Fault codes for Yaskawa servo drives

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply;

2. If the fault code on the Yaskawa servo drive is UV2, it means that the low voltage of the control loop is lower than the low voltage standard, and we need to check whether the capacity of the power supply is normal;

3. If the fault code on the Yaskawa servo drive is UV3, it means that the electromagnetic contactor inside the inverter may be faulty

4. If the fault code on the Yaskawa servo drive is UV, then there may be an instantaneous power outage, the main reasons are as follows, the first is that the voltage of the main circuit is lower than the voltage standard, and the second may be that the contactor is faulty;

5. If the fault code on the Yaskawa servo drive is OC, then the output current of the inverter may exceed the output current standard, and we need to check whether the impedance insulation of the inverter is working normally;

6. If the fault code on the Yaskawa servo drive is GF, then it means that the inverter has a grounding fault, at this time, I need to check whether the inverter has a fault of insulation deterioration, and at the same time, we also need to check whether the wiring of the inverter is damaged;

7. If the fault code on the Yaskawa servo drive is OV, then it means that the DC voltage of the main circuit is higher than the overvoltage standard of 200V:

8. If the fault code on the Yaskawa servo drive is SC, then it means that the inverter has a load short circuit, we need to check whether there is a short circuit on one side of the inverter output, and then check whether the insulation and impedance of the inverter are normal;

9. If the fault code on the Yaskawa servo drive is PUF, then it means that the fuse inside the inverter is broken, it may be that the fuse of the main circuit is blown out, or the fuse of the DC circuit is blown out, and then we need to check whether the work of the crystal module is normal, and then check that the load is not short-circuited.
Fault codes for Yaskawa servo drives

More on that
Analysis of fault codes of Yaskawa inverter Analysis of fault codes of Yaskawa inverter

Analysis of the fault code of Yaskawa inverter, for reference only: OC Overcurrent The output current of the inverter exceeds the overcurrent detection value · GF grornd Favlt Grounding The ground current on the output side of the inverter exceeds 50% of the rated output current of the inverter ...

Common faults of Yaskawa robot and how to deal with them (11-17) Common faults of Yaskawa robot and how to deal with them (11-17)

11. Robot jitter? Diagnostic process: Due to the difference between the jitter area and the amount of jitter, the diagnosis of jitter becomes a difficulty. At this stage, the diagnostic method is to replace the amplifier, replace the motor, and replace the reducer one by one. Improvement method: ...

Yaskawa inverter fault code description and corresponding fault causes Yaskawa inverter fault code description and corresponding fault causes

When the Yaskawa inverter fails, the operator will display the fault content, cut off the output, and the motor will decelerate and stop freely. The following is a description of the fault alarm code of Yaskawa inverter and the corresponding fault reason, which is for reference only. OC Overcurrent ...

MindMotion Technology joined hands with Yaskawa Shougang to appear on the CCTV screen again MindMotion Technology joined hands with Yaskawa Shougang to appear on the CCTV screen again

Recently, after appearing on CCTV news during the Beijing Winter Olympics, MindMotion Technology and Yaskawa Shougang appeared on the CCTV stage again, demonstrating the application achievements of the two sides in jointly building an advanced manufacturing cluster in the field of intelligent manufacturing and enhancing the competitiveness of the industrial chain and supply chain. It was reported in the news that the new ...

Yaskawa servo motor - common faults and maintenance methods of servo drives Yaskawa servo motor - common faults and maintenance methods of servo drives

1. The LED light is green, but the motor does not move (1) Cause of failure: The motor in one or more directions is prohibited from operating. Solution: Check the +INHIBIT and –INHIBIT ports. (2) Cause of failure: The command signal is not to the driver signal. ...

Yaskawa inverter – the future of high-voltage inverters Yaskawa inverter – the future of high-voltage inverters

1. High-voltage inverter will develop in the direction of high power, miniaturization and lightweight. 2. The high-voltage inverter will develop in the direction of direct device high voltage and multiple superposition (device series and unit series). 3. New power semiconductors with higher voltage and higher current ...

Yaskawa Robotics – How does the Robot Perception System work? Yaskawa Robotics – How does the Robot Perception System work?

The robot perception system transforms various internal state information and environmental information of the robot from signals to data and information that can be understood and applied by the robot itself or between robots, in addition to the need to perceive mechanical quantities related to its own working state, such as displacement, velocity, acceleration, force and force.

