEX, and KCs standards, please check the relevant catalogs for details.
How do I download the relevant manual for the robot?
At present, the download of the manual is not provided, and the manual comes with the robot, so please keep it properly.
...
|
|
Common faults and solutions of Yaskawa servo drives
1. When the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read;
Cause of failure: The current monitoring output is not isolated from the AC power supply (transformer).
Solution: It can be detected and observed with a DC voltmeter.
2. Motor ...
|
|
Yaskawa A1000 inverter control circuit and ground wire wiring method
Second, the wiring of the control circuit
The control circuit of the inverter can be roughly divided into two types: analog and digital.
1. The wiring of the terminal of the control circuit should use shielded wire or twisted pair wire, and it must be separately routed from the main circuit and the strong current circuit (including the 200V relay program circuit).
...
|
|
Yaskawa robot spraying process application virtual simulation operation method
Spraying is another common process application of industrial robots, second only to welding process applications, and they all belong to high-intensity, high-precision, and high-sensitivity work tasks in harsh environments.
The spraying process has extremely high requirements for the performance of the robot, of course, for the formulation of the process, ...
|
|
Yaskawa Electric – inspection work before motor operation
(1) Check and remove the dust and debris on the motor;
(2) Check whether the voltage, frequency and power supply voltage and frequency on the nameplate of the motor are consistent with the actual situation, and whether the connection method is correct.
(3) Use the insulation resistance meter to measure the phase and phase and phase of the motor winding.
|
|
Yaskawa servo motor - common faults and maintenance methods of servo drives
1. The LED light is green, but the motor does not move
(1) Cause of failure: The motor in one or more directions is prohibited from operating.
Solution: Check the +INHIBIT and –INHIBIT ports.
(2) Cause of failure: The command signal is not to the driver signal.
...
|
|
How to set the number of fault retries on Yaskawa servo
Set it in the controller's parameter settings.
1. Connect the computer and the controller to enter the parameter setting interface.
2. Find the parameters of the number of servo fault retries or FaultRetryCount.
3. Set it to the required number of retries, which is usually recommended to be set to 1— ...
|
|
Yaskawa inverter common fault--GF-ground fault
In addition to eliminating the cause of the problem of motor grounding, the most likely part of the failure is the Hall sensor, which is affected by environmental factors such as temperature and humidity, and the working point is easy to drift, resulting in GF alarm.
Produce...
|
|
There are three control modes of Yaskawa servo motor
1. Torque control mode: The torque control mode is to set the output torque of the motor shaft through the input of the external analog quantity or the assignment of the direct address, which is manifested as 10V corresponding to 5Nm, when the external analog quantity is set to 5V, the output of the motor shaft is 2.5Nm: if the electric ...
|
|
Yaskawa EPX2050 customization of robotic spraying protective clothing
Yaskawa EPX2050 robots are often used in the automotive and other industrial painting fields to complete a variety of spraying operations, but long-term operations require the use of robot protective clothing to protect them. The following is a brief introduction to how Yaskawa EPX2050 spraying protective clothing is customized.
Yaskawa EPX205 ...
|
|
How to deal with Yaskawa servo alarm 840?
1. Encoder malfunction. When the power is turned on again and this alarm still occurs, it is possible that the servo motor is faulty, and the servo motor is replaced;
2. Encoder malfunction due to noise and other interference. Correct handling of the wiring around the encoder (separating the encoder cable from the servo motor ...
|