The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important.

                               The lightning protection method of Reynolds inverter

Today's inverter products are generally equipped with a lightning absorption network, which is mainly used to avoid damage to the inverter due to instantaneous lightning intrusion. However, in practice, especially in the case of overhead introduction of power lines, the lightning absorption network that comes with the inverter alone cannot meet the requirements, and it is also necessary to set up a special lightning arrester for the inverter. Specific measures include:

(1) A special surge arrester for frequency conversion can be installed at the power supply inlet (optional);

(2) Or according to the standard requirements, the embedded steel pipe is 20m away from the inverter for special grounding protection;

(3) If the power supply is imported by cable, the lightning protection system in the control room should be done to prevent lightning from entering and damaging the equipment.

More on that
Indicator of Reynolds inverter cabinet wiring Indicator of Reynolds inverter cabinet wiring

Voltage level: The voltage level should match the voltage level of the power supply and motor to ensure electrical safety and normal operation of the equipment. Current level: The current level should match the rated current of the motor to ensure electrical safety and normal operation of the equipment. Cable Specification: Cable ...

Control method of Reynolds inverter Control method of Reynolds inverter

The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system. Typical wiring method for the main circuit of a Reynolds frequency converter ...

Precautions for installation of Reynolds low-voltage inverters Precautions for installation of Reynolds low-voltage inverters

1. Safety precautions 1. The primary requirement is to have certain electrical professional knowledge, and understand the job site, understand the equipment status, and have certain electrical operation technology. 2. Determine the electrical ...

Protection feature of overcurrent trip - Renol Protection feature of overcurrent trip - Renol

1. Maintenance objectives of overcurrent In the frequency conversion speed regulation system, there are two devices: the frequency converter and the motor. The degree of tolerance to overcurrent is not the same. The planners of the production machinery decide on the capacity of the motor based on the principle of heat. That is, as long as the electricity ...

Introduction to the function of the inverter - Reynolds inverter Introduction to the function of the inverter - Reynolds inverter

In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to collect, distribute, and transmit electrical energy. The connection methods of the bus bar are ...

The cause of the damage of the inverter - Reynolds inverter The cause of the damage of the inverter - Reynolds inverter

What are the causes of inverter damage? First, the heat dissipation of the inverter is not good In fact, we all know that too high a temperature can have a damaging effect on any device, just like the human brain, too high a temperature can also burn out the brain ...

Reynolds permanent magnet synchronous motor solutions Reynolds permanent magnet synchronous motor solutions

The permanent magnet synchronous motor has high-efficiency motor drive performance, which can complete high-speed, high-precision, high-stability, fast-responding, high-efficiency and energy-saving motion control. Reynolds drives provide a vector control technology solution for permanent magnet synchronous motors. ...

Reynolds JJR5000 Series Soft Starter Manual Reynolds JJR5000 Series Soft Starter Manual

Reynolds JJR5000 series all-digital intelligent communication motor soft engine adopts power electronics skills, microprocessor skills and modern control theory skills, and is a new type of engine equipment at the current level. The product can limit the starting current of the asynchronous motor when it starts, and is widely used in electric fans, ...

Reynolds inverter overhaul process Reynolds inverter overhaul process

1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...

Difference Between Soft Starter and Inverter – Reynolds Difference Between Soft Starter and Inverter – Reynolds

Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...

Dust design considerations for frequency converters - Reynolds frequency converters Dust design considerations for frequency converters - Reynolds frequency converters

1) The air duct of the inverter cabinet should be planned reasonably, and the exhaust should be clear and smooth, so as to avoid the formation of vortex in the cabinet and the accumulation of dust in a fixed direction. 2) The top air outlet of the inverter cabinet should be equipped with a protective top cover to avoid debris from falling directly.

Overheating failure light on start-up analysis - Reynolds Overheating failure light on start-up analysis - Reynolds

(1) Frequent starting, resulting in excessive temperature, causing overheating maintenance of soft starter. (The number of starts of the soft starter should be controlled to no more than 6 times per hour, especially for heavy loads) (2) During starting, ...

The working principle of the motor soft starter – Reynolds The working principle of the motor soft starter – Reynolds

Motor soft starter is the primary selection of power electronics skills and microprocessing skills and modern control theory and design and production of advanced level of new engine equipment, motor soft starter mainly has anti-interference function, high reliability, multiple protection functions and other characteristics, according to these characteristics of electric ...

Basic characteristics of inverter transmission - Reynolds Basic characteristics of inverter transmission - Reynolds

Compared with the motor driven by the inverter, the power factor and efficiency of the motor will deteriorate and the temperature rise will increase because the output waveform of the inverter contains the influence of higher harmonics. On the other hand, when the frequency conversion is driven, the same torque should be obtained as when the power frequency power supply is driven, ...

Classification of Reynolds inverter types Classification of Reynolds inverter types

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

The way to set the parameters of the inverter - Reynolds The way to set the parameters of the inverter - Reynolds

There are many setting parameters of the inverter, and each parameter has a certain range of choice, and the inverter can not work normally due to the improper setting of a single parameter in use, therefore, the relevant parameters must be set correctly. ...

Germany core control appeared at the China International Industry Fair Germany core control appeared at the China International Industry Fair

It is human beings who have always been committed to making human-computer interaction safer, easier to use, and more efficient, which has made collaborative robots gradually become the main stream of shopping malls. It is precisely because of the vigorous development of the collaborative robot industry that Synapticon Gmb ...

The external configuration of the inverter is solved - Reynolds The external configuration of the inverter is solved - Reynolds

With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...

Reynolds inverter FAQ - parameter class Reynolds inverter FAQ - parameter class

1. What are the factory parameters of inverter rehabilitation? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...

Inverter maintenance and undervoltage fault handling - Reynolds Inverter maintenance and undervoltage fault handling - Reynolds

In the repair of the inverter, we often hear about overpressure problems, but underpressure problems are also common problems encountered in the use of inverters. The reason is that the main circuit voltage is lower than the lower limit caused by the maintenance action or the damage of a rectifier bridge or the instantaneous power failure of the power grid, and the input is flat. Inverter after-sales ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top