Precautions for driver grounding in the Yaskawa servo drive manual

1. The correct shield grounding point is at the reference potential inside the circuit, which depends on the noise source and reception

Whether it is grounded at the same time, or floating.

2. Make sure that the shield is grounded at the same point so that the ground current will not flow through the shield.

3. Avoid the ground loop generated by a variety of connection methods to the earth is easily affected by noise and generate current at different reference points.

4. In the case that there is no isolation between the AC power supply and the DC bus of the driver, the non-isolated port or non-isolated signal of the DC bus cannot be connected to the ground, which will lead to equipment damage and personnel injury.

5. Avoid the servo drive being connected to the ground of the external power supply, which will directly affect the work of the controller and the driver.

6. The common voltage of AC is not to the ground, and there may be a high voltage between the DC bus and the earth, and it is forbidden to directly connect to the ground.

7. In the servo system, the common ground and the earth must be connected together at the signal end.

8. In order to keep the command reference voltage constant, the signal of the servo drive should be connected to the signal ground of the controller.
Precautions for the use of Yaskawa servo drives

More on that
Yaskawa V1000 inverter alarm CPF06 fault maintenance after powering on Yaskawa V1000 inverter alarm CPF06 fault maintenance after powering on

1. Fault phenomenon: The fault phenomenon is the alarm CPF06 after power-on, which cannot be reset. Second, the maintenance method: The explanation for the CPF06 fault reported by Yaskawa V1000 inverter is: EEPROM data is abnormal. Generally, it is possible to restart the inverter or perform initialization ( A1-03=2220 ) ...

Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way

Not long ago, it was found from the national enterprise information management system that the joint venture industrial manipulator enterprise founded by Midea and Yaskawa Electric announced the record cancellation/announcement information on April 12, and had already established a liquidation team to accept debt applications. The joint venture is a joint venture in Guangdong ...

How to deal with the occurrence of OL2 in Yaskawa inverter How to deal with the occurrence of OL2 in Yaskawa inverter

OL2 is the inverter overload alarm, check whether it is a real overload or a false overload. 1. Test whether the output current of the inverter exceeds the rated current of the inverter, if it exceeds it, it may be the mechanical reason, if it does not exceed the inverter detection circuit is broken, and the false overload is reported. ...

Yaskawa robot servo motor burnout repair method Yaskawa robot servo motor burnout repair method

There are three main burning methods for common Yaskawa robot servo motors: overload, phase loss, and short circuit. 1. Overload: Open the servo motor of the industrial robot to observe. The color of the entire winding wire pack has become dark and black, the end strap is cracked, and the serious phase insulation and notch insulation are due to overheating.

The basic operation of Yaskawa robots The basic operation of Yaskawa robots

First, the correct boot steps: Yaskawa robot 1. Turn on the power switch of the transformer and press the power [start] button. 2. Turn on the [power switch] of the control box, and press the [servo button] according to the prompts on the screen of the instructor 2. Simple operation of the robot ...

Yaskawa inverter maintenance method Yaskawa inverter maintenance method

Yaskawa inverter failure and maintenance method.   The switching power supply is damaged. Switching power supply damage is the most common fault in many frequency converters, usually caused by a short circuit in the switching power supply load. The 616G3 uses two switching power supplies, which is somewhat similar to the Fujifilm G5. First of all, the DC bus side 530 volts ...

Yaskawa servo motor - the working principle and basic requirements of servo drive Yaskawa servo motor - the working principle and basic requirements of servo drive

At present, the mainstream servo drives all use digital signal processors (DSPs) as the control core, which can realize more complex control algorithms and realize digitalization, networking and intelligence. Power devices generally use the drive circuit designed with intelligent power module (IPM) as the core.

