1. The effect is not the same:
The primary effect of the relay is: signal detection, transmission, conversion or disposal, the circuit current it is on and off is generally small, and it is generally used in the control circuit to control weak signals.
The primary effect of the contactor is to turn on or off the main circuit. The main circuit refers to whether a circuit is operated or not is marked by whether the circuit is turned on or not. The main circuit concept corresponds to the control circuit. Generally, the current passed through the main circuit is larger than that of the control circuit.
Contactors with large capacities are generally equipped with an arc extinguishing hood. The contact capacity of the relay generally does not cross 5A, the contact capacity of the small relay is generally only 1A or 2A, and the contact capacity of the contactor is the smallest 9A; The contactor contacts generally have three pairs of main contacts (the main contacts are normally open contacts), and there are several pairs of auxiliary contacts.
The contacts of the relay are generally not divided into main and auxiliary; The contacts of the relay are sometimes set in pairs, that is, the normally open and normally closed contacts are combined, while the contactors are not set in pairs; Relays are planned to be combined with other equipment for specific needs, such as time relays, counters, pressure relays, etc., which have additional functions, while contactors generally do not.
2. The opening and closing of the contacts are different:
Other contactors are used to turn on or off loads with high power, and are used in (power) main circuits, where the main contacts can have interlocking contacts to indicate the opening and closing of the main contacts.
Relays are generally used in electrical control circuits to extend the contact capacity of miniature or small relays to drive larger loads. For example, the contact of the relay can be used to turn on or off the coil of the contactor. Generally, relays have more opening and closing contacts, of course, relays can also end some special functions after proper connection, such as logical operations.
3. There is no arc extinguishing device:
In fact, looking at contactors and relays, one of the most important differences is that the contactors have arc extinguishing devices, while relays do not.
|
More on that
|
Peel magnetic relay – the role of intermediate relays
1. Replace small contactors: the contacts of the central relay have a certain ability to carry load, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. This not only serves the purpose of control, but also saves space, ...
|
|
Pilz: New rope pull switch - Mini model is more economical
Whether on the assembly line or on the machine, the safety rope pull switch is a proven and reliable solution for triggering an emergency stop function from any point on the pull rope to shut down dangerous work processes. Pilz's rope pull switch PSENrope is available in rope lengths up to ...
|
|
Pilz: It's easy to build your own customised safety relay
The myPNOZ Creator online tool, the configurator for the modular configurable safety relay myPNOZ, can be used via a PC with an Internet connection and no need for local installation in advance. Find the entrance to myPNOZ Creator on this page and start an extraordinary experience.
...
|
|
Pilz myPNOZ is even better suited to two-handed buttons
The two-handed button is a commonly used safety start device, which is commonly used in punches, presses, cutting machines and other equipment; The purpose is to force the operator to leave the danger zone with his hands when driving the machine, so as not to come into contact with dangerous moving parts and cause safety accidents.
The "standard" of two-handed control says ...
|
|
Pierre Servo Amplifier - Introduction to the parameters of the servo amplifier
Positional proportional gain
1. Set the proportional gain of the position ring adjuster;
2. The larger the setting value, the higher the gain, the greater the stiffness, and the smaller the position lag under the same frequency command pulse. However, too large a value may cause oscillation or overshoot;
3. Parameter value ...
|
|
Pilz was rated as an advanced unit of the National Printing Machinery Standardization Annual Conference
On March 1, 2023, the National Printing Machinery Standardization Annual Conference and the First National Coating Machine Standardization Annual Conference were held in Yiwu, Zhejiang. The meeting was guided by the Standardization Administration of the People's Republic of China, the China Machinery Industry Federation, and the Yiwu Municipal People's Government.
|
|
Peel magnetic relays – the difference between safety relays and general relays
1) Larger shape: The safety relay is different from the ordinary relay, and the safety relay is larger.
2) Modules instead of components: A safety relay is a module, not an electronic component like a normal relay.
