(1) The multi-pronged PWM control method is selected, and the output voltage waveform is close to the sine wave.

                                  Features of the unit tandem inverter - Reynolds

(2) The rectifier circuit is multiplied, the number of pulses is as high as 36, the power factor is high, and the input harmonic is small.

(3) Modular design, compact structure, convenient protection, enhance the interchangeability of products.

(4) Direct high-voltage output, no need for output transformer.

(5) Very low dv/dt output, no filter of any kind.

(6) The selection of optical fiber communication technology improves the anti-interference ability and reliability of the product.

(7) The power unit actively bypasses the circuit, which can realize the function of non-stop failure.

More on that
The inverter prepares the braking resistance factor – Reynolds The inverter prepares the braking resistance factor – Reynolds

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the capacitor voltage being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and avoid energy waste. However, the capacitance of the capacitor is ...

Reynolds high-speed permanent magnet synchronous motor dedicated driver Reynolds high-speed permanent magnet synchronous motor dedicated driver

The state proposes to "peak carbon emissions" by 2030 and complete "carbon neutrality" by 2060. Carbon neutrality is to try to reduce carbon dioxide emissions, and eventually achieve net zero emissions, that is, to make carbon dioxide emissions even offset. However, due to economic development, CO2 emissions are stable ...

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

Features of electronic single-phase current transmitter – Reynolds Features of electronic single-phase current transmitter – Reynolds

Single-phase current transmitter is a kind of electric power test substation developed for the power measurement of single-phase communication in motor experiments on the basis of motor experiment and testing technology research, in accordance with IEC and relevant national specifications for motor experiments. The use of advanced filtering technology, reasonable software algorithms, ...

The frequency of the frequency converter is given in a given way The frequency of the frequency converter is given in a given way

The first way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps to complete the output frequency controllability? One of the first and foremost key points is how to complete the change of the frequency signal supplied by the inverter equipment.

Reynolds JJR5000 Series Soft Starter Manual Reynolds JJR5000 Series Soft Starter Manual

Reynolds JJR5000 series all-digital intelligent communication motor soft engine adopts power electronics skills, microprocessor skills and modern control theory skills, and is a new type of engine equipment at the current level. The product can limit the starting current of the asynchronous motor when it starts, and is widely used in electric fans, ...

Precautions for installation of Reynolds low-voltage inverters Precautions for installation of Reynolds low-voltage inverters

1. Safety precautions 1. The primary requirement is to have certain electrical professional knowledge, and understand the job site, understand the equipment status, and have certain electrical operation technology. 2. Determine the electrical ...

Wiring method and principle of PLC and inverter shielded wire - Reynolds Wiring method and principle of PLC and inverter shielded wire - Reynolds

In order to avoid the interference of the control signal line between the PLC and the inverter by the space electromagnetic field, the shielding wire can be connected to the outer layer of these control signal lines to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the grounding point of the shield. Whether it's on the PLC side, or ...

Reynolds soft starter manual Reynolds soft starter manual

Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, and is a new type of starting equipment at the international advanced level. This product can effectively limit the starting current of asynchronous motor start-up, and is widely used in ...

The cause of damage to the inverter brake unit - Reynolds The cause of damage to the inverter brake unit - Reynolds

The inverter motor is equipped with a mechanical brake, is the inverter motor in the power generation condition when parking? Is the brake unit of the inverter working at the moment? What are the causes of brake unit damage? Answer: 1. The inverter motor is equipped with a mechanical brake, and when parking...

Misunderstanding of inverter control loop wiring - Reynolds Misunderstanding of inverter control loop wiring - Reynolds

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This effectively prevents the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Abnormal handling of inverter series reactor - Reynolds Abnormal handling of inverter series reactor - Reynolds

Capacitor series reactors generally adopt epoxy glass fiber multi-encapsulated parallel structure, according to the characteristics of the device site, three-phase vertical stacking, three-phase horizontal "△" and three-phase horizontal "-" type distribution. The substation in the southern area ...

Inverter maintenance power-on test instructions - Reynolds Inverter maintenance power-on test instructions - Reynolds

First, the inverter is not repaired and the power test is tested (1) Inverter repair test rectifier circuit At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T, and there are tens of ohms under normal conditions.

Introduction to soft starters and their relationship with frequency converters - Reynolds Introduction to soft starters and their relationship with frequency converters - Reynolds

When the high-power motor starts, the current is large, which will cause the grid voltage to be seriously shaken, in order to deal with this problem, the general requirements for speed regulation are not high, and the soft engine can be used to reduce the voltage and start. However, the drop in the starting current when the step-down is started will also make the starting torque drop significantly.

What inverter to choose what occasion - Reynolds What inverter to choose what occasion - Reynolds

We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter. When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a ...

The relationship between Reynolds motion control and frequency converters The relationship between Reynolds motion control and frequency converters

Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...

Operating instructions for the Reynolds control panel Operating instructions for the Reynolds control panel

1. FUN button; Press the FUN button to enter the settings menu F00; 2. Press and hold the up button or down button to scroll to the code that needs to be set; 3. Press the FUN button to confirm at this moment, and adjust the entry parameters to the required value; 4. After the adjustment is completed, press the WR storage button, and then the panel will display the ...

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

Inverter composition and various functions - Reynolds Inverter composition and various functions - Reynolds

Rectifier circuit: rectify 50HZ communication power into direct current. Frequency conversion circuit: The rectified direct current is inverted into a variable frequency communication current. Control part: control the frequency of communication electricity output by the inverter circuit. Maintenance circuit: maintenance and blockage of overcurrent and phase loss ...

Frequency converter soft troubleshooting – Reynolds Frequency converter soft troubleshooting – Reynolds

Undervoltage is also a problem that we often encounter in application. Mainly because the voltage of the main circuit is too low (220V series is lower than 200V, 380V series is lower than 400V), the main reason: a certain way of the rectifier bridge is damaged or there is abnormal operation in the three ways of the thyristor, which may lead to the appearance of undervoltage problems, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top