Leveraging the expertise accumulated in the development of industrial sensors, such as area sensors and mapping sensors, Ottonix has developed the SFL series (standard) and SFLA series (high-performance) safety light curtain systems that comply with the leading international standards/regulations. The product has built-in finger/hand/human detection functions and various safety functions to respond sensitively to on-site conditions. In addition, atLiteCurtain-specific programs are available to focus on user convenience, real-time monitoring, automatic masking/white space settings.
Product structure conforms to international safety standards/rules (Class 4 ESPE (AOPD), SIL3, SIL CL3, Category 4, PLe, CE, UL certification, S-Mark)
It has three detection functions of fingers, hands, and hands-human body, and selects the appropriate form according to the environment
Built-in safety functions that can sensitively respond to on-site conditions and self-diagnosis functions
- Safety-related: interlock, OK, EDM, masking, overlay, blanking, reducing resolution, etc
- Self-diagnosis: including avoiding interference with each other, ambient light detection, fault sensor detection
Conversion of detection interval type (Short/Long type) and control output setting (NPN/PNP output) applicable to the installation environment
The operating status can be read by means of a 7-segment code indicator and an LED indicator. The top and bottom beam indicators make it easy to adjust the beam
The output indicator at the top shows the accepted/blocked and shielded status, eliminating the need for a rated indicator
4 non-safety outputs for a variety of applications (2 AUX, 2 lamps)
Use LightCurtain's dedicated software to set up specific functions
|
More on that
|
Ultrasonic flow sensor principle
Ultrasonic flow sensor is a new type of general-purpose time-difference multi-function ultrasonic sensor suitable for industrial environments, mainly using low-voltage multi-pulse balanced emission acceptance technology, which can be mainly applied to measure the flow of most clean and uniform liquids without large concentrations of suspended particles or gases.
|
|
Introduction to the Autonex differential pressure flow meter
The differential pressure flowmeter calculates the flow rate according to the differential pressure generated by the flow test piece installed in the pipeline, the known fluid conditions, and the size of the test piece and the pipeline.
The differential pressure flowmeter consists of a primary device (test piece) and a secondary device (differential pressure conversion and flow display) ...
|
|
Autonicus Safety Touchless Door Switches SFN Series
The SFN series of safety non-touch door switches reliably monitors the opening and closing of dedicated actuator doors by means of magnetic detection. This product can be connected to up to 30 units through a dedicated controller, and it can be used vertically and horizontally according to the installation environment, which improves the ease of use.
...
|
|
Autonics Single Display PID Temperature Controller TR1D Series New Product Released
The TR1D series has a high-speed sampling period of 50ms and a display accuracy of ±0.3% for more accurate temperature control. Simultaneous heating/cooling control is available to provide effective temperature control. With a width of only 22.5mm, the product minimizes the limitation of installation space and can be accessed with ...
|
|
Range of sensor applications – Autonex
The sensor is a very widely used detection device, which is used in environmental monitoring, traffic management, medical health, agriculture and animal husbandry, fire safety, manufacturing, aerospace, electronic products, and other fields. It can feel the information being measured, and can press the felt information ...
|
|
The difference between switching power supply and module power supply – Autonix
The two are not universal
Module power supplies are power supplies that can be mounted directly on a printed circuit board, and feature applications for application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog applications.
|
|
Ottonix's sensors contain:
Proximity switches
Proximity switches are a reliable and proven solution for the detection of correct and wrong contacts.
Photoelectric sensors
Photoelectric sensors use a pair of luminaires and receivers to detect distances and detect the presence of objects.
