1. The acceleration moment is too short.
Theoretically, the longer the acceleration time, the stronger the load lifting capacity. If the acceleration time is set too short, some VFDs will show an overcurrent or overload, overtemperature alarm, while others will not, and will only be stuck in a certain frequency band.
2.The V/F ratio is too large
Some of these VFDs are also called torque lifting. If this parameter is set too large, it may not be able to start properly. If the cuts are appropriate, the problem is solved.
3. Vector manipulation parameters do not match.
In the vector control mode, the internal resistance, inductance and other parameters of the motor need to be accurately measured, and the vector parameters of the VFD need to be matched. After a period of operation, the motor parameters will overheat, causing errors. At this time, the current will be too large to start the motor normally, and the frequency may be stuck at a certain point. Optimizing parameters de novo solves the problem.
4. The maximum frequency and maximum frequency are set too low.
Generally, these two parameters are set to the maximum value, but there are some careless electricians who change these two parameters, so it will also lead to the inability to upcycle.
5. Some special occasions require parameter pairing.
In some cases, the minimum frequency should not be set too low. For example, in a constant pressure water supply system, when the minimum frequency is set to 0Hz, when the pump pressure is low, when the starting frequency of VFD and VFD is exceeded, the start is accelerated, and the pressure cannot be increased. The frequency of the VFD cannot progress to 50Hz, which is about 38Hz. After adjusting the PID repeatedly, the frequency cannot be improved. As long as the minimum frequency of VFD is set at about 15-20HZ, we can be satisfied with the acceleration of VFD and maintain a certain pressure of the pump. Although the pressure meets the constant pressure requirements, the VFD cannot be completely stopped without water, and the minimum frequency speed is always maintained.
This is due to: in the constant pressure water supply system, the minimum frequency of VFD cannot be set to 0HZ, generally at least about 20HZ, which is determined by the flow rate and head of the pump.
The workaround is to set the frequency of sleeping. When the frequency of the pump (e.g. 28HZ) runs for a few minutes, the pump will go to sleep. When the pressure drops to 0.2-0.4MP lower than the set pressure, the pump will start. Another way is to set up a punctual water supply, which is supplied in several time slots. Typically, a constant pressure water supply manipulator has the above features.
6. Hardware issues
A similar situation may occur if the VFD's transformer (Hall) is problematic and cannot properly measure the correct current. In addition, this can also be the case when one of the measuring components on the motherboard is aging. These are all common problems encountered when correcting VFDs.
|
More on that
|
Reynolds drives RNB1000 series fault code resolution
Reynolds inverter fault codes:
E.bC
Reynolds inverter fault phenomenon/type:
Brake unit failure
Reynolds inverter failure may be caused:
1. Brake line failure or brake ...
|
|
The inverter cannot adjust the frequency solution - Reynolds
In the course of inverter repairs, if there is no significant damage to the hardware and the maximum torque of the VFD is usually less than the torque of the load increase. It means that the load capacity of the frequency conversion speed control equipment has decreased significantly. So how do you deal with this?
...
|
|
Advantages of the inverter vector control system - Reynolds
Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed.
At low frequencies ...
|
|
Progressive method of robustness of automatic control cabinets – Reynolds
1. Appropriate working environment
1. The ambient temperature is suitable
All manufacturers have certain rules for active temperature control cabinets. The PLC promises that the ambient temperature is usually about 0 to 55 ° C, so during the equipment process, this heating element is not placed in the PLC; The PLC should have adequate ventilation and ...
|
|
Safety precautions for low-voltage soft lift - Reynolds
Precautions for low-voltage soft starters
For cooling purposes, the soft starter must be installed in a straight direction.
In order to ensure excellent heat dissipation, there should be room for the soft starter device.
Main circuit selection ...
|
|
The lightning protection method of Reynolds inverter
The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important.
