Precautions for low-voltage soft starters
For cooling purposes, the soft starter must be installed in a straight direction.
In order to ensure excellent heat dissipation, there should be room for the soft starter device.
The main circuit is selected to be progressively lowered, and the conductor should ensure that the current carrying capacity is satisfied.
High Voltage Safety Precautions
The information presented in the High Voltage Product Manual should be used in conjunction with the safety procedures of your workplace.
It is everyone's responsibility to ensure that they operate in a safe manner and that they comply with any local laws or site regulations.
Ensure that the work area is risk-free.
Evaluate the risks and create a list to comment on with the relevant personnel.
Know how to quickly contact urgent help.
The installation and protection operation should be strictly in accordance with the high-voltage product manual, national standards and industry practices, otherwise the manufacturer will not be responsible for all adverse consequences caused by the operation of the corresponding guidance standards.
Before protecting the soft starter or motor, it is necessary to disconnect all power inputs.
After installation, it should be carefully inspected to verify that no parts (such as screws, washers, etc.) have fallen into the live equipment.
Precautions for high-voltage devices
It is necessary to carry out the operation of the plant under the supervision of a qualified person.
Both compressed air and electricity are very risky. Before any work is done on the compressor, ensure that the power supply is blocked and the pressure is unloaded.
It was necessary for the installation of this heat recovery system to comply with recognized local health and safety standards as well as water and plumbing standards. Any connections/components other than the compressor that are used to control the flow, temperature and pressure of the inlet or outlet water of the heat recovery system are within the responsibility of the unit or the customer.
This product should be installed in a place where there are no obstructions or hazards to operate and protect, and clear indication signs can be seen at all times.
If it is necessary for the product to be placed on a channel at a high place, it is required not to disturb normal operation or prevent access. Channels and stairs should be grid or slab structures, with safety guardrails on all open surfaces.
|
More on that
|
Reynolds inverter power selection
The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points:
VFD ...
|
|
Precautions for installation of Reynolds low-voltage inverters
One. Safety Precautions
1. First of all, it is necessary to have certain electrical professional knowledge, and understand the job site, understand the equipment status, and have certain electrical operation technology.
2. Determine the voltage level of the equipment (such as low-voltage AC380V) and whether it is low-voltage ...
|
|
Reynolds inverter E.oC3 constant speed operation overcurrent fault solution
Reynolds inverter RNB1000 series E.oC3 constant speed operation overcurrent fault solution
Reynolds inverter fault codes:
E.oC3
Reynolds inverter fault phenomenon/type:
Constant speed operation overcurrent
Possible causes of Reynolds inverter failure:
...
|
|
Reynolds servo motor selection steps
According to the requirements of the operating conditions, the appropriate load inertia accounting formula is selected to calculate the load inertia of the organization.
According to the load inertia and servo motor inertia, the appropriate servo motor standard is selected.
Combined with the inertia and load inertia of the primary servo motor, the acceleration torque and deceleration are calculated.
|
|
Frequency conversion cabinet external conduit wiring method - Reynolds
When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods:
1. Kim ...
|
|
Precautions for the use of frequency converters - Reynolds
In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter:
1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...
|
|
Soft-start starting method – Reynolds
1) Ramp boost soft start. This starting method is simple, does not have current closed-loop control, and only adjusts the conduction angle of the thyristor to make it add a certain function with time. The disadvantage is that because there is no current limit, in the process of motor starting, sometimes a large impulse current is generated.
|
|
Applicable mode of inverter maintenance - Reynolds inverter
CNC cutting machine
1. Gradual reduction method
The so-called gradual reduction method is to narrow the scope of shortcomings step by step by elaborating the shortcomings and judging the measurement parameters.
|
|
Features of Reynolds high-voltage frequency converters
RNVH-A series high-voltage inverter adopts multi-unit series multi-level technology, which is attributed to high-high voltage source inverter, which can directly input 6KV/10KV and direct 6KV/10KV output. Taking the 6KV series as an example, each phase is connected in series by 5 power units, and each power unit is isolated by the input transformer.
|
|
The basic principle of vector control – Reynolds frequency converters
The fundamental principle of vector control is to control the excitation current and torque current of the asynchronous motor according to the principle of magnetic field orientation through the measurement and control of the stator current vector of the asynchronous motor, and then to achieve the purpose of controlling the torque of the asynchronous motor. Specifically, it is to ...
|
|
Water pump inverter pressure adjustment method - Reynolds
Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...
|
|
Fault analysis of short circuit of inverter motor – Reynolds
According to the different degrees of short circuit, the inverter can display the short circuit of the SCF1 motor; SCF2 has an impedance short circuit; SCF3 is short-circuited to ground.
Causes of the problem: insulation problems with the cable from the motor or inverter to the motor; current transformer fault; ...
|
|
Reynolds drive safety rules and warnings
The high-voltage inverter has been designed with the safety of the user in mind. However, due to the energy storage capacitor installed inside the power unit of the inverter, it may still carry a high voltage after disconnecting the power supply, and some parts generate a lot of heat, so contact is prohibited. When working on or near the inverter, please ...
|
|
Control method of Reynolds inverter
The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system.
Typical wiring method for the main circuit of a Reynolds frequency converter
...
|
|
Structural characteristics of Reynolds RHY series inverter governor
1. Technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection;
2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system actively adjusts the speed of the pump and the number of pumps according to the set pressure, so that the equipment can run in ...
|
|
The abnormal installation of the inverter in the power frequency motor leads to hazards
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur:
...
|
|
Reynolds assisted Sinopec Weirong shale gas project
With the rapid development of China's national economy, the supply and demand situation of oil and gas resources is becoming increasingly severe, and the import of oil and gas is increasing year by year, so it is urgent to expand the field of domestic oil and gas exploration and development. Strengthening the exploration and development of shale gas resources can make up for the lack of conventional oil and gas resources and promote the sustainability of the oil and gas industry.
|
|
Reynolds inverter overhaul process
1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...
|
|
The cause of the heating of the inverter of the special machine
1. Problems of the inverter and the motor itself;
After the motor has been used for a long time, it cannot be ruled out that the insulation function is not good, or the bearing is stuck, and it may show a large current and heat. The coupling between the motor and the load may also be worn, or the motor is unbalanced in three phases, and the fixtures of the motor are loose.
|
|
General Purpose Inverter Repair Inspection – Reynolds
The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...
|
|