Pilz - Presentation of the features of the safety relay PNOZ s60

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

In addition to the usual emergency stop monitoring, safety gate monitoring, light barrier monitoring and two-hand button monitoring, the safety relays of the PNOZsigma family are also functional, as well as safe speed monitoring, safe braking and braking monitoring. Voltage monitoring safety relays are also one of its features.

PNOZ s60 is an upgrade to the original PNOZ X series PU3Z for the safe monitoring of single-phase or three-phase power supplies with neutral conductors. The product measures the three-phase voltage and activates the safety circuit only when the value falls below the threshold. If the system is energized after a shutdown due to a mechanical failure, such as soldering of the contacts on the main switch, PNOZ s60 reliably avoids access to the machine. By monitoring the safe voltage-free condition, it is also possible to ensure that the repair work of equipment and machinery can be carried out safely.
Pilz - Presentation of the features of the safety relay PNOZ s60

wield

PNOZ s60 can be used as a core component of the Safety Determination System (SLS) and, together with a small controller (e.g. PNOZmulti), ensures safe access to plant and machinery (which can be safely de-energized). The PNOZ s60 safety voltage monitor meets the requirements of UL 6420 for the implementation of SLS, which simplifies the requirements for lockout-of-sale (LoTo) in stores in the United States. In order to meet the requirements of individual occupations, the PNOZ s60 voltage monitor has two adjustable thresholds, which are 12 V or 6 V, which are common in food and beverage occupations. Reduce downtime by integrating LEDs to quickly and easily diagnose devices.

Technical characteristics:

• Meets the requirements of UL 6420

• Output contacts: -3NO/1NC, 7 SO

• Universal power supply 24 – 48 VAC/DC, 100 – 240 VAC/DC

• Diagnosis is confirmed by LEDs

• Width: 90 mm

• Pluggable terminal blocks (spring or screw)

• Expansion modules can be used with PNOZsigma contacts

• Certifications: CCC, CE, EAC, TÜV, UL

As a safety specialist from Germany, Pilz assists customers all over the world in the automation of machinery and plants and always strives to provide customers with the best solutions.

More on that
Peel magnetic relay - the wiring method, function and application of time relay Peel magnetic relay - the wiring method, function and application of time relay

Wiring method of time relay 1. Control wiring You think of it as a DC relay. 3. 7 is used to connect to 12V control voltage; 2. 7 is used to connect to 24V control voltage. 7 of them are used as the negative electrode of direct current, which is connected to the neutral line when used. 2. Connect to a 220V live wire. 2 ...

ANALYSIS OF THE WORKING PRINCIPLE OF PILZ SAFETY RELAYS ANALYSIS OF THE WORKING PRINCIPLE OF PILZ SAFETY RELAYS

Germany Pilz automatic switching element with isolation function PILZ relay: PILZ relay is an automatic switching element with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the important control components. ...

Functions of Pilz Functions of Pilz

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Pilz: The path of innovation that began with the "mouse connection". Pilz: The path of innovation that began with the "mouse connection".

The debut of "Mouse Wire" in the world of automation dates back to 2002 at the SPS trade fair in Nuremberg, where Pilz presented users for the first time with a configurable small safety controller: no need to know a "higher-level" programming language, thanks to the ease of operation, the graphical ...

Pilz has launched the new stand-alone base module PNOZ m C0 Pilz has launched the new stand-alone base module PNOZ m C0

In the safe configurable small controller series PNOZmulti 2 from Pilz, a new stand-alone base module PNOZ m C0 is now available. PNOZ m C0 has the structural characteristics of a safety relay, but it is just as powerful as a safety controller. It offers 8 ...

Pilz: New system version PSS 4000 1.24 Pilz: New system version PSS 4000 1.24

The automation system PSS 4000 offers new features in the new version 1.24. Here's what you need to know:   New data types FIXED and LFIXED The data types FIXED (a fixed digit with 6 decimal places) and LFIXED (a fixed number with 11 decimal places) are now ...

Pilz: How can I prevent my device from starting up unexpectedly? Pilz: How can I prevent my device from starting up unexpectedly?

In the process of adjustment, cleaning, maintenance and repair of mechanical equipment, the unexpected start of equipment due to various reasons is one of the most typical accident causes. Many companies may also be struggling with how to effectively control unplanned start-ups during maintenance. In order to have ...

