Shanghai Reynolds Technology Co., Ltd. is an enterprise specializing in the design and production of high and low voltage soft starters, high and low voltage variable frequency speed regulation, intelligent electrical, new energy electrical and complete sets of high and low voltage power transmission and transformation equipment, which are widely used in electric power, metallurgy, petroleum and petrochemical, military industry, mining, chemical industry, construction, building materials, light industry, pharmaceutical, municipal, textile printing and dyeing, papermaking, rubber and plastics, electrified railway and other industries.
The Reynolds exhibition takes place from May 22 to 24 at the SParma Industrial Automation Exhibition (SPSIPC) Center in Italy. The exhibition center brings together outstanding enterprises from all over the world, cutting-edge technology, and brings a visual feast to professional audiences.
Let's just say that there are friends from afar, and it is very happy! During the three-day exhibition, Renle received hundreds of interested customers, hundreds of customers interested in continuing the exchange, half of them local Italy companies. At the exhibition, what you see is that our company brings you rich functions, powerful functions, excellent performance, stable performance, can drive three-phase AC asynchronous motor or three-phase AC permanent magnet synchronous motor, in terms of controlling and adjusting the torque and speed of the three-phase asynchronous motor, low-speed and high-torque output, with good dynamic performance, super overload capacity of RNB1000 inverter, RNB2000 inverter, RNB5000 inverter, RNB6000 inverter, RNHV series high-voltage inverter.
|
More on that
|
Reynolds permanent magnet synchronous motor solutions
The permanent magnet synchronous motor has high-efficiency motor drive performance, which can complete high-speed, high-precision, high-stability, fast-responding, high-efficiency and energy-saving motion control. Reynolds drives provide a vector control technology solution for permanent magnet synchronous motors.
...
|
|
Method for measuring the quality of frequency converter modules – Reynolds
1. Test rectifier circuit:
To the P end and N end of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, the red watch rod is connected to P, and the black watch rod is separated from R, S, T, and there are tens of ohms of resistance in normal times, and it is basically balanced. Instead, connect the black watch rod to the P end, and the red watch stick will be ...
|
|
Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"
In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".
|
|
Safety standards for AC drives – Reynolds
International electrical safety standards: The requirements are in line with international electrical safety standards, such as CE standards in Europe and UL specifications in United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc.
...
|
|
Reynolds inverter E.oC3 constant speed operation overcurrent fault solution
Reynolds inverter RNB1000 series E.oC3 constant speed operation overcurrent fault solution
Reynolds inverter fault codes:
E.oC3
Reynolds inverter fault phenomenon/type:
Constant speed operation overcurrent
Possible causes of Reynolds inverter failure:
...
|
|
The role of frequency conversion technology in work equipment - Reynolds
Because inverters are widely used, there are many differences in the corresponding types and specifications. We are broadly divided into two categories: voltage and current. The current type of inverter products is characterized by the use of a large inductor as the energy storage link in the middle DC link, and the reactive power will be buffered by this inductor. ...
|
|
Advantages of frequency converters over soft start – Reynolds
(1) The starting torque is large and the power factor is high. Because the power factor of the motor is related to the working frequency, the power factor under the power frequency power supply is much lower than that under the low-frequency power supply when the motor is running at low speed. The inverter can control the motor from low frequencies and ...
|
|
Safety precautions for low-voltage soft lift - Reynolds
Precautions for low-voltage soft starters
For cooling purposes, the soft starter must be installed in a straight direction.
In order to ensure excellent heat dissipation, there should be room for the soft starter device.
Main circuit selection ...
|
|
The reason for using frequency conversion speed regulation - Reynolds
Variable frequency speed regulation can be used in most motor drag occasions, because it can provide accurate speed control, so it can easily control the rise, descent and variable speed operation of mechanical transmission. The use of frequency conversion can greatly improve the efficiency of the process (the variable speed does not depend on the mechanical part) and at the same time ...
|
|
Reynolds universal inverter start-up mode
1. Direct launch
The universal inverter insists on starting at the beginning of the time according to the set starting frequency and starting frequency, and then accelerates to a given frequency according to the selected acceleration time
Second, the speed of the tracking start
Universal inverter ...
|
|
The factor that causes the breakdown of the inverter – Reynolds
1. Overpressure leads to brake pipe breakdown.
The so-called overvoltage of the inverter refers to the fact that the inverter voltage formed due to various reasons exceeds the additional voltage, which is concentrated in the DC voltage of the inverter DC bus.
The overvoltage alarm generally appears at the time of shutdown, and its main ...
|
|
PLC and inverter communication mode
1. The switching signal of PLC controls the inverter
The PLC can control the start, stop and reset of the inverter through the program; It can also control different combinations of high-speed, medium-speed and low-speed terminals of the inverter to achieve multi-stage speed operation. However, because it is controlled by switching ...
|
|
Reynolds drive safety rules and warnings
The high-voltage inverter has been designed with the safety of the user in mind. However, due to the energy storage capacitor installed inside the power unit of the inverter, it may still carry a high voltage after disconnecting the power supply, and some parts generate a lot of heat, so contact is prohibited. When working on or near the inverter, please ...
|
|
The cause of bearing noise in different situations of frequency converters - Reynolds
1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...
|
|
Introduction to the appearance of Reynolds inverter
Bypass cabinet: The cabinet is equipped with high-voltage inlet and outlet isolation switches QS1 and QS2, as shown in Figure 2. Among them, QS1 is a single-pole single-throw variable frequency incoming knife switch, and QS2 is a single-pole double-throw power frequency and variable frequency outgoing knife switch. The bypass cabinet is a high-voltage environment, please observe the live display and electromagnetic lock status to ensure that the ...
|
|
Frequency conversion cabinet external conduit wiring method - Reynolds
When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods:
1. Kim ...
|
|
Tips for using reducers - Reynolds
1. After 200-300 hours of operation, the first oil change should be carried out, and the quality of the oil should be checked regularly in the subsequent use, and the oil mixed with impurities or deteriorated oil must be replaced in time. Under normal circumstances, the reducer for long-term continuous operation should be replaced after 5000 hours of operation or once a year.
|
|
Rated current analysis of inverter leakage circuit breaker
The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so a high frequency leakage current will occur, if you want to install a general leakage disconnect switch on the primary side of the inverter, it is recommended to select a sensitivity current of more than 200mA for each inverter and the action time is 0.1 seconds ...
|
|
Reynolds inverter parameter problem
1. What are the factory recovery parameters of Reynolds inverter?
N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective.
2. In the parameters of the N308 motor of the inverter, is the [motor leakage inductance reactance] specified sub-leakage inductance or rotor leakage inductance react?
Decide...
|
|
The inverter has no short-circuit protection for the reason – Reynolds
Short-circuit maintenance is a function of equipment connected between the power supply and the load, which can effectively disconnect the short-circuit point from the power supply when the load side is short-circuited. If an equipment has a short-circuit maintenance function, it must have a certain short-circuit breaking ability; And a device with the ability to break in a short circuit ...
|
|