Today's inverter products are generally equipped with lightning ...
|
|
Inverter acceleration and deceleration mode selection
The selection of the acceleration form and deceleration form of the inverter is also called the selection of acceleration and deceleration curves. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows.
1. Linear form
The form makes the inverter ...
|
|
Frequency converter maintenance and interference removal – Reynolds frequency converters
Working environment
In the actual application of inverters, most people install inverters directly in industrial sites in order to reduce costs. The job site generally has the problems of large dust, high temperature and high humidity, and in some occupations, there are also metal dust, corrosive gases and so on. There must be ...
|
|
Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system
From September 23rd to September 25th, 2020, the 2020 China International Paper Technology Exhibition was held in Hall D1 of Suzhou International Expo Center.
|
|
Methods and steps of frequency conversion speed regulation - Reynolds
Frequency conversion speed regulation is to change the power supply frequency through the frequency converter, and then adjust the motor speed to improve the operation efficiency of the electric drive system. Depending on the current, VFDs can be divided into AC-DC-AC type and AC-AC type. At present, the most widely used in China is the AC-DC-AC type.
...
|
|
Reynolds inverter manual
Reynolds inverter brochure (partial)
Before installing
When unpacking, it is found that the machine has water or left water traces, indicating that the inverter has been flooded, so please do not install and use it.
When unpacking, it is found that the machine is damaged and deformed or the parts are missing, please do not install and use it, otherwise there will be fault expansion and personnel ...
|
|
The solution to the low or high output of the differential pressure transmitter – ifm
When the differential pressure flowmeter (V-cone flowmeter) is used in the field, it often encounters such and such problems, but the reason for it is investigated, as long as it is installed correctly, the primary problem is on the secondary surface differential pressure transmitter, and the following is the first to introduce these problems to us ...
|
|
The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy
Shanghai Reynolds Technology Co., Ltd. is an enterprise specializing in the design and production of high and low voltage soft starters, high and low voltage variable frequency speed regulation, intelligent electrical, new energy electrical and high and low voltage power transmission and transformation equipment, which are widely used in electric power, metallurgy, petroleum and petrochemical, military, mining, chemical industry, ...
|
|
Features of the unit tandem inverter - Reynolds
(1) The multi-pronged PWM control method is selected, and the output voltage waveform is close to the sine wave.
(2) The rectifier circuit is multiplied, the number of pulses is as high as 36, the power factor is high, and the input harmonic is small.
(3) Modular design, compact structure ...
|
|
There will be problems with the inverter left for a long time - Reynolds
Most inverter brand products can rely on the heat generation of internal electrical components to remove moisture during normal use. If you don't have to do it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...
|
|
Reynolds frequency converters are remotely controlled for wiring
1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation;
2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency)
3. ...
|
|
Reynolds frequency converters RNB1000 series E.ITE fault codes
Reynolds inverter problem code:
E.ITE
Reynolds inverter problem phenomenon/type:
Problems with the current sensing circuit
Possible causes of Reynolds inverter problems:
1. Poor contact of the control board connector
2. The auxiliary power supply is damaged
3. Hall ...
|
|
The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter
In order to measure stable harmonics, it is necessary to meet the following two conditions:
At the top of the list, the signal is a stable periodic signal.
Second, it is necessary to perform harmonic analysis according to the integer multiple of the period of the stable periodic signal.
...
|
|
Key points for the selection of AC contactors - Reynolds
1. Select varieties according to the above series according to the purpose and requirements of use
Note that the main circuit load type is strictly differentiated, whether it is DC or communication.
The communication contactor is different from the DC contactor, and is only suitable for DC-1 to DC-5 loads when used for DC loads.
|
|
Germany core control appeared at the China International Industry Fair
It is human beings who have always been committed to making human-computer interaction safer, easier to use, and more efficient, which has made collaborative robots gradually become the main stream of shopping malls.
It is precisely because of the vigorous development of the collaborative robot industry that Synapticon Gmb ...
|
|