...
|
|
Causes and solutions for overheating or burning of AC contactor coils
Reasons: 1. The polar surface of the communication core is uneven or the demagnetization air gap is too large;
2. The double coil of DC operation derived from the communication contactor is overheated due to the fact that the normally closed interlocking contact is not released by welding;
3. The frequency of operation is too high;
4. Poor coil manufacturing or due to mechanical damage, absolute ...
|
|
Strain characteristics of pressure sensors
When measuring the strain of an element, the strain gauge can be directly glued to the component, but if you want to measure the force, pressure, acceleration and other signals, these physical quantities must first be converted into strain, and then measured with a strain gage, and the conversion process is more than when measuring directly. The first step in completing this transformation process ...
|
|
Autonex BD series laser displacement sensors
BD series laser displacement sensor can measure the thickness, width, horizontal difference, parallax, bending, and flatness of the target object by detecting the displacement.
Regardless of the color or material, the sensor provides accurate and reliable measurement results. Sensor head and amplifier unit ...
|
|
The difference between sensitivity, resolution, and accuracy of a sensor
sensitivity
Concept: It refers to the ratio of the change of output △y to the change of input △x in the case of steady-state operation of the sensor, that is, the ratio of the dimension of output and input.
Sensor sensitivity is the slope of the output-input characteristic curve. If the output and input of the sensor ...
|
|
Instrumentation Fault Diagnosis Method - Ottonix
1. Percussion hand pressure method
It is common to encounter the phenomenon of good and bad operation of the instrument, and most of this phenomenon is due to poor contact or virtual welding. In this case, percussion and hand pressure can be used.
The so-called "percussion" is to ...
|
|
Otonic photoswitch determination
1. Measurement of action interval; When the action piece approaches the sensing surface of the switch from the front, the interval between the action of the switch is the interval between the action of the switch, and the measured data should be within the parameters of the product.
2. The interval between exonerations ...
|
|
Advantages of digital load cells – Autonex
1. The transmission interval of the digital load cell is long, the communication speed is fast, and the anti-cheating effect is remarkable; The output signal of the traditional analog load cell is small, generally millivolt level, and the signal is still lost due to the damage of the cable resistance during the transmission process, and it is also very simple to be affected by the surrounding environment.
|
|
Autonix thermostat TZ4ST-24R features:
Dual PID auto-adjustment function
There are high-speed response modes and slow reaction modes in the PID function.
When you want to reach the desired value quickly, use the high-speed mode (PIDF mode)
When you want to minimize overshoot, use slow mode (PIDS mode)
...
|
|
Precautions for the use of photoelectric sensors
First, the selection of its primary consideration for the selection of three points: how wide the groove width should be; resolution (slit width); Fixation
1. The width of the slot, the detection object needs to pass through the slot of the slot-type optocoupler to block the infrared light, so the slot width of the photoelectric sensor should be wider than the detection object, and there should be a certain ...
|
|
Autonex BD series laser displacement sensors
BD series laser displacement sensor can measure the thickness, width, horizontal difference, parallax, twist and flatness of the target object by detecting the displacement.
Regardless of the color or data of the policy, the sensor can provide accurate and stable measurement results. Sensor head and amplifier unit ...
|
|
Introduction to Digital Fiber Optic Sensors
Digital fiber optic sensors convert measured objects into measurable optical signal sensors. Its working principle is to send the incident beam of the light source to the modulator through the optical fiber, and interact with the internal and external measurement parameters of the modulator to form a dimmable signal. Digital Fiber Optic Sensors ...
|
|
Load cell quality selection – Autonex
1. Observe whether the outside of the load cell is deformed or cracked. If there is any damage, please contact the manufacturer immediately.
2. Find the connection end of the sensor in the weighing controller, and measure the connection circuit of the sensor. The general excitation voltage (between EXC+ and EXC-) is 5-10V, and the output ...
|
|
Linear displacement sensor fault and treatment method - Autonics
1. If the electronic ruler is used for a long time, the seal is aging, there are many impurities, and the water mixture and oil will seriously affect the contact resistance of the brush, resulting in the continuous beating of the display. At this moment, it can be said that the electronic ruler of the linear displacement sensor is now damaged and needs to be replaced.
...
|
|