Yaskawa inverter model introduction - H1000 series

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

Yaskawa H1000 series is available in the following models

H1000 Series Heavy Load

1. CIMR-HB4A006FAA/FAC/FBC 1·5KW H1000 replaces G7 series

  2、CIMR-HB4A0075 30KW

  3、CIMR-HB4A0045AAA

  4、CIMR-HB4A0005FAA/FAC

  5、CIMR-HB4A0060

  6、CIMR-HB4A0003FAA

  7、HB4A0039FAA/FAC
Yaskawa inverter model introduction - H1000 series

More on that
Yaskawa servo motor - the selection step of servo control Yaskawa servo motor - the selection step of servo control

1. Determine mechanical specifications, load, rigidity and other parameters; 2. Confirm the action parameters, stroke, accuracy, acceleration and deceleration time, cycle, moving speed, etc.; 3. Select motor inertia, load inertia, motor axis conversion inertia, and rotor inertia; 4. Select the motor back ...

Yaskawa Electric - how to match the reducer according to the servo motor in practical application Yaskawa Electric - how to match the reducer according to the servo motor in practical application

1: Flange specification The cross-sectional size of the reducer is generally about the same as the cross-sectional size of the motor, and other parameters refer to the description of the selected brand, and the technical sample is generally marked with the selection steps and calculation examples. The specific model is indicated differently by brand. Usually in the output flange size or cross-sectional size ...

How to replace the bearing of Yaskawa servo motor? How to replace the bearing of Yaskawa servo motor?

1. Preparation before servo motor bearing replacement 1. Take the servo motor off the device position and make it in a state that is easy to operate in the working environment; 2. Touch the bearing by hand to determine whether it has been damaged or worn; 3. According to the requirements of the manufacturer, early ...

Yaskawa welding robot usage specifications Yaskawa welding robot usage specifications

Specifications for the use of Yaskawa welding robots.   Before the experiment. When experimenters enter the laboratory, they should wear tools and take protective measures. Prepare experiment-related equipment (welding masks, etc.) and consumables in advance. Check whether the shielding gas has gas ...

Yaskawa made its debut at the AMB - Robotics Innovation Trade Fair Yaskawa made its debut at the AMB - Robotics Innovation Trade Fair

As a long-standing and reliable supplier of automated metalworking solutions, Yaskawa will be exhibiting at AMB for the first time. Possible applications for the company's Motoman robots include tool handling, machining and stacking workpieces, and machine loading. At booth 6D50 in Hall 6, ...

Yaskawa robot servo motor burnout repair method Yaskawa robot servo motor burnout repair method

There are three main burning methods for common Yaskawa robot servo motors: overload, phase loss, and short circuit. 1. Overload: Open the servo motor of the industrial robot to observe. The color of the entire winding wire pack has become dark and black, the end strap is cracked, and the serious phase insulation and notch insulation are due to overheating.

Analysis of fault codes of Yaskawa inverter Analysis of fault codes of Yaskawa inverter

Analysis of the fault code of Yaskawa inverter, for reference only: OC Overcurrent The output current of the inverter exceeds the overcurrent detection value · GF grornd Favlt Grounding The ground current on the output side of the inverter exceeds 50% of the rated output current of the inverter ...

Yaskawa H1000 inverter overload oL2 fault Yaskawa H1000 inverter overload oL2 fault

There are two types of inverter overload faults: 1. If there is a problem with the load, it is a problem with the motor, such as the lack of oil in the bearing, the damage to the bearing, the burning of the winding, etc., and there is a situation that the power of the motor is small, and it is more difficult to drag the load. 2. It is the inverter ...

Detailed explanation of Yaskawa inverter fault codes Detailed explanation of Yaskawa inverter fault codes

1. The manifestation of the fault code of Yaskawa inverter When the Yaskawa inverter has a fault code, there are three manifestations: 1. Failure When a fault is detected, the following conditions occur. The LED operator has a text indicating the content of the fault, and the ALM refers to ...

