Reynolds drives RNB1000 series fault code resolution

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

Reynolds inverter fault codes:

                                 Reynolds drives RNB1000 series fault code resolution

  E.bC

Reynolds inverter fault phenomenon/type:

Brake unit failure
  ​
Reynolds inverter failure may be caused:

1. Brake line failure or brake pipe damage

2. The resistance value of the external braking resistance is small

Reynolds drive solutions:

1. Check the brake unit and replace the brake tube with a new one

2. Increase the braking resistance

3. Find a manufacturer for service
More on that
Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

The solution to the low or high output of the differential pressure transmitter – ifm The solution to the low or high output of the differential pressure transmitter – ifm

When the differential pressure flowmeter (V-cone flowmeter) is used in the field, it often encounters such and such problems, but the reason for it is investigated, as long as it is installed correctly, the primary problem is on the secondary surface differential pressure transmitter, and the following is the first to introduce these problems to us ...

Inverter breakdown factor – Reynolds Inverter breakdown factor – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the additional voltage, which is reflected in the DC voltage of the inverter DC bus. Overvoltage alarm generally appears when the machine is shut down, and its main ...

The inverter cannot adjust the frequency solution - Reynolds The inverter cannot adjust the frequency solution - Reynolds

1. The acceleration moment is too short. Theoretically, the longer the acceleration time, the stronger the load lifting capacity. If the acceleration time is set too short, some VFDs will show an overcurrent or overload, overtemperature alarm, while others will not, and will only be stuck in a certain frequency band. 2.The V/F ratio is too large Some of this ...

Indicator of Reynolds inverter cabinet wiring Indicator of Reynolds inverter cabinet wiring

Voltage level: The voltage level should match the voltage level of the power supply and motor to ensure electrical safety and normal operation of the equipment. Current level: The current level should match the rated current of the motor to ensure electrical safety and normal operation of the equipment. Cable Specification: Cable ...

Frequency characteristics of Reynolds frequency converters Frequency characteristics of Reynolds frequency converters

a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency is different according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter. ...

The basic principle of vector control – Reynolds frequency converters The basic principle of vector control – Reynolds frequency converters

The fundamental principle of vector control is to control the excitation current and torque current of the asynchronous motor according to the principle of magnetic field orientation through the measurement and control of the stator current vector of the asynchronous motor, and then to achieve the purpose of controlling the torque of the asynchronous motor. Specifically, it is to ...

Reynolds frequency converters RNB1000 series E.ITE fault codes Reynolds frequency converters RNB1000 series E.ITE fault codes

Reynolds inverter problem code: E.ITE Reynolds inverter problem phenomenon/type: Problems with the current sensing circuit Possible causes of Reynolds inverter problems: 1. Poor contact of the control board connector 2. The auxiliary power supply is damaged 3. Hall ...

Reynolds permanent magnet synchronous motor solutions Reynolds permanent magnet synchronous motor solutions

The permanent magnet synchronous motor has high-efficiency motor drive performance, which can complete high-speed, high-precision, high-stability, fast-responding, high-efficiency and energy-saving motion control. Reynolds drives provide a vector control technology solution for permanent magnet synchronous motors. ...

Reynolds product range models Reynolds product range models

JJR1000系列:   JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1 ...

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

Frequency converter soft troubleshooting – Reynolds Frequency converter soft troubleshooting – Reynolds

Undervoltage is also a problem that we often encounter in application. Mainly because the voltage of the main circuit is too low (220V series is lower than 200V, 380V series is lower than 400V), the main reason: a certain way of the rectifier bridge is damaged or there is abnormal operation in the three ways of the thyristor, which may lead to the appearance of undervoltage problems, ...

The role of frequency conversion technology in work equipment - Reynolds The role of frequency conversion technology in work equipment - Reynolds

Because inverters are widely used, there are many differences in the corresponding types and specifications. We are broadly divided into two categories: voltage and current. The current type of inverter products is characterized by the use of a large inductor as the energy storage link in the middle DC link, and the reactive power will be buffered by this inductor. ...

Misunderstanding of inverter selection - Reynolds Misunderstanding of inverter selection - Reynolds

1. In order to save power, the inverter is selected Many manufacturers and salesmen praise how high the power-saving rate of the inverter is, and the user also believes that it is true, and the inverter is selected at a high cost simply in order to save electricity, but the results are greatly disappointed. Whether the inverter can save power after using it is determined by the load driven by it.

Precautions for Wiring Reynolds Inverters Precautions for Wiring Reynolds Inverters

1. The inverter itself has a strong electromagnetic disturbance, which will disturb the work of some equipment, so we can add a cable sleeve to the output cable of the inverter. 2. The control line in the inverter or control cabinet is at least 100mm away from the power cable, etc. ...

Key points for the selection of Reynolds servo motors Key points for the selection of Reynolds servo motors

Each type of servo motor has additional torque, maximum torque and servo motor inertia and other parameters in the standard items, each parameter and load torque and load inertia must have a relevant connection, the output torque of the servo motor should meet the requirements of the movement conditions of the load organization, such as the speed of the acceleration ...

Safety standards for AC drives – Reynolds Safety standards for AC drives – Reynolds

International electrical safety standards: The requirements are in line with international electrical safety standards, such as CE standards in Europe and UL specifications in United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc. ...

General Purpose Inverter Repair Inspection – Reynolds General Purpose Inverter Repair Inspection – Reynolds

The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...

Motor overload fault solution - Reynolds Motor overload fault solution - Reynolds

Causes of inverter failure: 1. The grid voltage is too low 2. The rated current of the motor is set incorrectly 3. The motor stall or load abrupt change is too large 4. Large horse-drawn trolley Inverter solutions: 1 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top