Yaskawa H1000 inverter overload oL2 fault Yaskawa H1000 inverter overload oL2 fault

There are two types of inverter overload faults: 1. If there is a problem with the load, it is a problem with the motor, such as the lack of oil in the bearing, the damage to the bearing, the burning of the winding, etc., and there is a situation that the power of the motor is small, and it is more difficult to drag the load. 2. It is the inverter ...

How to deal with Yaskawa servo alarm 840? How to deal with Yaskawa servo alarm 840?

1. Encoder malfunction. When the power is turned on again and this alarm still occurs, it is possible that the servo motor is faulty, and the servo motor is replaced; 2. Encoder malfunction due to noise and other interference. Correct handling of the wiring around the encoder (separating the encoder cable from the servo motor ...

Introduction to the characteristics of Yaskawa arc welding robot Introduction to the characteristics of Yaskawa arc welding robot

1. Coordinated control technology: control the coordinated movement of multiple robots and positioners, which can not only maintain the relative attitude of the welding gun and the workpiece to meet the requirements of the welding process, but also avoid the collision of the welding gun and the workpiece. Yaskawa Robotics is a multi-articulated manipulator or multi-degree-of-freedom robot for the industrial field. ...

Explain in detail the setting method of arc static during welding of Yaskawa welding robot Explain in detail the setting method of arc static during welding of Yaskawa welding robot

1. Conditions for the static characteristics of the arc of Yaskawa welding robots In the welding production process, once the electrode material, gas medium and arc length are maintained, as long as the arc of the Yaskawa welding robot can burn stably, the welding current and arc voltage will show corresponding changes.

How to deal with the fault Fn000 reported by Yaskawa servo drive How to deal with the fault Fn000 reported by Yaskawa servo drive

1. Check whether the encoder cable is good and carefully check the coding cord plug. Whether the soldering points and cable bow and foot row are normal; 2. If no wire and plug problems are found, rule out the interference of the encoder cable, please separate the encoder cable from other wires (power cables); 3. Line ...

Yaskawa servo drive parameters Yaskawa servo drive parameters

PN000 function selection N.0010 (setting value) 0th position: set the direction of rotation of the motor; Set "1" to change the rotation of the motor in reverse. 1st position: Set the control mode to: "1" position control mode. PN200 Command Pulse Input Mode Function Selection N.0101 (Set Value) "1" Positive ...

How to deal with the occurrence of OL2 in Yaskawa inverter How to deal with the occurrence of OL2 in Yaskawa inverter

OL2 is the inverter overload alarm, check whether it is a real overload or a false overload. 1. Test whether the output current of the inverter exceeds the rated current of the inverter, if it exceeds it, it may be the mechanical reason, if it does not exceed the inverter detection circuit is broken, and the false overload is reported. ...

Yaskawa inverter – how to check for inverter failure Yaskawa inverter – how to check for inverter failure

1. Static test 1. Test the rectifier circuit Find the P and N ends of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, connect the red watch rod to P, and separate the black watch rod to R, S, T. Instead, take the black watch rod ...

Yaskawa inverter - what are the application fields of low-voltage inverter? Yaskawa inverter - what are the application fields of low-voltage inverter?

1. Fan With the continuous development of industry, the application of fans is becoming more and more extensive, especially in the chemical, stone and textile industries. However, there is a general problem of over-air volume in the design of the fan, and throttling is generally used when the air volume needs to be adjusted, that is, the damper is adjusted.

Common faults and solutions of Yaskawa servo drives Common faults and solutions of Yaskawa servo drives

1. When the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read; Cause of failure: The current monitoring output is not isolated from the AC power supply (transformer). Solution: It can be detected and observed with a DC voltmeter. 2. Motor ...

How to replace the bearing of Yaskawa servo motor? How to replace the bearing of Yaskawa servo motor?

1. Preparation before servo motor bearing replacement 1. Take the servo motor off the device position and make it in a state that is easy to operate in the working environment; 2. Touch the bearing by hand to determine whether it has been damaged or worn; 3. According to the requirements of the manufacturer, early ...

Inverter wiring method Inverter wiring method

First, the wiring of the main circuit 1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, the fragmented wires must be cleaned, and the fragmented wires may cause abnormalities. ...

Yaskawa servo motor - the selection step of servo control Yaskawa servo motor - the selection step of servo control

1. Determine mechanical specifications, load, rigidity and other parameters; 2. Confirm the action parameters, stroke, accuracy, acceleration and deceleration time, cycle, moving speed, etc.; 3. Select motor inertia, load inertia, motor axis conversion inertia, and rotor inertia; 4. Select the motor back ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top