Drive control
Yaskawa Electric's Drive Control Division has achieved a leading position in the industry by integrating and commercializing various innovations and the world's latest technologies into inverters. These technologies have penetrated into various fields as world standards, and the quality, performance, and function of inverters have secured a certain market share.
Motion control
Yaskawa Electric is a professional manufacturer in the field of motion control, is the first company in Japan to do servo motors, its products are known for stable and fast, cost-effective, is the world's largest sales, the most used servo brand. In China, Yaskawa Servo has occupied a certain market share for many years. From general industrial machinery to semiconductor and electronic component manufacturing equipment, we offer the best servo and controller products for a variety of applications.
Yaskawa servo motors are mainly divided into four series: Σ-I., Σ-II., Σ-III., and σ-v., and Σ-I. and Σ-II (except for large capacity) have been discontinued. The Σ-V. series has the widest audience in China. There is also a simple servo product Junma series.
System control
Mainly for metallurgy, electric power, cement, municipal, petrochemical and other industries with high-voltage inverter sales and technical services, at the same time engaged in Japan Yaskawa electrical system engineering department CP series controller, high and low voltage AC and DC transmission devices, high and low voltage AC and DC motors, related supporting devices and other engineering products sales and service window work.
robot
The multi-function robot Motoman is a multi-functional robot that is constantly evolving with the concept of "providing solutions", and we provide the most suitable solutions for a wide range of needs and diverse problems while emphasizing communication and dialogue between customers, and we provide full support for the FA.CIM system
|
More on that
|
Common fault analysis and treatment methods of Yaskawa inverter
1. OC1 and OC3 are faulty
In many cases, the occurrence of OC (overcurrent fault) in Yaskawa inverter will be caused by the following reasons (now take A500 series inverter as an example):
(1) Caused by improper parameter setting, such as time setting is too short;
(2) Internal ...
|
|
Yaskawa inverter fault display Ou how to deal with the fault when running at high speed
1. The cause of the failure may be that the power plug is not plugged in properly.
Solution: Check and plug in the power plug.
2. The sensor is damaged and the resistance value is wrong.
Solution: Replace the sensor.
3. The fuse is blown out.
Solution: Repair and replace the fuse ...
|
|
The cause of the failure of the inverter and its maintenance treatment
One. The type of failure and the reason for the failure
1. The type of failure
Faults are divided into power supply faults, internal faults, and load faults.
Power failure: There is a fault in the power grid connected by the inverter
Internal fault: The failure of the drive itself
Load Failure: ...
|
|
Yaskawa servo drive maintenance alarm C90, AC9 fault handling method
1. Analysis of the causes of Yaskawa servo alarm C90 (AC9):
1. The encoder cable is broken or the encoder plug is made in poor process (there are also wiring errors in the alarm of the new machine);
2. The servo drive itself is faulty;
3. Environmental interference, caused by poor connection: ...
|
|
Yaskawa Robot - the basic function of the robot control system
(1) Memory function: store operation sequence, motion path, motion mode, motion speed and information related to production process;
(2) Teaching function: offline programming, online teaching, indirect teaching. There are two types of online teaching: teaching box and guided teaching;
(3) With ...
|
|
Common faults and maintenance methods of Yaskawa robot servo drive
1. Robot digital AC servo system MHMA 2KW, as soon as the test machine is powered on, the motor vibrates and has a lot of noise, and then the driver appears No. 16 alarm, how to solve it?
This phenomenon is generally due to the driver's gain setting being too high, resulting in self-oscillation. Please tune in ...
|
|
Performance characteristics of Yaskawa servo motors
Superior performance
"I hope to run the machine at a faster speed and with higher precision" ----∑-V. series servo, the performance of which is the best in the industry.