3) Red and yellow: The safety relay has ...
|
|
Pilz: Overrun measurement – for safe distances
On machines with electrosensitive protective devices (e.g. laser scanners or light curtains), safety is ensured by the distance between hazardous movements and electrosensitive protective devices. Where there is intervention/access to the danger zone, there will be no more runaway movements.
Overrun is a dangerous movement that stops after a shutdown ...
|
|
Pilz: Safety control solution for SIL4 at rail level crossings
On fully enclosed rail transit lines, viaducts or tunnels are usually used to avoid the impact of rail lines on the distance, while on non-fully enclosed rail transit lines, the plane intersection between the railway and the distance, that is, level crossings, is more common.
In the early stage, rail transit ...
|
|
Pierre Switches – An introduction to the basics of safety switches
Features of the safety door switch:
The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. When the safety door is opened, the switch actuator is pulled out of the switch body and the normally closed contacts in the switch are disconnected by a mechanical rebound device. While...
|
|
Pilz is actively involved in the research and practice of Industrie 4.0
With the advancement of history, people have experienced the transformation from light industry to heavy industry, and then entered the era of automation brought about by innovation in the field of electronic computer technology and other scientific and technological fields.
The wisdom and potential of human beings are limitless, and today in the 21st century, we are experiencing new ...
|
|
Pilz: Machinery safety retrofit at the Heineken brewery
Brau Union is a beer production company from Austria that belongs to the famous beer brand Heineken Group, which supplies more than 5 million liters of beer per year. The company's largest brewery is in Wieselburg, which accounts for one-fifth of the year's beer supply. Within the Heineken Group, the ...
|
|
Peel magnetic relays - what are the connection methods of relays?
1. 3-pin relay wiring
The common 3-pin relay is the car horn relay.
No. 1 is the contact terminal, which connects the load;
No. 2 is the common terminal between the contact and the coil, which is connected to the power supply;
No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).
|
|
Pilz: IEC 62443 – Industrial Information Security Standard (Part II)
In the context of industrial automation, the term "safety" refers to the functional safety of equipment, which means that people and the environment are protected from damage from foreseeable coercion from machines, and the residual risk is more or less always present, but the residual risk cannot exceed the acceptable level. Through the use of security relay ...
|
|
Pilz leads the publication of the HRC Safety Application Guide
With the increasingly widespread use of industrial robots, the trend of China's manufacturing industry to a higher degree of automation has been bright, and the transformation and upgrading of China's manufacturing industry is on the way. The emergence of collaborative robots means that more intelligent robots will become the future intelligent system of China's manufacturing enterprises.
|
|
Requirements for Pilz to fix safety switches
Safety doors are mainly used to prevent the operation of the machine under certain conditions (usually when the guard is not closed) in order to avoid the occurrence of danger as much as possible. If the safety gate switch itself is not installed in compliance, resulting in its interlocking function not being implemented correctly, "it is time to do nothing", obviously ...
|
|
Steps for using Pilz safety relays
Pilz safety relays consist of several relays and circuits to compensate for each other's abnormal defects and achieve the full functionality of a relay with low misoperation or even correct relays. The lower the fault value and fault, the higher the safety factor. In order to prevent unavoidable misoperation or natural wear and tear of the machine, it should also be ...
|
|
Pilmagnetic switches – what are the requirements for a fixed safety switch?
1. The fastener itself needs to be reliable and stable enough.
2. Need to rely on special tools to remove, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases they can be easily fitted with fingernails or on the go.
|
|
Pilz: The path of innovation that began with the "mouse connection".
The debut of "Mouse Wire" in the world of automation dates back to 2002 at the SPS trade fair in Nuremberg, where Pilz presented users for the first time with a configurable small safety controller: no need to know a "higher-level" programming language, thanks to the ease of operation, the graphical ...
|
|
Common faults of Pilz safety relays with contacts and how to deal with them
The most common ones are the following:
(1) Contact failure
1. The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion formed on the contact and the pit biting each other), fusion welding, or cold welding.
2. Due to the contact resistance becoming large and unstable, the circuit cannot be normal ...
|
|