BD series laser displacement sensor can measure the thickness, width, horizontal difference, parallax, twist and flatness of the target object by detecting the displacement.
Regardless of the color or data of the policy, the sensor can provide accurate and stable measurement results. The sensor head and amplifier unit are detachable for easy protection, and up to 8 sensor amplifier units can be interconnected to avoid disturbing each other.
Key features:
• Detachable sensor head/amplifier unit for easy protection
• Maximum resolution: 1μm (varies by type)
• Reliable detection, regardless of the color or material of the object to be inspected
• Interconnect up to 8 sensor amplifier units:
Anti-interference function and automatic channel sorting
• Supports various accounting functions (addition, subtraction, uniformity)
• Multiple filter functions for stable measurement (uniform movement, differential, median)
• Automatic sensitivity adjustment (1 point, 2 points education)
• DIN rails, wall fixtures (with wall fixture brackets)
• Sensor head: IP67 protection
|
More on that
|
Introduction to non-contact level sensors
Capacitive level sensors, ultrasonic level sensors, and discrete photoelectric level sensors. The common development of these three non-touch liquid level sensors is that they are not affected by the color, corrosiveness, pressure, density, etc. of the liquid, because these sensor skills cannot directly lead to the development of liquid ...
|
|
Autonics Solid State Relay SSR adds SR(H)2/3 three-phase
Autonics Solid State Relay SSR adds SR(H)2/3 three-phase solid state relay to its family of relays
Autonex proudly introduces you to the new formation of solid state relays, three-phase solid state relays. Compact design, flexible devices, easy ...
|
|
The difference between sensitivity, resolution, and accuracy of a sensor
sensitivity
Concept: It refers to the ratio of the change of output △y to the change of input △x in the case of steady-state operation of the sensor, that is, the ratio of the dimension of output and input.
Sensor sensitivity is the slope of the output-input characteristic curve. If the output and input of the sensor ...
|
|
Precautions for the use of through-beam photoelectric sensors - Autonex
1. Avoid strong light sources
Photoelectric sensors can generally operate stably when the ambient illumination is high. However, avoid facing the optical axis of the sensor with strong light sources such as sunlight and incandescent lamps. When the angle of the optical axis of the sensor (light receiver) and the strong light source cannot be changed, the sensor can be surrounded by ...
|
|
Pressure Sensor Fault Detection – Ottonix
First, the first component is blocked or the form of the device is wrong, and the pressure point is unreasonable, so we often emphasize that the device must be the correct device, once it is installed wrongly, or it is not well installed, it will bury endless hidden dangers for the back. What are the primary components? Orifice plates, remote transmission measuring joints, etc.
|
|
How to determine if the sensor is damaged - Autonix
1. Measure resistance (surface power-off)
(1) First use a multimeter to measure the input and output resistance of the load cell, and then compare it with the clarification. If there is a big difference, it will be broken. First, use a multimeter to measure the input and output resistance of the load cell, and then carry out the ...
|
|
Strain characteristics of pressure sensors
When measuring the strain of an element, the strain gauge can be directly glued to the component, but if you want to measure the force, pressure, acceleration and other signals, these physical quantities must first be converted into strain, and then measured with a strain gage, and the conversion process is more than when measuring directly. The first step in completing this transformation process ...
|
|
Precautions for Temperature Sensor Installation and Use – Ottonix
1. Errors in improper introduction of devices
In other words, the thermocouple should not be installed too close to the door and the heating place, and the penetration depth should be at least 8-10 times the diameter of the maintenance tube; Maintenance of thermocouples ...
|
|
Autotonix torque transducer selection
1. Selection of reliability
The potential of a sensor to persist in its properties over a period of time is called reliability. In addition to its own structure, the key factor affecting the long-term reliability of the controller is the use of harsh environments.
Harsh environments symmetrical heavy-duty sensors may lead to ...
|
|
Strengths of Autonex photoelectric sensors
1. Long detection interval. By retaining an inspection interval of more than 10 m in the through-beam model, other inspection methods can be accomplished.
2. Less detection of objects. Because the detection of shading and reflection caused by the object is the detection principle, it is not like the proximity sensor to limit the detection of the object to the metal ...
|
|
Autonicus Safety Touchless Door Switches SFN Series
The SFN series of safety non-touch door switches reliably monitors the opening and closing of dedicated actuator doors by means of magnetic detection. This product can be connected to up to 30 units through a dedicated controller, and it can be used vertically and horizontally according to the installation environment, which improves the ease of use.
...
|
|
Autotonicus photoelectric switch measurement method
1. Measurement of action distance; When the action piece is close to the sensing surface close to the switch from the front, the distance close to the switch action is the action distance close to the switch, and the measured data should be within the parameters of the product.
2. Measurement of release distance
|
|
Installation steps for dynamic torque transducers – Autonex
Dynamic torque transducers can be used in the manufacture of viscometers, electric (pneumatic, hydraulic) torque wrenches, which have the advantages of high precision, fast frequency response, good reliability and long life.
Installation process:
1. According to the connection form of the shaft and the length of the dynamic torque sensor, determine the original ...
|
|
Autonex PSK series 2-segment display pressure sensor
The PSK1 series is a two-stage display pressure sensor that displays the current value (PV) and the set value (SV) together. It not only shows the setting status, but also provides a power-saving form and a fine-tuning function to improve the user's convenience.
PSK1 Key Features:
Additional pressure scale (composite pressure ...
|
|
Key points of visual inspection of electric motors - Ottonix
Key 1: Whether the speed of the motor is normal, whether there is speed jitter and stalled rotation (you can check it with a tachometer).
The key is whether the anchor bolts of the motor are loose, whether the root is defective, and whether there are debris around.
The key is three, whether the housing and coupling of the motor are defective, ...
|
|
Load cell quality selection – Autonex
1. Observe whether the outside of the load cell is deformed or cracked. If there is any damage, please contact the manufacturer immediately.
2. Find the connection end of the sensor in the weighing controller, and measure the connection circuit of the sensor. The general excitation voltage (between EXC+ and EXC-) is 5-10V, and the output ...
|
|
Introduction to Digital Fiber Optic Sensors
Digital fiber optic sensors convert measured objects into measurable optical signal sensors. Its working principle is to send the incident beam of the light source to the modulator through the optical fiber, and interact with the internal and external measurement parameters of the modulator to form a dimmable signal. Digital Fiber Optic Sensors ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|
|
Autonex launches a new product - multi-channel pressure sensor PSM series
The multi-channel pressure indicators of the PSM series can display the measured values of up to 4 or 8 channels of analogue pressure sensors. When used in conjunction with our PSS series pressure sensors, the sensor type, pressure type and range can be automatically recognized without additional settings. Users can also easily ...
|
|
Introduction to Autonix pressure sensor technology
1. Capacitive Capacitive pressure sensors are usually cleaned by a large number of OEM professional applications, testing the capacitance change between two surfaces, so that these sensors can sense the extreme pressure and vacuum level. In our typical sensor setup, the compact outer gram contains two metal exteriors, ...
|
|