Safety circuit requirements for Peel magnetic relays

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

1. When the emergency stop is lifted, the machine cannot be suddenly restarted

2. In case of failure of the safety circuit of the machine, the power supply of the machine can be stopped

3. When the safety circuit fails, the machine can no longer be started

If it is not possible to confirm the safety of inputs such as safety switches and light curtains, how can we achieve a safety circuit? Is dual circuitry fine?

A: Dualization alone is not enough.

Dualization is necessary, but in addition to the following conditions, it is necessary to check each other of the dualized circuits, confirm that all safety circuits have been disconnected once, and if necessary, the operator can operate and start them. On the other hand, it is necessary to prevent sudden start-up of the machine if the input switch wiring is short-circuited or the wire sheath is damaged and the ground connection may be damaged.

In fact, in order to facilitate the composition of safety circuits, safety relays and other components are combined, and the products that form circuit modules with basic emergency stop circuits and safety circuits are called safety relay modules.
Safety circuit requirements for Peel magnetic relays

More on that
Pilz: New rope pull switch - Mini model is more economical Pilz: New rope pull switch - Mini model is more economical

Whether on the assembly line or on the machine, the safety rope pull switch is a proven and reliable solution for triggering an emergency stop function from any point on the pull rope to shut down dangerous work processes. Pilz's rope pull switch PSENrope is available in rope lengths up to ...

Pilz: How can I prevent my device from starting up unexpectedly? Pilz: How can I prevent my device from starting up unexpectedly?

In the process of adjustment, cleaning, maintenance and repair of mechanical equipment, the unexpected start of equipment due to various reasons is one of the most typical accident causes. Many companies may also be struggling with how to effectively control unplanned start-ups during maintenance. In order to have ...

Requirements for safety circuits for Pilz safety relays Requirements for safety circuits for Pilz safety relays

1. When the emergency stop is lifted, the machine cannot be suddenly restarted 2. In case of failure of the machine safety circuit, the power supply of the machine can be stopped 3. When the safety circuit fails, the machine can no longer be started Confirm safe input such as safety switches, light curtains, etc.

Pilz – an example of safety radar in the food industry Pilz – an example of safety radar in the food industry

The safety radar system PSENradar is a safe area protection monitoring device based on FMCW radar technology launched by Pilz, which is different from traditional area protection monitoring sensors, PSENradar is not easily affected by the external environment and is suitable for safe area protection monitoring under harsh conditions. ...

Peel magnetic relays – features of relay modules Peel magnetic relays – features of relay modules

  1. The same module can be triggered by high or low level through different wiring, and the trigger current is not less than 1mA, and the output capacity of the IO port of some 51 single-chip microcomputers is weak, and the circuit of pulling up or increasing the driving capacity is required (the default is low level triggering); 2. Advantages of low-level drive, ...

Pilz – how safety light curtains are safe to install Pilz – how safety light curtains are safe to install

1. The installation of the safety grating must be able to effectively prevent bypassing the detection area of the safety grating and contacting the dangerous moving parts, that is to say, the detection area of the installation grating can not have a blind spot, if the top or bottom of the safety grating has a fixed guard, the guard should be able to ...

Peel magnetic relays – Precautions for the selection of relay modules Peel magnetic relays – Precautions for the selection of relay modules

1. Whether the control voltage of the relay module is consistent with the system voltage. 2. It is still possible to use high level and low level for the level control mode of the relay module. 3. Depending on the requirements, choose whether you need a fully isolated relay module. 4. Safety: Relay ...

Pilz was rated as an advanced unit of the National Printing Machinery Standardization Annual Conference Pilz was rated as an advanced unit of the National Printing Machinery Standardization Annual Conference

On March 1, 2023, the National Printing Machinery Standardization Annual Conference and the First National Coating Machine Standardization Annual Conference were held in Yiwu, Zhejiang. The meeting was guided by the Standardization Administration of the People's Republic of China, the China Machinery Industry Federation, and the Yiwu Municipal People's Government.