It has the highest amplifier responsiveness in the industry, which greatly shortens the setting time
It is only 1/12 of our conventional products
...
|
|
Yaskawa servo motor - ten common faults and troubleshooting methods of servo motors
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
(1) Check the wiring and eliminate the error ...
|
|
Parameterization steps of Yaskawa inverter
1. Enter the parameter menu, select the "Motor Current" item, and set the rated current of the motor In
2. Select the "Overload Protection" item to enter a form: select to enter the overload fixed value multiplier. The overload fixed value magnification range is 100-700%, just enter the number between 100 and 700.
|
|
Yaskawa inverter performance advantages
The full name of Yaskawa inverter is "Yaskawa AC inverter governor", which is mainly used in three-phase asynchronous AC motors to control and adjust the speed of the motor. Yaskawa inverter is famous all over the world and has a very high share in the Chinese market for many years. Motor knowledge derived from Yaskawa Electric's input, ...
|
|
Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way
Not long ago, it was found from the national enterprise information management system that the joint venture industrial manipulator enterprise founded by Midea and Yaskawa Electric announced the record cancellation/announcement information on April 12, and had already established a liquidation team to accept debt applications.
The joint venture is a joint venture in Guangdong ...
|
|
Yaskawa MOTOMAN servo drive fault repair case summary (1-2)
1. The motor runs faster in one direction than in the other;
(1) Cause of failure: The phase of the brushless motor is wrong.
Solution: Detect or detect the correct phase.
(2) Cause of failure: When not used for testing, the test/deviation switch hits the test position ...
|
|
Yaskawa servo motor - common faults and maintenance methods of servo drives
1. The LED light is green, but the motor does not move
(1) Cause of failure: The motor in one or more directions is prohibited from operating.
Solution: Check the +INHIBIT and –INHIBIT ports.
(2) Cause of failure: The command signal is not to the driver signal.
...
|
|
How to deal with Yaskawa servo alarm 840?
1. Encoder malfunction. When the power is turned on again and this alarm still occurs, it is possible that the servo motor is faulty, and the servo motor is replaced;
2. Encoder malfunction due to noise and other interference. Correct handling of the wiring around the encoder (separating the encoder cable from the servo motor ...
|
|
The operation steps of the Yaskawa robot
1. Turn on the power switch and compressed air switch of Yaskawa robot.
2. Turn on the main power switch on the Yaskawa robot control cabinet. After the robot completes the self-test, press the servo power button to turn on the servo power supply of the motor. Press the teach-in button (TEACH) on the control cabinet to make the machine ...
|
|
The frequency of the frequency converter is given in a given way
1. The simplest way to give the frequency of the inverter is to complete it through the operation panel, and users can usually change the set frequency directly through the potentiometer, digital key or rising and descending keys on the generator panel. The biggest advantage given by the operator panel is that it is simple, ...
|
|
What are the main characteristics of Yaskawa industrial robots?
Programmable: You can program your robot to run in the production process based on your industry needs.
Anthropomorphism: Industrial robots resemble humans in that they move hands, legs, forearms, arms, and other parts of the body. Even today, in some industries ...
|
|
How to cancel the Yaskawa robot collision alarm?
1. Enter the management mode and click on the robot.
2. Click on the collision detection level, enter the designated page, select the collision detection file number, enter 9, and press enter.
3. Change the function from valid to invalid. After the robot action is restored, it can be changed back to effective.
...
|
|
Common fault causes and solutions for servo drives
1. The LED light is green, but the motor does not move
(1) Cause of failure: The motor in one or more directions is prohibited from operating.
Solution: Check the +INHIBIT and –INHIBIT ports.
(2) Cause of failure: The command signal is not to the driver signal.
...
|
|
How to adjust the multi-stage speed of Yaskawa V1000 inverter?
Yaskawa Inverter A1000 User Guide 1. Description of the operator: (1). Keyboard description:
【ESC】Function:
1. Return to the previous screen;
2. Shift the bit that needs to be changed when setting the parameter number to the left;
3. If you press and hold it, you can ...
|
|