Reynolds frequency converters are remotely controlled for wiring

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation;

2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency)

  ​                      Reynolds frequency converters are remotely controlled for wiring

3. Other DO (switching output) is used to transmit signals such as operation and fault, and AO (analog output) is used to transmit real-time data such as current, speed, torque, etc.

All functions of the inverter need to be set in the parameters, not all functions can be completed together, and the details depend on the detailed requirements.

More on that
Elimination of inverter harmonics method – Reynolds Elimination of inverter harmonics method – Reynolds

a. Add the internal impedance of the power supply of the inverterIn general, the internal impedance of the power supply equipment can play a role in buffering the reactive power of the DC filter capacitor of the inverter. This internal impedance is the short-circuit impedance of the transformer. When the power supply capacity is smaller than the inverter capacity, the internal impedance value is relatively large.

Inverter: The right inverter to use - Reynolds Inverter: The right inverter to use - Reynolds

Low pressure issues The VFD reports a low voltage issue when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac). The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system actively adjusts the speed of the pump and the number of pumps according to the set pressure, so that the equipment can run in ...

Precautions for the coordination of PLC and inverter - Reynolds Precautions for the coordination of PLC and inverter - Reynolds

Under the current production conditions, when the inverter is used to form an automatic control system for control, in many cases, it is necessary to choose PLC and inverter to match the use, such as bearing cleaning, packaging paper printing, PCB board production, etc. PLC ...

PLC and inverter communication mode PLC and inverter communication mode

1. The switching signal of PLC controls the inverter The PLC can control the start, stop and reset of the inverter through the program; It can also control different combinations of high-speed, medium-speed and low-speed terminals of the inverter to achieve multi-stage speed operation. However, because it is controlled by switching ...

Reynolds drives use the most energy-efficient method Reynolds drives use the most energy-efficient method

As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the additional power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical. But the conditions are: At the top of the list, great success ...

Inverter replacement component requirements - Reynolds Inverter replacement component requirements - Reynolds

1) Find out the basic parameters and appearance of the equipment that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics and saturation voltage of the IGBT (including IPM) device, etc.

The inverter uses a power-saving method – Reynolds The inverter uses a power-saving method – Reynolds

As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the rated power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical. However, the conditions are: First, high power and ...

Precautions for multiple motors in one inverter - Reynolds Precautions for multiple motors in one inverter - Reynolds

Equipment selection 1. Inverter selection. When it comes to sizing, the first thing to consider is the operating conditions – whether one or more motors should be started or stopped at any time during the operation of the inverter. If the motor does not need to be started at any time during the operation of the inverter, it may only be stopped or ...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

"RNB6000 frequency conversion governor" was included in the National Torch Program "RNB6000 frequency conversion governor" was included in the National Torch Program

Recently, in the "2012 National Torch Program Project" issued by the Ministry of Science and Technology of the People's Republic of China, the "RNB6000 Frequency Conversion Governor" independently developed by Reynolds was included in the "2012 National Torch Program Project" with its domestic leading skills and efficient energy-saving conversion power.

Protection feature of overcurrent trip - Renol Protection feature of overcurrent trip - Renol

1. Maintenance objectives of overcurrent In the frequency conversion speed regulation system, there are two devices: the frequency converter and the motor. The degree of tolerance to overcurrent is not the same. The planners of the production machinery decide on the capacity of the motor based on the principle of heat. That is, as long as the electricity ...

The Reynolds SVG series was successfully completed The Reynolds SVG series was successfully completed

More than 40 sets of RNSVG series low-voltage power generator sets and RNZB series high-voltage reactive power automatic compensation devices designed and produced by Reynolds have been successfully completed and will be delivered in the near future. This product is owned by Shanghai Reynolds ...

Introduction to the appearance of Reynolds inverter Introduction to the appearance of Reynolds inverter

Bypass cabinet: The cabinet is equipped with high-voltage inlet and outlet isolation switches QS1 and QS2, as shown in Figure 2. Among them, QS1 is a single-pole single-throw variable frequency incoming knife switch, and QS2 is a single-pole double-throw power frequency and variable frequency outgoing knife switch. The bypass cabinet is a high-voltage environment, please observe the live display and electromagnetic lock status to ensure that the ...

Inverter control method - Reynolds Inverter control method - Reynolds

The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the operating frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sinusoidal Pulse Width Modulation (SPWM) Manipulation MethodIts Characteristics ...

Reynolds assisted Sinopec Weirong shale gas project Reynolds assisted Sinopec Weirong shale gas project

With the rapid development of China's national economy, the supply and demand situation of oil and gas resources is becoming increasingly severe, and the import of oil and gas is increasing year by year, so it is urgent to expand the field of domestic oil and gas exploration and development. Strengthening the exploration and development of shale gas resources can make up for the lack of conventional oil and gas resources and promote the sustainability of the oil and gas industry.

Indicator of Reynolds inverter cabinet wiring Indicator of Reynolds inverter cabinet wiring

Voltage level: The voltage level should match the voltage level of the power supply and motor to ensure electrical safety and normal operation of the equipment. Current level: The current level should match the rated current of the motor to ensure electrical safety and normal operation of the equipment. Cable Specification: Cable ...

Reynolds high-speed permanent magnet synchronous motor dedicated driver Reynolds high-speed permanent magnet synchronous motor dedicated driver

The state proposes to "peak carbon emissions" by 2030 and complete "carbon neutrality" by 2060. Carbon neutrality is to try to reduce carbon dioxide emissions, and eventually achieve net zero emissions, that is, to make carbon dioxide emissions even offset. However, due to economic development, CO2 emissions are stable ...

Use the right power for the inverter – Reynolds Use the right power for the inverter – Reynolds

Low pressure issues The VFD reports a low voltage glitch when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac). The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...

Introducing the Reynolds JJR8000 series of intelligent soft starters Introducing the Reynolds JJR8000 series of intelligent soft starters

JJR8000 series of intelligent motor soft starter is the use of power electronics skills, microprocessor skills and modern control theory skills to produce today's international first-class starting equipment, the product can constrain the starting voltage of the asynchronous motor when starting, can be used in fans, water...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top