How to deal with the occurrence of OL2 in Yaskawa inverter How to deal with the occurrence of OL2 in Yaskawa inverter

OL2 is the inverter overload alarm, check whether it is a real overload or a false overload. 1. Test whether the output current of the inverter exceeds the rated current of the inverter, if it exceeds it, it may be the mechanical reason, if it does not exceed the inverter detection circuit is broken, and the false overload is reported. ...

Yaskawa servo motor - how does PLC control servo motor? Yaskawa servo motor - how does PLC control servo motor?

Before answering this question, we must first understand the purpose of servo motors, compared with ordinary motors, servo motors are mainly used for precise positioning, so what we usually call the control servo is actually the position control of the servo motor. In fact, the servo motor also uses two other kinds of ...

How to cancel the Yaskawa robot collision alarm? How to cancel the Yaskawa robot collision alarm?

1. Enter the management mode and click on the robot. 2. Click on the collision detection level, enter the designated page, select the collision detection file number, enter 9, and press enter. 3. Change the function from valid to invalid. After the robot action is restored, it can be changed back to effective. ...

How to wire Yaskawa servo motor B1B2? How to wire Yaskawa servo motor B1B2?

1. First of all, connect the terminal block of Yaskawa servo B1B2, in which the B1 terminal receives the power supply and the B2 terminal receives the signal; 2. Then, connect the terminal block of Yaskawa servo B1B2, wherein B1 terminal receives power supply, and B2 terminal receives signal; 3. After the wiring is completed, ...

Common faults of Yaskawa inverters Common faults of Yaskawa inverters

The switching power supply is damaged Switching power supply damage is the most common fault of many inverters, usually caused by short circuit in the load of switching power supply, in the design of switching power supply circuits of many inverters, Yaskawa inverter is relatively successful. OH failure Old...

MindMotion Technology joined hands with Yaskawa Shougang to appear on the CCTV screen again MindMotion Technology joined hands with Yaskawa Shougang to appear on the CCTV screen again

Recently, after appearing on CCTV news during the Beijing Winter Olympics, MindMotion Technology and Yaskawa Shougang appeared on the CCTV stage again, demonstrating the application achievements of the two sides in jointly building an advanced manufacturing cluster in the field of intelligent manufacturing and enhancing the competitiveness of the industrial chain and supply chain. It was reported in the news that the new ...

Yaskawa V1000 inverter alarm CPF06 fault maintenance after powering on Yaskawa V1000 inverter alarm CPF06 fault maintenance after powering on

1. Fault phenomenon: The fault phenomenon is the alarm CPF06 after power-on, which cannot be reset. Second, the maintenance method: The explanation for the CPF06 fault reported by Yaskawa V1000 inverter is: EEPROM data is abnormal. Generally, it is possible to restart the inverter or perform initialization ( A1-03=2220 ) ...

Replacement of Yaskawa inverter spare parts Replacement of Yaskawa inverter spare parts

The inverter is composed of a variety of components, some of which will gradually decline and age after the temporary task, which is also an important cause of the failure of the inverter, in order to ensure the temporary normal operation of the equipment, the following devices should be replaced on a regular basis: 2.1 Cooling fan Frequency converters ...

Fault codes for Yaskawa servo drives Fault codes for Yaskawa servo drives

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

The frequency of the frequency converter is given in a given way The frequency of the frequency converter is given in a given way

1. The simplest way to give the frequency of the inverter is to complete it through the operation panel, and users can usually change the set frequency directly through the potentiometer, digital key or rising and descending keys on the generator panel. The biggest advantage given by the operator panel is that it is simple, ...

Yaskawa inverter - maintenance method of low-voltage inverter Yaskawa inverter - maintenance method of low-voltage inverter

1. Countermeasures to the overheating problem of inverter 1. For places where the operating environment temperature of the inverter is high, it is recommended to reduce the temperature of the inverter and strengthen cooling and ventilation; 2. Increase the frequency of regular maintenance of inverter fans, air ducts, etc., so as to improve the operating environment of the inverter, so that the inverter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top