Pierre Switches – Requirements for securing safety switches

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

The fastener itself needs to be reliable and stable enough.

It can be removed with specialized tools, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases they can be easily opened with fingernails or personal equipment.

Fasteners need to prevent themselves from loosening, and when appropriate, consider the necessity of elastic washers or screw glue.

It is necessary to prevent damage caused by foreseeable external shocks, and to judge the installation location according to the actual situation, such as the water level that is often walked away from people and forklifts often pass.

Mechanical switches need to be carried out within the specified operating range, especially for mechanical deadbolts, the length of which is fixed, if the installation distance is not calculated, it is easy to cause physical damage to the switch if it is often operated.

The safety door switch is not allowed to be used as a mechanical stop and mechanical stop for protection, and it is also to avoid damage to the switch body and operating head, reduce unnecessary physical impact as much as possible, and prevent safety failure and service life reduction
Pierre Switches – Requirements for securing safety switches

More on that
IEC 62443 – Industrial Information Security Standard – Pilz IEC 62443 – Industrial Information Security Standard – Pilz

The development of IT technology is changing all walks of life, automation is no exception, the degree of networking of production equipment and the use of standard protocols such as Ethernet for physical transmission of data has greatly increased, standardized protocols such as OPC UA allow access to controllers through IT systems, making data communication changeable.

Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5 Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5

PNOZ s5 belongs to the PNOZSigma family and is a safety relay with a time-delay function There are 8 terminal blocks on the top and bottom of the module, where: A1 and A2 are the terminal blocks of the module power supply; S11 and S12 are terminal blocks for a set of safety input channels; S21 and ...

Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association

The "Safety Standardization" theme exhibition organized by the China Machinery Industry Safety and Health Association and the National Machinery Safety Standardization Technical Committee was unveiled at the China Yiwu International Commodities (Standards) Expo held from November 24 to 27, 2022. Automation specialist Pilz was invited to participate in the exhibition to demonstrate ...

Peel magnetic relay - the application and current situation analysis of solid state relays Peel magnetic relay - the application and current situation analysis of solid state relays

Applications for Solid State Relays (1) The recommended value of the foreign SSR trigger signal (i.e., the current through the light-emitting tube) is 10mA DC, and the recommended value of the domestic SSR trigger signal is 12-25mA DC. (2) Multiple SSRs can use the same trigger signal, which is common in the control of three-phase AC loads.

Pilz will be exhibiting at LogiMAT 2023 Pilz will be exhibiting at LogiMAT 2023

From April 25 to 27, at the LogiMAT international logistics trade fair in Stuttgart, Germany, Pilz will present its safe and complete AGV safety automation solutions.   At Pilz's booth in Hall 6 – A21, visitors to the show will experience how AGVs are considering ...

How to match the user's drive circuit with the input characteristics of the solid state relay How to match the user's drive circuit with the input characteristics of the solid state relay

Generally speaking, the input control voltage of the solid state relay is 3.2-32V. The control current is 5-30mA.Usually the SSR input circuit of 1-2 is not a constant current source circuit, and the input control voltage is 4-16V. The control current is 5-20mA, and the SSR input circuit with the larger rated current is connected to the constant current source ...

The working principle and characteristics of Pilz safety relays The working principle and characteristics of Pilz safety relays

Pilz safety relays generally consist of an iron core, a coil, an armature, a contact reed, etc. As long as a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in an electromagnetic effect. Under the action of electromagnetic attraction, the armature overcomes the pulling force of the return spring and sucks in the iron ...

Maintenance method of Germany PILZ Peel magnetic relay Maintenance method of Germany PILZ Peel magnetic relay

Maintenance method: 1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Pilz: Safety scanners for AGVs Pilz: Safety scanners for AGVs

Automated Guided Vehicle, abbreviated as AGV, also commonly known as AGV trolley, refers to a transport vehicle equipped with electromagnetic or optical automatic navigation devices, which can drive along the specified navigation path, and has safety protection and various transfer functions. Due to its flexibility, the degree of intelligence ...