Pilz: Overrun measurement – for safe distances Pilz: Overrun measurement – for safe distances

On machines with electrosensitive protective devices (e.g. laser scanners or light curtains), safety is ensured by the distance between hazardous movements and electrosensitive protective devices. Where there is intervention/access to the danger zone, there will be no more runaway movements. Overrun is a dangerous movement that stops after a shutdown ...

Pilz launches the maintenance system "Key in Pocket" Pilz launches the maintenance system "Key in Pocket"

The new maintenance system "key in pocket" from Pilz prevents the risk of unauthorised machine restarts and increases the safety of maintenance work. Digital maintenance assurance is based on the access authorization system PITreader, which ensures the safety of machinery and industrial information.

Pilz: It's easy to build your own customised safety relay Pilz: It's easy to build your own customised safety relay

The myPNOZ Creator online tool, the configurator for the modular configurable safety relay myPNOZ, can be used via a PC with an Internet connection and no need for local installation in advance. Find the entrance to myPNOZ Creator on this page and start an extraordinary experience. ...

The Pilz Safety PC PSS 4000 system provides customers with a better service The Pilz Safety PC PSS 4000 system provides customers with a better service

When building a safety system, it is particularly important to arrange the components of the safety system reasonably, which determines whether the reliability of the entire system can be guaranteed. Nowadays, with the gradual popularization of safety concepts, people's requirements for safety automation are getting higher and higher, and the scenarios of safety PLC applications are also increasing. ...

Pilz Safety Burner Management System Pilz Safety Burner Management System

An autonomously running burner management system has a complex structure and must comply with many international standards. Due to the high level of danger, strict safety regulations need to be applied to avoid the presence of unburned fuel in the combustion chamber. Pilz has a safe burner management system specifically tailored to these requirements. ...

Pilz myPNOZ is even better suited to two-handed buttons Pilz myPNOZ is even better suited to two-handed buttons

The two-handed button is a commonly used safety start device, which is commonly used in punches, presses, cutting machines and other equipment; The purpose is to force the operator to leave the danger zone with his hands when driving the machine, so as not to come into contact with dangerous moving parts and cause safety accidents.   The "standard" of two-handed control says ...

Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively

With the rapid development of industrial technology, on-site equipment is also developing towards a high degree of integration and automation. But no matter how the technology develops, behind the dazzling technology, the basic common equipment is always a solid backing. The hydraulic press is one of the old industrial basic equipment, and it is almost ...

REPAIR OF PILZ SAFETY RELAYS REPAIR OF PILZ SAFETY RELAYS

AS MENTIONED EARLIER, PILZ SAFETY RELAYS ARE THE MAIN COMPONENTS FOR CONTROL CIRCUITS AND MONITORING AND PROTECTION SYSTEMS FOR ELECTRIC LOCOMOTIVES. When the locomotive is running, when the motor, electrical appliances or connection lines in the main circuit and auxiliary circuit fail, the fault can be replaced by the Pilz safety relay of the corresponding monitoring and protection system.

Pilz: The best helper for safety control systems Pilz: The best helper for safety control systems

The safety control system generates a large amount of data at all times while ensuring the safety functions of its equipment. For example, when the E-STOP button is pressed, when someone opens a certain safety door, who switches the machine to service mode when, etc. This data is important for device managers ...

Pilz PSEN safety sensor technology Pilz PSEN safety sensor technology

In combination with the safety controller, safety sensor technology from PSEN gives you the protection you covered! . Contactless magnetic safety switch PSENmag Magnetic switches can be used to monitor the position of mobile guards and are also suitable for difficult to precisely guide doors, which are susceptible to strong shocks.

Pierz exhibited star products at the SIAF Guangzhou Automation Exhibition Pierz exhibited star products at the SIAF Guangzhou Automation Exhibition

At the SIAF Guangzhou Automation Exhibition, which opened on March 10th, Pilz once again brought new automation solutions to visitors under the concept of "WeAutomate Safely". The exhibition ...

Pierz switches – what are the properties of safety switches? Pierz switches – what are the properties of safety switches?

The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top