A brief overview of the Yaskawa GP20HL robotic protective suit A brief overview of the Yaskawa GP20HL robotic protective suit

Yaskawa GP20HL robot is a kind of hollow arm six-axis industrial robot, which is mainly used in automatic production lines such as assembly and material handling, which can not only replace manual work tasks, but also do not affect its operation efficiency. So as its protective product, the Yaskawa GP20HL robot protective suit is ...

Yaskawa made its debut at the AMB - Robotics Innovation Trade Fair Yaskawa made its debut at the AMB - Robotics Innovation Trade Fair

As a long-standing and reliable supplier of automated metalworking solutions, Yaskawa will be exhibiting at AMB for the first time. Possible applications for the company's Motoman robots include tool handling, machining and stacking workpieces, and machine loading. At booth 6D50 in Hall 6, ...

Yaskawa robot spraying process application virtual simulation operation method Yaskawa robot spraying process application virtual simulation operation method

Spraying is another common process application of industrial robots, second only to welding process applications, and they all belong to high-intensity, high-precision, and high-sensitivity work tasks in harsh environments. The spraying process has extremely high requirements for the performance of the robot, of course, for the formulation of the process, ...

Advantages of Yaskawa servo motors Advantages of Yaskawa servo motors

1. The highest amplifier responsiveness in the industry, with a speed and frequency response of 1.6kHz Second, the greatly enhanced vibration control function. 3. The maximum speed is increased to 6000 rpm Fourth, the temperature rise is reduced, the efficiency is improved, and the peak torque is increased to 350% Fifth, the first day ...

Robotics propelled Yaskawa Electric to record profits Robotics propelled Yaskawa Electric to record profits

Yaskawa Electric, one of the world's largest manufacturers of industrial robots, announced a 150% year-on-year increase in net profit for the six months ended Sept. 30. The Japan company announced that the company reported a profit for the quarter due to the demand for its industrial robots in China, Japan and United States.

Yaskawa Electric's development areas Yaskawa Electric's development areas

Drive control Yaskawa Electric's Drive Control Division has achieved a leading position in the industry by integrating and commercializing various innovations and the world's latest technologies into inverters. These technologies have penetrated into various fields as world standards, and the quality, performance, ...

Yaskawa servo drive fault code and handling method Yaskawa servo drive fault code and handling method

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

Yaskawa Robotics School Origin Steps Yaskawa Robotics School Origin Steps

1. Yaskawa robot teach pendant key switch to manual Teach mode - main menu - system information - security mode 2. Management mode - password - 999999999 3. Robot - Origin location 4. Open the door of the robot control cabinet and there is a mechanical prototype with 6 axes of the robot on the side.

Fault codes for Yaskawa servo drives Fault codes for Yaskawa servo drives

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry

1. The demand for smart sensors is increasing Quality inspection is a key component in all industries. Analyzing everything from food to phone covers ensures that consumers can trust the goods they receive. Smart sensors enable manufacturers to more efficiently handle this ...

Parameterization steps of Yaskawa inverter Parameterization steps of Yaskawa inverter

1. Enter the parameter menu, select the "Motor Current" item, and set the rated current of the motor In 2. Select the "Overload Protection" item to enter a form: select to enter the overload fixed value multiplier. The overload fixed value magnification range is 100-700%, just enter the number between 100 and 700.

Yaskawa Robotics – How does the Robot Perception System work? Yaskawa Robotics – How does the Robot Perception System work?

The robot perception system transforms various internal state information and environmental information of the robot from signals to data and information that can be understood and applied by the robot itself or between robots, in addition to the need to perceive mechanical quantities related to its own working state, such as displacement, velocity, acceleration, force and force.

Parameter setting steps of Yaskawa H1000 inverter Parameter setting steps of Yaskawa H1000 inverter

1. No-load power-on test of inverter 1. Ground the grounding terminal of the inverter. 2. Connect the power input terminal of the inverter to the power supply through the leakage protection switch. 3. Check whether the factory display of the inverter display window is normal, if it is incorrect, it should be reset, otherwise ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top