Pilz myPNOZ is even better suited to two-handed buttons Pilz myPNOZ is even better suited to two-handed buttons

The two-handed button is a commonly used safety start device, which is commonly used in punches, presses, cutting machines and other equipment; The purpose is to force the operator to leave the danger zone with his hands when driving the machine, so as not to come into contact with dangerous moving parts and cause safety accidents.   The "standard" of two-handed control says ...

Peel magnetic relays – what is the difference between a relay and a contactor Peel magnetic relays – what is the difference between a relay and a contactor

1. The effect is not the same: The primary effect of the relay is: signal detection, transmission, conversion or disposal, the circuit current it is on and off is generally small, and it is generally used in the control circuit to control weak signals. The primary effect of the contactor is to turn on or off the main circuit. Host...

Pilz: a product that can travel all over the world Pilz: a product that can travel all over the world

Whether Pilz products are to be used in Canada, Italy or China, Pilz customers do not have to worry about the required certifications.   The various quality marks on the products show that customers can rely on Pilz, for example in the modular safety relay myPNOZ: 1. By sticking ...

Safety circuit requirements for Peel magnetic relays Safety circuit requirements for Peel magnetic relays

1. When the emergency stop is lifted, the machine cannot be suddenly restarted 2. In case of failure of the safety circuit of the machine, the power supply of the machine can be stopped 3. When the safety circuit fails, the machine can no longer be started Confirm the safety of the transmission such as safety switches, light curtains, etc.

Peel magnetic relay - the selection principle of electromagnetic relays Peel magnetic relay - the selection principle of electromagnetic relays

1. Selection of relay coil application power supply Under normal circumstances, most of the relays of direct current are selected in the circuit design, and the types of power supplies used in relays can also be considered according to the characteristics of the control circuit. Secondly, it is necessary to think about the power consumed by the relay, and assume that the relay coil is supplied ...

Pilz: Bake delicious wafers safely Pilz: Bake delicious wafers safely

Franz Haas, the founder of the Bühler Group, invented the first wafer machine as early as the end of the 40s of the 20th century. Today, its subsidiaries are spread all over the world. In the wafer area of the consumer food division in Leobendorf, 700 employees are engaged in development, design and production, as well as sales, service, maintenance ...

Pilz - Presentation of the features of the safety relay PNOZ s60 Pilz - Presentation of the features of the safety relay PNOZ s60

In addition to the usual emergency stop monitoring, safety gate monitoring, light barrier monitoring and two-hand button monitoring, the safety relays of the PNOZsigma family are also functional, as well as safe speed monitoring, safe braking and braking monitoring. Voltage monitoring safety relays are also one of its features. PNO ...

Pilz PSEN safety sensor technology Pilz PSEN safety sensor technology

In combination with the safety controller, safety sensor technology from PSEN gives you the protection you covered! . Contactless magnetic safety switch PSENmag Magnetic switches can be used to monitor the position of mobile guards and are also suitable for difficult to precisely guide doors, which are susceptible to strong shocks.

Pilz safety light barriers provide safety for applications that require physical protection Pilz safety light barriers provide safety for applications that require physical protection

Pilz safety light curtains provide cost-effective safety for applications that require body protection. The safety light curtains have a wide operating range of up to 55 m and are ideally suited for the demarcation of external areas. Whether the user wants a single beam or a multi-beam encoder, in the PSENopt and PSENopt II series, there is a choice of 2 ...

The Pilz Safety PC PSS 4000 system provides customers with a better service The Pilz Safety PC PSS 4000 system provides customers with a better service

When building a safety system, it is particularly important to arrange the components of the safety system reasonably, which determines whether the reliability of the entire system can be guaranteed. Nowadays, with the gradual popularization of safety concepts, people's requirements for safety automation are getting higher and higher, and the scenarios of safety PLC applications are also increasing. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top