Requirements for safety circuits for Pilz safety relays Requirements for safety circuits for Pilz safety relays

1. When the emergency stop is lifted, the machine cannot be suddenly restarted 2. In case of failure of the machine safety circuit, the power supply of the machine can be stopped 3. When the safety circuit fails, the machine can no longer be started Confirm safe input such as safety switches, light curtains, etc.

Peel magnetic relay - the application and current situation analysis of solid state relays Peel magnetic relay - the application and current situation analysis of solid state relays

Applications for Solid State Relays (1) The recommended value of the foreign SSR trigger signal (i.e., the current through the light-emitting tube) is 10mA DC, and the recommended value of the domestic SSR trigger signal is 12-25mA DC. (2) Multiple SSRs can use the same trigger signal, which is common in the control of three-phase AC loads.

Peel Magnetic Relays – How to Choose a Solid State Relay Peel Magnetic Relays – How to Choose a Solid State Relay

The naming of solid state relay models has not been unified, and the following conditions should be considered when selecting the manufacturer's manual. (1) Rated input voltage Refers to the maximum allowable effective voltage of a steady-state resistive load that can be withstood under a given condition. When used for inductive loads ...

Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5 Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5

PNOZ s5 belongs to the PNOZSigma family and is a safety relay with a time-delay function There are 8 terminal blocks on the top and bottom of the module, where: A1 and A2 are the terminal blocks of the module power supply; S11 and S12 are terminal blocks for a set of safety input channels; S21 and ...

Pilz: a product that can travel all over the world Pilz: a product that can travel all over the world

Whether Pilz products are to be used in Canada, Italy or China, Pilz customers do not have to worry about the required certifications.   The various quality marks on the products show that customers can rely on Pilz, for example in the modular safety relay myPNOZ: 1. By sticking ...

Peel magnetic relay – the difference between a transistor and a relay output PLC Peel magnetic relay – the difference between a transistor and a relay output PLC

1. The overload capacity of the transistor is less than the overload capacity of the relay In general, in the case of a large inrush current (e.g., bulbs, inductive loads, etc.), the transistor overload capability is smaller, and more derating is required. 2. Under the condition of rated operation, the relay has the number of actions ...

Peel magnetic relays – a common fault of electromagnetic relays Peel magnetic relays – a common fault of electromagnetic relays

1. After the power failure, the armature cannot be released immediately, which may be due to the stuck movable core, the core air gap is too small, the spring strain and the oil caused by the core contact surface, etc. Universal relay maintenance should be treated differently by the cause of failure, or adjust the air gap to protect it from 0.02 to 0.05 mm, ...

How to match the user's drive circuit with the input characteristics of the solid state relay How to match the user's drive circuit with the input characteristics of the solid state relay

Generally speaking, the input control voltage of the solid state relay is 3.2-32V. The control current is 5-30mA.Usually the SSR input circuit of 1-2 is not a constant current source circuit, and the input control voltage is 4-16V. The control current is 5-20mA, and the SSR input circuit with the larger rated current is connected to the constant current source ...

Pilz: Flexible and secure access rights management Pilz: Flexible and secure access rights management

Pilz's new electronic access system, the PITreader card unit, can be used to manage machine access flexibly and securely. With the PITreader card unit, the operator can now assign permissions in the form of cards or stickers on the RFID transponder. The machine operator is responding to ...

Pilz: Safety in the production of lithium-ion batteries Pilz: Safety in the production of lithium-ion batteries

With the rapid rise of new energy vehicles, the lithium battery industry has also ushered in explosive growth. The production process of lithium battery is more complex, and the production process of different battery types is also different, but the manufacturing process is roughly the same, which is the front process (pole piece production), the middle ...

Pilz: A new version is here! This time it's more powerful Pilz: A new version is here! This time it's more powerful

Since its launch, Pilz's flagship product, the configurable and safe small controller PNOZmulti, has been impressed by users for its robustness, flexibility and ease of operation. PNOZmulti Configurator as a configuration tool for the safe small controller PNOZmulti ...

Pierre Magnetic Switches – What are the functions of safety door switches? Pierre Magnetic Switches – What are the functions of safety door switches?

1. The security door can also be called the anti-theft door, and the safety door switch, as the name suggests, is an automatic inductive control switch to ensure the safety of the door, and the opening and closing of the door needs to be detected by it to open and close. For example, this kind of safety door switch will be used in the community or factory, traffic, etc., which is conducive to monitoring ...

Pilz switches – how to install safety switches Pilz switches – how to install safety switches

1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm. 2) Where the socket must be facing the switch panel ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top