Reynolds servo motor selection steps

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

According to the requirements of the operating conditions, the appropriate load inertia accounting formula is selected to calculate the load inertia of the organization.

According to the load inertia and servo motor inertia, the appropriate servo motor standard is selected.

Combined with the inertia and load inertia of the primary servo motor, the acceleration torque and deceleration torque are calculated.

                              Reynolds servo motor selection steps

Clarify the requirements of the motion conditions of the load tissue, that is, the speed of acceleration/deceleration, the speed of movement, the component of the tissue, the movement method of the tissue, etc.

The load torque is calculated according to the load component, configuration method, friction coefficient, and operating efficiency.

The maximum output torque of the primary servo motor must be greater than the acceleration torque + load torque; If the conditions are not met, other types of accounting verification must be selected until the requirements are met.

According to the load torque, acceleration torque, deceleration torque and persistence torque, the successive instantaneous torque is calculated.

The rated torque of the primary servo motor must be greater than the instantaneous torque, if it does not meet the conditions, it must be verified by other types of accounting until it meets the requirements.

The end is selected.

More on that
The way to set the parameters of the inverter - Reynolds The way to set the parameters of the inverter - Reynolds

There are many setting parameters of the inverter, and each parameter has a certain range of choice, and the inverter can not work normally due to the improper setting of a single parameter in use, therefore, the relevant parameters must be set correctly. ...

The role of frequency conversion technology in work equipment - Reynolds The role of frequency conversion technology in work equipment - Reynolds

Because inverters are widely used, there are many differences in the corresponding types and specifications. We are broadly divided into two categories: voltage and current. The current type of inverter products is characterized by the use of a large inductor as the energy storage link in the middle DC link, and the reactive power will be buffered by this inductor. ...

What inverter to choose what occasion - Reynolds What inverter to choose what occasion - Reynolds

We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter. When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a ...

How to control the torque of the inverter vector according to the system - Reynolds How to control the torque of the inverter vector according to the system - Reynolds

A brief introduction to the progress of the inverter in terms of torque: This function adds the output voltage of the inverter so that the output torque of the motor is proportional to the square of the voltage, so as to improve the output torque of the motor. Improve the skill of insufficient torque at low speed output of the motor, and use the "vector manipulation" ...

General Purpose Inverter Repair Inspection – Reynolds General Purpose Inverter Repair Inspection – Reynolds

The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...

Advantages of the inverter vector control system - Reynolds Advantages of the inverter vector control system - Reynolds

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

Introducing the Reynolds JJR5000 series of soft starters Introducing the Reynolds JJR5000 series of soft starters

Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, which is a new type of starting equipment at the current level. This product can limit the starting current of the asynchronous motor when it starts, and is widely used in fans, ...

Frequency converters need to be replaced regularly – Reynolds Frequency converters need to be replaced regularly – Reynolds

The inverter is composed of many electronic parts, such as semiconductor components, etc., in the application and protection involves the replacement of a related component, because of the composition or physical characteristics of the inverter, it will deteriorate in a certain period of time, which will reduce the characteristics of the inverter, and even ...

The external configuration of the inverter is solved - Reynolds The external configuration of the inverter is solved - Reynolds

With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...

The breaking capacity of the industrial control appliance switch The breaking capacity of the industrial control appliance switch

Assuming Icu=60KA, then when a faulty current of 60KA is generated in the line, the circuit breaker can safely cut off the circuit without abnormal conditions such as contact welding and blasting. Pay attention to the extreme breaking ...

The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy

Shanghai Reynolds Technology Co., Ltd. is an enterprise specializing in the design and production of high and low voltage soft starters, high and low voltage variable frequency speed regulation, intelligent electrical, new energy electrical and high and low voltage power transmission and transformation equipment, which are widely used in electric power, metallurgy, petroleum and petrochemical, military, mining, chemical industry, ...

Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.

Frequency conversion cabinet external conduit wiring method - Reynolds Frequency conversion cabinet external conduit wiring method - Reynolds

When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods: 1. Kim ...

The cause of the damage of the inverter - Reynolds inverter The cause of the damage of the inverter - Reynolds inverter

What are the causes of inverter damage? First, the heat dissipation of the inverter is not good In fact, we all know that too high a temperature can have a damaging effect on any device, just like the human brain, too high a temperature can also burn out the brain ...

Inverter dust handling – Reynolds inverters Inverter dust handling – Reynolds inverters

1. Plan a special inverter room: When the power of the inverter used is large or the number is large, a special inverter room can be planned. The doors, windows and cable holes in the room should be sealed to prevent dust from entering; It is necessary to plan air filtration equipment and circulation channels to adhere to the normal circulation of indoor air ...

Renault is available in a variety of product ranges Renault is available in a variety of product ranges

JJR1000系列:   JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1320;JJR1400;JJR1500;JJR1600 ...

Reynolds frequency converters RNB1000 series E.ITE fault codes Reynolds frequency converters RNB1000 series E.ITE fault codes

Reynolds inverter problem code: E.ITE Reynolds inverter problem phenomenon/type: Problems with the current sensing circuit Possible causes of Reynolds inverter problems: 1. Poor contact of the control board connector 2. The auxiliary power supply is damaged 3. Hall ...

Selection of large fan inverter in the factory - Reynolds Selection of large fan inverter in the factory - Reynolds

First, select from the inverter "software". The reason why the factory chooses the inverter to work together with the fan is that it is hoped that the automation and intelligent design of the inverter technology can improve the speed regulation mode of the fan, and reduce the wasted energy consumption, which not only improves the wind efficiency.

The reason why the inverter burns the power supply inlet end - Reynolds The reason why the inverter burns the power supply inlet end - Reynolds

1. It is necessary to consider the touch and current size of the incoming terminal, if the terminal standard is small, perhaps the conductive function of the terminal is poor, which will directly cause the current carrying capacity of the terminal to be small and heated. 2. The inlet at the end of the inlet line must be pressed well and the like, if it is not pressed, it may cause ...

Reynolds inverter overhaul process Reynolds inverter overhaul process

1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top